DSB75 Development Support Board Rev. B1 Hardware Description
Strictly confidential / Released
s
DSB75_hd_v08 Page 33 of 94 29.09.2005
As the X202 interface has only four lines, you may need a customized adapter cable for the
RS-232 connection. This is useful, for example, if your application also requires the lines
DSR, DCD, RING. In such a case it is recommended to use the following pin assignment:
1
5
9
6
9 pole Sub-D
on PC side
(female)
1
5
9
6
9 pole Sub-D
on DSB75 side
(male)
1
2 RXD
3 TXD
4
5 GND
6
7 RTS
8 CTS
9
1
2
3
4
5
6
7
8
9
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
RING
Figure 13: Recommended adapter cable from PC to COM2 on DSB75
3.5.3 Debug Interface (COM3)
The debug interface COM3 (X205) of the DSB75 is reserved for Siemens internal software
debugging. It is a two wire interface with data lines only.
A level converter D201 adapts and inverts the V.24 signals (2.9V level) from the GSM
module to RS-232C level.
The output lines are switched off (high impedance) if the GSM module is in POWER DOWN
mode.
The ASC2 lines of the GSM module are used by default as GPIOs (see section 3.3)
Table 11: Pin assignment of debug interface COM3 (X205)
Pin Name I/O Description X100 signal
name
Config.
switches
Remark
2 RXD O Receive Data RXD2_GPIO9 S458:1
3 TXD I Transmit Data TXD2_GPIO10 S459:1
5 GND - Ground GND
1, 4, 6,
7, 8, 9
nc
nc= not connected