2000591-001 Introduction 7
ANG_DN Specifications, Continued
The following Table should be used when evaluating or selecting cable for an
existing or new installation.
Cable Type Vendors & P/N Installation Notes
Fiber Optic
MM 62.5/125; 4 Fiber Conductors
Required for TX/RX Redundancy
SAA P/N 1270002-002
Industry Available from
Multiple Vendors
New Installation as an al-
ternative to copper cable
Max distance from Analyzer
to Hub or between Hubs
1520 meters (5000 ft)
2- Conductor Copper Wire SAA P/N 1686002-001
Belden P/N 9182
For
Belden Armored Cable
Order
SAA P/N 1680000-002
Recommended for Single
Channel
Max distance from Analyzer
to Hub or between Hubs
1520 meters (5000 ft)
4-Conductor Copper Wire SAA P/N 1681000-003
Belden P/N SSD1743
Recommended for Dual
Channel
Max distance from Analyzer
to Hub or between Hubs
1520 meters (5000 ft)
Ethernet Cat 5 STP Shielded
Twisted pair or Cat. 5 UTP in Con-
duit
SAA P/N 1681003-006
Industry Available from
Multiple Vendors
Recommended for short
distances or within shelters.
Max distance from analyzer
to hub or between hubs 600
meters (2000 ft)
ANG Cable Types