Level measurement
Continuous level measurement — Ultrasonic controllers
HydroRanger 200
4/159
Siemens FI 01 · 2014
Technical specifications
1)
All relays certified for use with equipment that fails in a state at or under the
rated maximums of the relays
2)
This model is level control only; no open channel flow, differential level or
volume conversion functions
3)
Program range is defined as the empty distance to the face of the
transducer plus any range extension
4)
Maximum power consumption is listed
5)
EMC performance available upon request
Mode of operation
Measuring principle Ultrasonic level measurement
Measuring range
0.3 ... 15 m (1 ... 50 ft),
transducer dependent
Measuring points 1 or 2
Input
Analog 0 ... 20 mA or 4 ... 20 mA,
from alternate device, scaleable
(6 relay model)
Discrete
10 ... 50 V DC switching level
Logical 0 0.5 V DC
Logical 1 = 10 ... 50 V DC
Max. 3 mA
Output
EchoMax transducer 44 kHz
Ultrasonic transducer Compatible transducers: ST-H
and EchoMax series XPS-10,
XPS 15/15F, and XRS-5
Relays
1)
Rating 5 A at 250 V AC,
non-inductive
• Model with 1 relay
2)
1 SPST Form A
• Model with 3 relays
2)
2 SPST Form A/1 SPDT Form C
• Model with 6 relays 4 SPST Form A/2 SPDT Form C
mA output 0 ... 20 mA or 4 ... 20 mA
• Max. load 750 Ω, isolated
Resolution 0.1 % of range
Accuracy
Error in measurement 0.25 % of range or 6 mm
(0.24 inch), whichever is greater
Resolution 0.1 % of measuring range or
2 mm (0.08 inch), whichever is
greater
3)
Temperature compensation • -50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor in
transducer
• External TS-3 temperature
sensor (optional)
• Programmable fixed
temperature values
Rated operating conditions
Installation conditions
Location Indoor / outdoor
• Installation category
II
• Pollution degree 4
Ambient conditions
• Ambient temperature (enclosure) -20 ... +50 °C (-4 ... +122 °F)
Design
Weight
• Wall mount 1.37 kg (3.02 lb)
• Panel mount 1.50 kg (3.31 lb)
Material (enclosure) Polycarbonate
Degree of protection (enclosure)
• Wall mount IP65/Type 4X/NEMA 4X
• Panel mount IP54/Type 3/NEMA 3
Cable
• Transducer and mA output signal 2-core copper conductor, twisted,
shielded, 300 Vrms, 0.82 mm²
(18 AWG), Belden 8 760 or
equivalent is acceptable
• Max. separation between
transducer and transceiver
365 m (1 200 ft)
Displays and controls 100 x 40 mm (4 x 1.5 inch)
multi-block LCD with backlighting
Programming Programming using handheld
programmer or via PC with
SIMATIC PDM software
Power supply
4)
AC version 100 ... 230 V AC ± 15 %,
50/60 Hz, 36 VA (17 W)
DC version
12 ... 30 V DC (20 W)
Certificates and approvals • CE, C-TICK
5)
• Lloyd's Register of Shipping
• ABS Type Approval
•FM, CSA
US/C
, UL listed
•CSA
US/C
Class I, Div. 2,
Groups A, B, C, and D, Class II,
Div. 2, Groups F and G, Class III
(wall mount only)
• MCERTS Class 3 approved for
Open Channel Flow
Communication
• RS 232 with Modbus RTU or
ASCII via RJ-11 connector
• RS 485 with Modbus RTU or
ASCII via terminal blocks
• Optional: SmartLinx cards for
- PROFIBUS DP
- DeviceNet
- Allen-Bradley Remote I/O
© Siemens AG 2014