Siemens DTU3005-B Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Networking Siemens DTU3005-B. Siemens DTU3005-B Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Trip Units and Accessories

SB Encased Systems Breakers,Trip Units and AccessoriesSelection and Application GuideOctober1,1999

Strona 2 - Table of Contents

9SB-EC Trip UnitsTwo types of interchangeable trip units for the SB Encased SystemsBreakers are available. The basic type “TL” Trip Unit features a fu

Strona 3 - General Information

SB-EC Menu StructureFront Panel Menu Structure10MAIN MENU➡ SYSTEM CONFIGPROTECTIVEMETERINGCOMMUNICATIONSLOGSOPERATIONSSECURITYSYSTEM CONFIG➡ VIEW CONF

Strona 4

11SB-ECTrip Unit AccessoriesCatalog Number Input VoltageSBEPS 120 VACSBEPS24 24 VDC and 48 VDCTable F: SB-EC External Power SupplyTable

Strona 5

12Type “TL”Trip UnitsSYSTEMCHECKContinuousLongTimeDelay%lrRating Pluglr = 4000AShortTimeDelayxlrSecs@8 x lrShortTimePickup81.522.533.54567.3.07.1.15.2

Strona 6

13Type“TL”Trip Unit AccessoriesTable M: Rating Plugs for SB-EC and Type “TL” Trip UnitsSelect the proper Rating Plug based on the maximum continuous c

Strona 7 - Non-Automatic Switches

Internal and External Accessories14Table N: Electrical OperatorsElectric Operators function to automatically charge the SB break-er’s stored energy me

Strona 8

15Internal and External AccessoriesShunt TripsAllows the breaker to be opened from a remote location. Includedis an auxiliary switch for remote indica

Strona 9

Internal and External Accessories16Voltage Catalog AC DC Number120 — SBDMR120—24SBDMR24—48SBDMR48— 125 SBDMR125Alarm Relay

Strona 10 - SB-EC Trip Units

17Internal and External AccessoriesCatalog NumberKISB (Kirk)SISB (Superior)DrawoutFixed Breaker BreakerFrame Catalog Catalog Sizes Num

Strona 11 - SB-EC Menu Structure

Test KitFor field testing the SB Encased System Breaker. The test kit cantest the following breaker functions by phase: Time Short Time Instant

Strona 12 - SB-ECTrip Unit Accessories

Table of ContentsGeneral Information 2-3Description Stationary and Moveable Drawout Elements 4How to Order SB Encased Systems Breakers 5Frames 6SB Cir

Strona 13 - Type “TL”Trip Units

1Alternate cable lengths available by special order. Contact your local sales office for details.Multiplexer/Translator (MT)The Multiplexer/Translator

Strona 14 - Type“TL”Trip Unit Accessories

External Accessories and ACCESS™Communications SystemSB Breaker CommunicationAll SB Circuit Breaker trip unit feature levels of communication:Zone Sel

Strona 15

External Accessories ACCESS™Communications SystemThe MTCSB cable is used to connect an MTA or MTZ to an EPSBexpansion plug via the SB breaker seconda

Strona 16

Outline Dimension Drawing1200A Stationary Drawout ElementLC4X Ø.4383.25Left Cradle Plate ShownCut Away For Clarity3.502X 5.00Provide Clearance Holes F

Strona 17

Outline Dimension Drawing1200A Stationary Drawout ElementOptional RearMounting Surface1.304X 2.50Provide Clearance Holes For #8-32 ScrewsWhen Using Re

Strona 18

Outline Dimension Drawing1200A Moveable Drawout Element3X Ø 1.251.742.13.20.944.564X.592.842X.442.844.56.9420.50Overall10.256.8813.75Overall4.592.872

Strona 19 - Communications

Outline Dimension Drawing1200A Moveable Drawout Element7.7515.50Front Cover LocationShown Provides MinimumClearance With Breaker.75Breaker TestPositio

Strona 20

Outline Dimension Drawing1200A Fixed-Mounted1.1311.1311.383.371.00Typ.See Detail A11.6312.1315.505.005.00Ø.34 HolesTyp.2.252.50.09Detail A – 1/1 Scale

Strona 21 - Communications System

Outline Dimension Drawing1200A Fixed-Mounted7.8211.00.95Typ.Clearance for Handle RotationØ .34 HolesTyp.90°Max..50Typ.1.75Typ.3X Ø 1.252X .941.742.13

Strona 22 - ACCESS Communications:

Outline Dimension Drawing2000A Stationary Drawout ElementLCLC2X 2.502X 9.75CLProvide Clearance Holes For #8-32 ScrewsWhen Using Rear Flange Mounting S

Strona 23 - Outline Dimension Drawing

General InformationNOTE: For more information on other standard and optionaltrip unit features, see Siemens Electronic Trip Units for SBEncased System

Strona 24

Outline Dimension Drawing2000A Stationary Drawout Element4X Top4X Bottom4X Top4X BottomØ .438 Optional Mounting Holes8.7517.505.005.00.50Lifting Point

Strona 25

Outline Dimension Drawing2000A Moveable Drawout Element7.7515.50Front Cover LocationShown Provides MinimumClearance With Breaker.75Breaker TestPositio

Strona 26 - Side View

Outline Dimension Drawing2000A Moveable Drawout Element31

Strona 27 - 1200A Fixed-Mounted

32Outline Dimension Drawing2000A Fixed-MountedLC7.82Handle Clearance Rotation2.872X 2.5090° Max.24 Ø .39 Holes1.75Typ.2X 7.121.75.881.133.37.75Typ.11

Strona 28 - Front View

Outline Dimension Drawing3200A,4000A,and 5000A Stationary Drawout ElementStationary Drawout ElementRear View DimensionsRear View4X 7.504X 5.004X 4.002

Strona 29

Outline Dimension Drawing3200A,4000A,and 5000A Moveable Drawout ElementLocationFrame Size3200 4000/5000AB7.5015.0011.5023.0016.00.7514.731.61Breaker T

Strona 30 - (Next Page)

Outline Dimension Drawing3200A,4000A,and 5000A Moveable Drawout Element17.50BAOverall35.00OverallFront ViewOfBreakerOfBreaker3.455.713.455.712.872.878

Strona 31

Outline Dimension Drawing3200A Fixed-Mounted 4.915.693.9810.25R .12Typ..7514.00R .12Typ.9.134.54Front View(Escutcheon Dimensions)5.00Typ.Side View15.1

Strona 32

Outline Dimension Drawing3200A Fixed-Mounted15.505.00 5.00.75.6311.1311.3811.6312.1312.75Top ViewFront View14.1210.005.002.75Typ.30X Ø .41 Holes3.501.

Strona 33 - Detail A

Outline Dimension Drawing4000A and 5000A Fixed-MountedR .12Typ.R .12Typ.8.91 5.683.9810.253.50 16.509.134.54Front View(Escutcheon Dimensions)1.25Typ..

Strona 34

General InformationCompact SizeFor space-limited installations, the 1200A and 2000A frames offera common width of 15 1/2 inches, a common depth of onl

Strona 35

Outline Dimension Drawing4000A and 5000A Fixed-Mounted23.5020.0012.505.00 .50Typ.1.50Typ..87.6311.1311.3811.6312.1312.75Top View8X Ø .44 Mounting Hole

Strona 36

40Internal AccessoriesElectric MotorOperatorand Local Electric Close<LT2>Remote Close +NONC<LT3>Local Electric CloseLOCAL ELECTRIC CLOSE

Strona 37

41Electrical Schematics2448121620 28 323632176511109151413191817232221272625313029353433ALARMTRIP<RT12><RT10><RT11><RT9>+

Strona 38 - 8 -16 X 2.75 (Min.) Bolts

Electrical Schematics<LT9> UVR+UVRCoil<LT10> UVR–MonitoredSource+ –External ConnectionsInternal Breaker ConnectionsUnd

Strona 39

Electrical SchematicsShunt Trip<LT7> Remote Open-Closed Indication<LT8> Coil - (Common) COMNC <ST>NO<LT6> Coil+“B” Typ

Strona 40 - 4 (Min.) Bolts

44Electrical Schematics(Cable to Multiplexer/Translator, use Cat.No. MTCS-XX, where XX = length in feet.To Multiplexer Translator<LB10> Green&

Strona 41 - External Connections

SB Solenoid Coil ResistancesSHUNT TRIP SOLENOID:SHUNT TRIP PLUNGER O.D. = 0.310 INCH+/- 5% @ 20 degrees C12 VDC - 3.6 ohms 120 VAC - 79.6 ohms24 VCD -

Strona 42

Insulated Case Circuit Breakers -Guide Form Specification SPECIFICATIONS:1.01 STANDARDSA. The insulated case circuit breakers and all component

Strona 43 - Electrical Schematics

Insulated Case Circuit Breakers -Guide Form Specification H. The continuous ampere rating of the breaker shall be determined by a rating plug, which s

Strona 44

Insulated Case Circuit Breakers -Guide Form Specification Z. When current harmonic analysis is specified, the trip unit shall be equipped to provide

Strona 45

Description Stationary and Moveable Drawout ElementsSimplified Minimum Depth Drawout MechanismThe two elements of a drawout constructed SB Encased Sys

Strona 46 - SB Solenoid Coil Resistances

Siemens Energy & Automation, Inc. Distribution Products Division3333 Old Milton ParkwayAlpharetta, GA 30005© Siemens Energy & Automation,

Strona 47 - Guide Form Specification

5How to OrderSB Encased Systems Breakers1ExampleCatalog Description Number Example Catalog Number Explanation1. Frames SBS2016DV This catalo

Strona 48

6FramesTable A: Circuit Breaker FramesSBA Alternate Interrupting Rating1Drawout Breaker Element 2Breaker Frame Fixed Mounted

Strona 49

Ratings,Stationary Drawouts and PowerConnectorsUL Symmetrical RMS Amperes Interrupting Ratings (kA)Optional Ratings and Breaker Frame SizeApplication

Strona 50 - 1.800.964.4114

8Ratings,Stationary Drawouts and PowerConnectorsTable C: Bus Connectors and Pressure Wire Connectors T-Connectors 1For rear busconnected fixed mounted

Komentarze do niniejszej Instrukcji

Brak uwag