Siemens KDN Series Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Networking Siemens KDN Series. Siemens KDN Series Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 382
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
To be the partner of your success
CONTENTS
MT5000/4000 SERIES HMI AND PLC CONNECTING GUIDE ........................................................- 1 -
1
SERIAL COMMUNICATION PIN DEFINITION ............................................................................................ - 1 -
2
PRINTER CONNECTING CABLE DIAGRAM ............................................................................................. - 3 -
2.1 Serial Interface Printer Cable ........................................................................................................- 3 -
2.2 Recommend Optional printer ........................................................................................................- 5 -
3
DOWNLOAD CABLE DIAGRAM .............................................................................................................. - 6 -
3.1 Download by Serial Port ...............................................................................................................- 6 -
3.2 Download by USB ........................................................................................................................- 6 -
3.3 Download by Network Ethernet ....................................................................................................- 6 -
4
COMMUNICATION SETTINGS AND GUIDE OF HMI CONNECTING WITH CONTROLLER ............................ - 8 -
4.1 ABB Corporation ...........................................................................................................................- 8 -
4.2 Allen-Bradley ..............................................................................................................................- 12 -
4.3 ACS-Tech80 Motion Controller ..................................................................................................- 24 -
4.4 ADAM .........................................................................................................................................- 26 -
4.5 AysjNet ........................................................................................................................................- 28 -
4.6 BACnet MS/TP ...........................................................................................................................- 29 -
4.7 Baldor NextMove ES (Motion Controller) ..................................................................................- 34 -
4.8 Barcode .......................................................................................................................................- 36 -
4.9 Baumuller
....................................................................................................................................- 37 -
4.10 Bosch Rexroth KVFC+ (Inverter) .............................................................................................- 38 -
4.11 Bosch Rexroth ...........................................................................................................................- 40 -
4.12 Bosch Rexroth Ethernet.............................................................................................................- 48 -
4.13 CANOpen Node Slave ..............................................................................................................- 54 -
4.14 Cimon ........................................................................................................................................- 61 -
4.15 Danfoss Inverter ........................................................................................................................- 63 -
4.16 Delta Corporation ......................................................................................................................- 69 -
4.17 Delta (Temperature Controller) .................................................................................................- 72 -
4.18 ENDA ........................................................................................................................................- 78 -
4.19 Emerson NetWork Power ..........................................................................................................- 80 -
4.20 Epower ......................................................................................................................................- 84 -
4.21 Facon Corporation .....................................................................................................................- 86 -
4.22 Fuji SPB ....................................................................................................................................- 91 -
4.23 GE Fanuc Automation Inc. ........................................................................................................- 93 -
4.24 HAIWELL ............................................................................................................................... - 102 -
4.25 HanG ....................................................................................................................................... - 104 -
4.26 Hitachi Inverter ....................................................................................................................... - 105 -
4.27 Hitachi IES Co., Ltd ................................................................................................................ - 107 -
4.28 Hollysys Corporation ................................................................................................
.............. - 114 -
4.29 HuaDA HD-JZ06 ..................................................................................................................... - 117 -
4.30 IDEC Corporation ................................................................................................................... - 119 -
4.31 Inovance Electric Corporation ................................................................................................. - 121 -
Przeglądanie stron 0
1 2 3 4 5 6 ... 381 382

Podsumowanie treści

Strona 1 - CONTENTS

To be the partner of your success CONTENTS MT5000/4000 SERIES HMI AND PLC CONNECTING GUIDE ...- 1

Strona 2

3 Download cable diagram HMI Ethernet terminalRJ45Ethernet Hub or SwitchRJ451 RX+(orange,white)4 BD4+ (bule)5 BD4- (bule,white)2 RX- (orange)3 T

Strona 3

4 Communication settings and guide of HMI connecting with controller CSE925 CPX772 CPX782 CPX928 CPX935 CGR772 CGR935 PACSystem RX7i CPE010 CPE020 CRE

Strona 4

4 Communication settings and guide of HMI connecting with controller GE SNP-X Protocol RS422 Communication NOTE: Set matching communication paramete

Strona 5

4 Communication settings and guide of HMI connecting with controller ◎Network Communication Setting HMI: PLC: - 99 -

Strona 6

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes System SC01-3

Strona 7

4 Communication settings and guide of HMI connecting with controller Controller VersaMax terminal9 pin D-SUB (male)HMI terminal9pin D-SUB female/male

Strona 8

4 Communication settings and guide of HMI connecting with controller HMI terminal9pin D-SUB female/male1 Rx-9 Tx+4Tx-12 SDA-7 GND13 SDB+5 GND6 Rx+11 R

Strona 9 - 3 Download Cable Diagram

4 Communication settings and guide of HMI connecting with controller Haiwell RS485 communication ◎Supported Device Device Bit Address Word Address

Strona 10 - Ethernet Hub or Switch

4 Communication settings and guide of HMI connecting with controller Analog Input ------- AI0-31 DD ◎Cable Diagram Haiwell RS232 communication cable C

Strona 11

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Password ---

Strona 12 - RS232

4 Communication settings and guide of HMI connecting with controller ◎Communication Setting HMI default communication parameter: 4800, 7, none, 1; sta

Strona 13

4 Communication settings and guide of HMI connecting with controller 4 Communication Settings and guide of HMI connecting with Controller Note:Do not

Strona 14

4 Communication settings and guide of HMI connecting with controller Recount Motor Con ------ (0B)Recount Motor Cons 0 D Write only Store EEPROM --

Strona 15 - 4.2 Allen-Bradley

4 Communication settings and guide of HMI connecting with controller H-1002(CPU2-10H) COMM-2H EH-150 EH-150(EH-CPU104) EH-150(EH-CPU104A) EH-150(EH-CP

Strona 16 - ◎Serial System Communication

4 Communication settings and guide of HMI connecting with controller EH-150 EH-150(EH-CPU104) Serial port 1 on CPU Serial port 2 on CPU MICRO-EH

Strona 17

4 Communication settings and guide of HMI connecting with controller HITACHI EHV Series Ethernet (TCP Slave) HMI Setting ◎Supported Device Hitachi

Strona 18

4 Communication settings and guide of HMI connecting with controller Internal Output R 0000-FFFF ------ HHHH Data Area M 0000-FFFF ------ HHHH F

Strona 19 - RSLogix5000 software setting

4 Communication settings and guide of HMI connecting with controller   The transmission speed of port 1 will be set with DIP 3, 4 switches o 3 on, 4

Strona 20

4 Communication settings and guide of HMI connecting with controller DW ------ DW 0-FFF HHH FW ------ FW 0-BFF HHH SW ------ SW 0-BF HH ZW -----

Strona 21

4 Communication settings and guide of HMI connecting with controller Hitachi EH-A23DR RS232 communication cable HMI terminal9pin D-SUB female/malecom2

Strona 22

4 Communication settings and guide of HMI connecting with controller Series CPU Link Module COMM Type Parameter Cable Hollysys LM LM3109 RS232 on

Strona 23

4 Communication settings and guide of HMI connecting with controller HMI Setting Note:In the dual redundancy system, just set one of IP addresses in

Strona 24

4 Communication settings and guide of HMI connecting with controller RS485-2 ABB AC500 protocol: Default communication parameters 9600, 8, none, 1;

Strona 25

4 Communication settings and guide of HMI connecting with controller ◎Cable Diagram Hollysys LM RS232 communication cable Controller port1 terminal9 p

Strona 26 - PLC-5 RS232 cable diagram

4 Communication settings and guide of HMI connecting with controller RS485 communication ◎Supported Device Device Bit Address Word Address Fo

Strona 27

4 Communication settings and guide of HMI connecting with controller RS485 Port HMI terminal9pin D-SUB female/male1 RX-6 RX+5 GNDcom0/com1Controller t

Strona 28

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Internal Rela

Strona 29 - ADMA-4015

4 Communication settings and guide of HMI connecting with controller com0/com1HMI terminal9pin D-SUB female/maleController terminal8 pin Mini Din (mal

Strona 30

4 Communication settings and guide of HMI connecting with controller RS422 RS485 PLC Setting - 122 -

Strona 31 - 4.5 AysjNet

4 Communication settings and guide of HMI connecting with controller You should put off JP0, if communication on the COM0, RS485. You should set D8126

Strona 32 - BACnet MS/TP

4 Communication settings and guide of HMI connecting with controller Device Bit Address Word Address Format Notes Input Relay X 000-177 ------ O

Strona 33

4 Communication settings and guide of HMI connecting with controller com0/com1Controller COM1RS485 terminalHMI terminal9pin D-SUB female/male1 RX-6 RX

Strona 34

4 Communication settings and guide of HMI connecting with controller PLC Setting 1. The PLC has two ports: port0 and port1, port1 support RS232 and R

Strona 35 - BACnet IP protocol

4 Communication settings and guide of HMI connecting with controller PLC Settings Related parameters settings refer to the communication equipment spe

Strona 36

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes C_bit C_bit 0-25

Strona 37 - Baldor NextMove ES

4 Communication settings and guide of HMI connecting with controller RS232 communication cable HMI terminal9pin D-SUB female/maleController port08 pi

Strona 38

4 Communication settings and guide of HMI connecting with controller Analog inputs ------ AIW0-30 DD Analog outputs ------ AQW0-30 DD Intern

Strona 39 - 4.8 Barcode

4 Communication settings and guide of HMI connecting with controller 4.34 Kinco Corporation ◎Serial Communication Series CPU Link Module Driver Ki

Strona 40 - Baumuller

4 Communication settings and guide of HMI connecting with controller K306-24DR K306-24AT K306-24AR K306EX-24AT K306EX-24AR K308-40AR K308-40AT K308-40

Strona 41

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Discrete inpu

Strona 42

4 Communication settings and guide of HMI connecting with controller Controller terminal9 pin D-SUB (male)com23 TX2 RX5 GND8 TX7 RX5 GNDcom0/com1HMI t

Strona 43 - 4.11 Bosch Rexroth

4 Communication settings and guide of HMI connecting with controller RS422 on the CPU unit ◎System configuration Series CPU Link Module COMM Type Para

Strona 44 - L40 Hardware Settings

4 Communication settings and guide of HMI connecting with controller ◎Supported Device EB-MOD2P-01 Device Bit Address Word Address Format Notes Int

Strona 45 - PPC-R software setting

4 Communication settings and guide of HMI connecting with controller e.g. :3X_BIT1.0~~1.15--------------------PQW256(binary) PLC software setting Set

Strona 46 - L40 software setting

4 Communication settings and guide of HMI connecting with controller ABB AC500 Device Bit Address Word Address Format PLC Register MB0.0—8191.7 -

Strona 47

4 Communication settings and guide of HMI connecting with controller NOTE: the address of DP can’t be the same as MPI’s. Double click the address num

Strona 48

4 Communication settings and guide of HMI connecting with controller (1) Setting ID of Profibus by switching 8-bit Dip(DIP1 is lowest bit, DIP8 is hi

Strona 49

4 Communication settings and guide of HMI connecting with controller RS485-2 communication cable HMI terminal9pin D-SUB female\maleController Modbus t

Strona 50

4 Communication settings and guide of HMI connecting with controller NOTE: If the servo controller to modify the station number, the servo power need

Strona 51 - Bosch Rexroth L25 Ethernet

4 Communication settings and guide of HMI connecting with controller ◎Cable Diagram ED Series RS232 communication cable HMI terminal9pin D-SUB female

Strona 52

4 Communication settings and guide of HMI connecting with controller 4.37 Kinco Master & Kinco Slave(Master/Slave Protocol Connection) ◎Serial

Strona 53

4 Communication settings and guide of HMI connecting with controller ◎Cable Diagram HMI terminal9pin D-SUB female/maleController terminal9pin D-SUB f

Strona 54

4 Communication settings and guide of HMI connecting with controller ◎Network System configuration Series CPU Link Module Connect Type Parameter

Strona 55

4 Communication settings and guide of HMI connecting with controller Keyence KV-N60AT protocol Default communication parameters, 9600bps, 8,even, 1

Strona 56

4 Communication settings and guide of HMI connecting with controller Keyence KV-5000 EtherNet Slave protocol HMI Setting PLC configuration 1. "E

Strona 57 - 4.13 CANOpen Node Slave

4 Communication settings and guide of HMI connecting with controller HMI terminal9pin D-SUB female/maleController com2 terminal9 pin D-SUB (male)2 TXD

Strona 58 - Parameters Setting

4 Communication settings and guide of HMI connecting with controller High speed counter ------ CTH_current0- 65534 DDDDD High speed counter ------ CTH

Strona 59

4 Communication settings and guide of HMI connecting with controller Example, PLC which corresponds to R009, the touch screen address is R0.09; PLC w

Strona 60

4 Communication settings and guide of HMI connecting with controller Internal auxiliary relay MR0-599.15 ------ DDD.DD Latch Relay LR0-199.15 --

Strona 61

4 Communication settings and guide of HMI connecting with controller Series CPU Link Module COMM Type Parameter Cable KOYO DIRECT SM24-T RS232 o

Strona 62

4 Communication settings and guide of HMI connecting with controller KOYO DL06 series RS422 communication setting ◎Cable Diagram KOYO SM24-T series

Strona 63

4 Communication settings and guide of HMI connecting with controller HMI terminal9pin D-SUB female/maleControllerRs485 terminal1 RX-6 RX+5 GNDBAFGcom0

Strona 64

4 Communication settings and guide of HMI connecting with controller 4.40 KTC Srdlink ◎Serial Communication Series CPU Link Module Driver SRD SRD2

Strona 65

4 Communication settings and guide of HMI connecting with controller NOTE: Must modify communication parameter in the programming software. ◎Suppor

Strona 66 - Danfoss

4 Communication settings and guide of HMI connecting with controller 4.41 KYL Slave ◎Serial Communication Series CPU Link Module Driver KYL Slave

Strona 67 - Modbus RTU Protocol:

4 Communication settings and guide of HMI connecting with controller Show valve state LB15 ------ DD Group close instruction LB17 ------ DD Stai

Strona 68

4 Communication settings and guide of HMI connecting with controller ◎Ethernet Communication (Direct Online Simulation disable) Series CPU Link Modu

Strona 69 - showed by RW register

4 Communication settings and guide of HMI connecting with controller Lecom AB RS485 communication ◎Supported Device Refer to the PLC software for de

Strona 70

4 Communication settings and guide of HMI connecting with controller Controller terminal9 pin D-SUB (male)com23 TX2 RX5 GND8 TX7 RX5 GNDcom0/com1HMI t

Strona 71

4 Communication settings and guide of HMI connecting with controller Cnet ON, DIP1 to be OFF /38400 LS Master-K MODBUS RTU Switch the DIP2 to be ON,

Strona 72 - DVP RS232 communication

4 Communication settings and guide of HMI connecting with controller RS485 communication PLC setting If click “Connect+Write+Run+Monitor Start”,

Strona 73 - DVP RS485-2 communication

4 Communication settings and guide of HMI connecting with controller LS Master-K CPU Direct protocol HMI Setting Default communication: 38400, 8, none

Strona 74

4 Communication settings and guide of HMI connecting with controller If click “Connect+Write+Run+Monitor Start”, it will give a “Cannot Change PLC Mo

Strona 75 - Delta DTA_DTB

4 Communication settings and guide of HMI connecting with controller RS485-2 communication PLC Setting 1. “Tools”---“Network Manager” set communicat

Strona 76 - Controller Setting

4 Communication settings and guide of HMI connecting with controller 2. Communicating in the OPR mode LS XGB CPU Direct HMI Setting Default communic

Strona 77

4 Communication settings and guide of HMI connecting with controller LS GLOFA Cnet protocol Default communication: 9600, 8, none, 1; station: 0 HMI Se

Strona 78

4 Communication settings and guide of HMI connecting with controller 2. Set the parameters of module Take G6L-CUEC for example, Open GMWIN, select

Strona 79

4 Communication settings and guide of HMI connecting with controller PLC-5/40 PLC-5/40L PLC-5/60 PLC-5/60L CompactLogix 1769-L20 1769-L30 1769-L31 176

Strona 80

4 Communication settings and guide of HMI connecting with controller The Slot No. is the I/O slot position where the communication module is. For exam

Strona 81 - RS485 terminal

4 Communication settings and guide of HMI connecting with controller HMI Setting PLC Setting 1. Modify the parameters of PLC: “Tools””Enet Frame Ed

Strona 82 - ENDA Controller Devices

4 Communication settings and guide of HMI connecting with controller 4. Download: “Online””Connect””Write” XGK-CPUE Setting HMI setting PLC setti

Strona 83

4 Communication settings and guide of HMI connecting with controller 2. Double click the [ base 00 ], in the pop-up window [communication module Set

Strona 84

4 Communication settings and guide of HMI connecting with controller ◎Supported Device LS Master-K CPU Direct Device Bit Address Word Address Form

Strona 85 - Emerson EC10

4 Communication settings and guide of HMI connecting with controller LS Master K-cnet Device Bit Address Word Address Format Notes I/O Relay P 0.0-25

Strona 86 - Emerson RS232 communication

4 Communication settings and guide of HMI connecting with controller Communication Register ------ N_ word 0-9999 DDDD Link Register ------ L_ word 0-

Strona 87 - 4.20 Epower

4 Communication settings and guide of HMI connecting with controller Auxiliary Register ------ M 0-9999 DDDD I/O Register ------ P 0-9999 DDDD

Strona 88 - 25 pin D-SUB (male)

4 Communication settings and guide of HMI connecting with controller Buffer Memory(Bit) MX0-131056 ------ DDDDD Output(Bit) QX0-1763 ------ DD

Strona 89

4 Communication settings and guide of HMI connecting with controller Read Holding Registers ------- 3X 1-65535 DDDDD Read Input Registers ------- 4X

Strona 90 - FACON FB RS232 communication

4 Communication settings and guide of HMI connecting with controller PLC Setting RSLogix500 software setting NOTE: Driver: DF1 Full Duplex; Err

Strona 91

4 Communication settings and guide of HMI connecting with controller 6 TX2 RX3 GNDController terminal6pin Mini DIN(male)HMI terminal9pin D-SUB female/

Strona 92

4 Communication settings and guide of HMI connecting with controller Controller terminal9pin D-SUB(male)4 RX7 TX5 GNDHMI terminal9pin D-SUB female/mal

Strona 93 - FB RS232 communication cable

4 Communication settings and guide of HMI connecting with controller ServoOne junior Lust ETH on the CPU Lust Ethernet Slave ◎Serial System configu

Strona 94 - 4.22 Fuji SPB

4 Communication settings and guide of HMI connecting with controller The way to change IP of Servo drive system Plug the 24-volt power supply on the

Strona 95

4 Communication settings and guide of HMI connecting with controller Parameter b3 b2 b1 b0 Initial IP int 192 168 39 5 hex C0 A8 27 05 Modified I

Strona 96 - GE Fanuc Series

4 Communication settings and guide of HMI connecting with controller D1 D2 l u Press key T2 of about 1s D1 D2 b 0 Press key T2 of about 1s D1 D2 b

Strona 97 - SNP RS485 on port2

4 Communication settings and guide of HMI connecting with controller CDE34.008 Refer to the Controller software for details: DriveManager for c-line d

Strona 98

4 Communication settings and guide of HMI connecting with controller HMI terminal 9pin D-SUB female/maleController terminal9 pin D-SUB (male)2 TXD3 RX

Strona 99

4 Communication settings and guide of HMI connecting with controller Device Bit Address Word Address Format LW.B 8000.0-8999.15 -------- DDDD.DD

Strona 100

4 Communication settings and guide of HMI connecting with controller RS485 PLC Setting 1.Open X_builder,New project,select PLC type(MC280) - 186 -

Strona 101

4 Communication settings and guide of HMI connecting with controller PLC Setting RSLogix5000 software setting NOTE: Protocol: DF1 Point to Point; Err

Strona 102

4 Communication settings and guide of HMI connecting with controller 2.Open System block→Comm Port,set comm port(support Modbus) (1)Port0 setting(RS

Strona 103 - ◎Cable Diagram

4 Communication settings and guide of HMI connecting with controller Notes:Using X_builder,Main routine cannot be empty ◎ Supported Device Device Bi

Strona 104 - CMM311 RS422 communication

4 Communication settings and guide of HMI connecting with controller HMI接线端9pin D-SUB female/maleController port0接线端8 pin Mini Din (male)5 TXD4 RXD3

Strona 105 - Haiwell RS232 communication

4 Communication settings and guide of HMI connecting with controller PLC Setting ◎Supported Device Device Bit Address Word Address Format Input

Strona 106 - Haiwell RS485 communication

4 Communication settings and guide of HMI connecting with controller ◎Cable Diagram RS232 Communication HMI terminal9pin D-SUB female\maleController

Strona 107 - ◎Communication Setting

4 Communication settings and guide of HMI connecting with controller RS485-2 Communication: ◎Supported Device Device Bit Address Word Address For

Strona 108 - Hitachi SJ300

4 Communication settings and guide of HMI connecting with controller Users need to make the communication cable for M3 and HMI (region of red marquee

Strona 109 - Inverter internal setting

4 Communication settings and guide of HMI connecting with controller FX1NC FX2N FX2NC FX□□-422-BD*3 FX□□-485-BD*3 FX□□-485-ADP*3 Mitsubishi FX0N/1N/2N

Strona 110 - Hitachi

4 Communication settings and guide of HMI connecting with controller NOTE: 1. *1 The protocol support multi-station 2. *2 The protocol don’t support m

Strona 111 - ◎Serial System configuration

4 Communication settings and guide of HMI connecting with controller FX2NC FX□□-485-ADP FX□□-232-BD RS232 Setting Your owner cable FX2N-10GM FX2N-20G

Strona 112 - Port 2 on CPU

To be the partner of your success 4.32 Invt ...

Strona 113

4 Communication settings and guide of HMI connecting with controller NOTE: Define the new device in the RSLogix5000 before using the register in the

Strona 114 - - 111

4 Communication settings and guide of HMI connecting with controller Q01CPU Q02CPU Q02HCPU Q06HCPU Q12HCPU Q25HCPU Q03UDECPU Q04UDEHCPU Q06UDEHCPU Q13

Strona 115 - - 112

4 Communication settings and guide of HMI connecting with controller HMI Setting When using the Mitsubishi FX1S、Mitsubishi FX0N/1N/2N/3G、Mitsubishi

Strona 116

4 Communication settings and guide of HMI connecting with controller PLC Setting Select the “Operate communication setting” NOTE: 1. FX0N series d

Strona 117 - ◎Serial System Configuration

4 Communication settings and guide of HMI connecting with controller D8120 Communication format D8121 Station number D8129 Overtime For example The

Strona 118 - RS485-2

4 Communication settings and guide of HMI connecting with controller Mitsubishi Q00J (CPU Port) protocol HMI Setting Default parameters: 19200, 8, od

Strona 119

4 Communication settings and guide of HMI connecting with controller HMI Setting Default parameters :115200, 8, odd, 1 ; Station No. : 0(Non-support s

Strona 120 - RS232 communication

4 Communication settings and guide of HMI connecting with controller The differences of Mitsubishi Q_QnA (Link Port)、Mitsubishi Melsec Q: 1. Mitsubis

Strona 121 - RS232 Port

4 Communication settings and guide of HMI connecting with controller b. Click “type” to select “intelligent” c. Click “switch setting” and set - 20

Strona 122 - RS485 Port

4 Communication settings and guide of HMI connecting with controller Setting the intelligent function unit switch switch content example Switch1 CH

Strona 123

4 Communication settings and guide of HMI connecting with controller If the communcation parameters of CH1 232 is 19200/8/odd/1, station:0, set as

Strona 124 - Inovance H2u protocol

4 Communication settings and guide of HMI connecting with controller Example: Build a new tag whose name is a, the Data Type is INT: Note: 1. For the

Strona 125 - PLC Setting

4 Communication settings and guide of HMI connecting with controller NOTE:Data fomat of PORT number is decimalism PLC Setting FX3GE-24M 1. D

Strona 126 - PLC setting

4 Communication settings and guide of HMI connecting with controller NOTE: Data fomat of PORT number is decimalism FX3U-ENET-L 1. Open“FX3U-ENET-

Strona 127

4 Communication settings and guide of HMI connecting with controller 3. Click“Open settings”,the parameters configuration as follow: NOTE: Data fom

Strona 128

4 Communication settings and guide of HMI connecting with controller PLC Setting 1. Network parameters [network type] select "Ethernet";

Strona 129

4 Communication settings and guide of HMI connecting with controller "1"; [Group number] range is 0-32, select "0"; [station numbe

Strona 130

4 Communication settings and guide of HMI connecting with controller Mitsubishi QnA 3EBin Ethernet(TCP Slave) protocol L02: HMI Setting NOTE: 1.

Strona 131 - RS232 communication cable

4 Communication settings and guide of HMI connecting with controller Click “Open Setting”, the parameters configuration as follow: NOTE: Host Stati

Strona 132 - RS485 communication cable

4 Communication settings and guide of HMI connecting with controller NOTE: 1. PLC station number must be 255 2. Data format of Port number is decim

Strona 133 - Kinco PLC Series

4 Communication settings and guide of HMI connecting with controller NOTE: Host Station Port No. will be set by the selected format. ◎Supported Devic

Strona 134

4 Communication settings and guide of HMI connecting with controller State S 000-999 ------ DDD Timer Value ------ T_word 000-255 DDD Counter Val

Strona 135

4 Communication settings and guide of HMI connecting with controller Note: 1. The File Number is unique, a same File Number cannot map to different Na

Strona 136

4 Communication settings and guide of HMI connecting with controller Counter Value ------ C_dword200-255 DDD 32 bit device Q00jCPU Device Bit Addre

Strona 137

4 Communication settings and guide of HMI connecting with controller Timer Contact TS 0-511 ------ DDDD Link Relay B 0-7FF HHHH Edge Relay V 0-1023

Strona 138

4 Communication settings and guide of HMI connecting with controller Q_QnA(link port) Device Bit Address Word Address Format Special Link Relay SB00

Strona 139 - Project configuration

4 Communication settings and guide of HMI connecting with controller Special Data Register ------ SD 0000-2047 DDDD Mitsubishi QJ71E71 EtherNet Slave

Strona 140 - - 137

4 Communication settings and guide of HMI connecting with controller Step Coil SC 0-2047 ------ DDDD Step Contact SS 0-2047 ------ DDDD Timer Coil T

Strona 141 - RS485-4 communication cable

4 Communication settings and guide of HMI connecting with controller Latch Relay L 0-8191 ------ DDDD Special Internal Relay SM 0-2047 ------ DDDD I

Strona 142 - Kinco Servo Series

4 Communication settings and guide of HMI connecting with controller com0/com1HMI terminal9pin D-SUB female/male1 RX-6 RX+5 GND4Tx-7Tx+3GND1Rx-2Rx+4 T

Strona 143

4 Communication settings and guide of HMI connecting with controller com0/com1HMI terminal9pin D-SUB female/male2 RX3 TX2 TXD1 RXD5 GND3 GNDController

Strona 144

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Relay CB 00-

Strona 145 - Kinco Slave

4 Communication settings and guide of HMI connecting with controller 4.51 Modbus ◎Serial Communication Series CPU Link Module SIO type Driver Modb

Strona 146 - Keyence KV-3000

4 Communication settings and guide of HMI connecting with controller AB CompactLogix/ControlLogix Series Ethernet(TCP Slave) protocol HMI Setting P

Strona 147 - - 144

4 Communication settings and guide of HMI connecting with controller NOTE: 1. Modbus RTU protocol supports broadcasting station number, but the rad

Strona 148 - - 145

4 Communication settings and guide of HMI connecting with controller Modbus RTU MT500 compatible protocol RS232 communication Default communicatio

Strona 149 - KV-16DT

4 Communication settings and guide of HMI connecting with controller Modbus TCP protocol Network configuration Modbus UDP protocol Network config

Strona 150 - KV-3000

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Modbus RTU Device Bit Address Word Address Format Notes Ou

Strona 151 - KV-N60AT

4 Communication settings and guide of HMI connecting with controller 12 3 4 5 6 7 84X-DINV(2word)H4X(2word)5 6781 234 H5X(2word)7 8 5 63 412 HH Lbyte

Strona 152 - Koyo Direct

4 Communication settings and guide of HMI connecting with controller Data relay 4X_bit 1.00-65535.15 ------ DDDDD.DD Input Register ------ 3X

Strona 153 - PLC software setting

4 Communication settings and guide of HMI connecting with controller System configuration Series CPU Link Module COMM Type Parameter Cable MODROL

Strona 154

4 Communication settings and guide of HMI connecting with controller 4.53 OE MAX ◎Serial Communication Series CPU Link Module Driver NX7 NX7 RS23

Strona 155 - 9pin D-SUB female/male

4 Communication settings and guide of HMI connecting with controller General Register ------ W_word 0-2047 DDDD Special Register ------ SR_word 0-511

Strona 156 - KTC RS485-2 communication

4 Communication settings and guide of HMI connecting with controller C2000H C1000HF C500-LK201-V1 C500-LK203 C20H/28H/40H Link I/F on the CPU unit C2

Strona 157

4 Communication settings and guide of HMI connecting with controller Output data file O0:0.0-255.15 ------ DD.DD Input data file I1:0.0-255.15 ----

Strona 158 - 4.41 KYL Slave

4 Communication settings and guide of HMI connecting with controller CJ1G-CPU44H CJ1G-CPU43H CJ1G-CPU42H CJ1M-CPU23 CJ1M-CPU22 CJ1M-CPU21 CJ1M-CPU13 C

Strona 159 - Lecom AB RS232 communication

4 Communication settings and guide of HMI connecting with controller CS1H CS1G CS1W-ETN21/EIP21 (UDP Slave) CJ1W-ETN21/EIP21 CJ2H-***-EIP SYSMAC NJ N

Strona 160 - Lecom AB RS485 communication

4 Communication settings and guide of HMI connecting with controller CS1G-CPU45H CS1G-CPU44H CS1G-CPU43H CS1G-CPU42H CS1G-CPU45-V1 CS1G-CPU44-V1 CS1G-

Strona 161

4 Communication settings and guide of HMI connecting with controller ◎Serial Communication Setting OMRON CP Series Host Link protocol HMI Setting Defa

Strona 162 - LS Master-K Cnet protocol

4 Communication settings and guide of HMI connecting with controller 5 ON: communication port2,Toolbus(default) OFF:Port 2 communications settings acc

Strona 163 - RS485 communication

4 Communication settings and guide of HMI connecting with controller NOTE: Select custom communication parameters (non-standard communication paramet

Strona 164 - - 161

4 Communication settings and guide of HMI connecting with controller ◎Network Communication Setting OMRON CJ Series Ethernet(TCP Slave) HMI Setting

Strona 165 - - 162

4 Communication settings and guide of HMI connecting with controller 2. Double-click the Ethernet communication module, set the parameters OMRON CJ

Strona 166 - RS485-2 communication

4 Communication settings and guide of HMI connecting with controller Attention: HMI and PLC must be set in the same network,while the node ID should

Strona 167 - LS XGB CPU Direct

4 Communication settings and guide of HMI connecting with controller 5. Set the Network number and Node ID (1)Network number (2)You can change the

Strona 168 - - 165

4 Communication settings and guide of HMI connecting with controller Note: *1 Variable less than three address the need to fill the former 0 The cor

Strona 169 - - 166

4 Communication settings and guide of HMI connecting with controller PLC Setting Type in IE the IP address(ex:http://192.168.11.33/C00.HTM)and the p

Strona 170 - - 167

4 Communication settings and guide of HMI connecting with controller Omron C Series Host Link Device Bit Address Word Address Format Hold Relay HR_bi

Strona 171

4 Communication settings and guide of HMI connecting with controller Device Bit Address Word Address Format Channel I/O CIO 0000.00-6143.15 -----

Strona 172 - XGK-CPUE Setting

4 Communication settings and guide of HMI connecting with controller 0.00-6143.15 CIO_FORCE ------ CIO_FORCE_RELEASE ------ CIO_RELEASE_STATUS -

Strona 173 - - 170

4 Communication settings and guide of HMI connecting with controller Channel IO 0.00-6143.15 CIO_bit ------ DDDD.DD CIO_FORCE ------ CIO_FORCE_RELE

Strona 174

4 Communication settings and guide of HMI connecting with controller Controller terminal9pin D-SUB(male)3 RD2 SD9 GND4 RTS5 CTSHMI terminal9pin D-SUB

Strona 175 - - 172

4 Communication settings and guide of HMI connecting with controller HMI terminal9pin D-SUB female/male1 RX-6 RX+5 GNDSDA-SDB+FGRDA-RDB+4 TX-9 TX+Cont

Strona 176 - - 173

4 Communication settings and guide of HMI connecting with controller ◎Communication Setting Default communication: 9600, 7, even, 2; station: 0 ◎Supp

Strona 177 - - 174

4 Communication settings and guide of HMI connecting with controller 3 AT execute/stop 00:stop 01:AT execute 4 write-in mode 00:save 01:RAM 5 RAM

Strona 178 - LS iG5A protocol

4 Communication settings and guide of HMI connecting with controller Series CPU Link Module Connect Type Parameter Cable OPTO 22 SNAP-UP1-ADS E

Strona 179

4 Communication settings and guide of HMI connecting with controller Integer data file ------ INT000000~254255 DDDDDD*1 DInteger data file ------ DI

Strona 180 - 5 GND 3 GND

4 Communication settings and guide of HMI connecting with controller Tune I Float Tune D Float Mode Double IN BIT QN BIT PIN Float PQN Float NT

Strona 181 - RS422 communication cable

4 Communication settings and guide of HMI connecting with controller 4.57 Panasonic Electric Corporation ◎Serial Communication Series CPU Link Modul

Strona 182

4 Communication settings and guide of HMI connecting with controller FP2SH RS232C port on the Control unit Your owner cable AFP2462 AFP2465 AFP2803 A

Strona 183 - - 180

4 Communication settings and guide of HMI connecting with controller RS422 communication ◎Supported Device FP Series Device Bit Address Word Addre

Strona 184 - - 181

4 Communication settings and guide of HMI connecting with controller Link Relay WL0~32767 DDDDD File Register FL0~99999 DDDDD NOTE: 1. Exa

Strona 185

4 Communication settings and guide of HMI connecting with controller HMI terminal9pin D-SUB female/malecom23 TX2 RX5 GND8 TX7 RX5 GNDcom0/com1Controll

Strona 186 - ServoOne junior

4 Communication settings and guide of HMI connecting with controller Parker Compax3 Compax3 RS232 on CPU unit Parker Compax3 RS485 on CPU unit Parker

Strona 187 - 4.45 Memory map

4 Communication settings and guide of HMI connecting with controller PLC Setting NOTE: RS-485 Settings can be made in the C3 Servo Manager under “RS4

Strona 188

4 Communication settings and guide of HMI connecting with controller Parker 6K protocol Default communication parameters: 9600, 8, 1, none; station:

Strona 189

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Parker Compax3 Device Bit Address Word Address Format R_Bit 0

Strona 190 - - 187

4 Communication settings and guide of HMI connecting with controller com23 TX2 RX5 GND8 TX7 RX5 GNDcom0/com1HMI terminal9pin D-SUB female/male2 TXD3 R

Strona 191 - ◎ Cables Production

4 Communication settings and guide of HMI connecting with controller TAS_Bit 1.01-2.32 ------ TSS_Bit 1-32 ------ TIN_Bit 1.01-3.32 -

Strona 192

4 Communication settings and guide of HMI connecting with controller com0/com1HMI terminal9pin D-SUB female/maleControllerRS485 terminal1 RX-6 RX+3 T

Strona 193

4 Communication settings and guide of HMI connecting with controller 4.59 PMAC Motion Controller ◎Serial Communication Series CPU Link Module Driv

Strona 194

4 Communication settings and guide of HMI connecting with controller Run current program ------ RUN 0-9999 DDDD W Halt program ------ HLT 0-9999 DDDD

Strona 195

4 Communication settings and guide of HMI connecting with controller AURORA PVI-6000-OUTD-US-W RS485 on the port Aurora PV ◎System configuration Se

Strona 196

4 Communication settings and guide of HMI connecting with controller com0/com1HMI terminal9pin D-SUB female/maleControllerRS485 terminal1 Rx-(A)6 Rx+(

Strona 197 - - 194

4 Communication settings and guide of HMI connecting with controller NOTE:Input and Output Modules should match with Master Configuration. PLC Sett

Strona 198 - NOTE: 1. *

4 Communication settings and guide of HMI connecting with controller (4) Right click,choose “Insert Object” C

Strona 199 - - 196

4 Communication settings and guide of HMI connecting with controller (6) Profibus DP Slave has adaption function,you can change the transmission rate

Strona 200

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Direct I/O

Strona 201

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Linear Decele

Strona 202

4 Communication settings and guide of HMI connecting with controller Series CPU Link Module Driver RF-IC RF-IC RS232 on the CPU unit RF-IC ◎Syst

Strona 203 - RS422 communication

4 Communication settings and guide of HMI connecting with controller ◎System configuration Series CPU Link Module COMM Type Parameter Cable RKC C

Strona 204 - - 201

4 Communication settings and guide of HMI connecting with controller 4 7 even 1 5

Strona 205 - - 202

4 Communication settings and guide of HMI connecting with controller HMI CAN terminal9pin D-SUB female2 CAN_L7 CAN_H2 CAN_L7 CAN_HController CAN term

Strona 206

4 Communication settings and guide of HMI connecting with controller RS485 communication ◎Supported Device Device Bit Address Word Address Format Not

Strona 207 - - 204

4 Communication settings and guide of HMI connecting with controller com0/com1ControllerRS485 terminalHMI terminal9pin D-SUB female/male1 RX-X1-1X1-26

Strona 208 - - 205

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Channel Sampl

Strona 209

4 Communication settings and guide of HMI connecting with controller TSX 37 10 028DR1 TSX 37 21 101 TSX 37 22 101 TSX 37 21 001 TSX 37 22 001 Premium

Strona 210 - FX3GE-24M

4 Communication settings and guide of HMI connecting with controller TSX3705001 TSX3705001 TSX 37 05 028DR1 TSX 37 08 056DR1 TSX 37 10 128DT1 TSX 37 1

Strona 211 - FX3U-ENET-L

4 Communication settings and guide of HMI connecting with controller Modbus RTU protocol Default communication:9600, 8, even, 1; station: 1 RS232

Strona 212

4 Communication settings and guide of HMI connecting with controller HMI terminal9pin D-SUB female/maleController terminal9 pin D-SUB (male)3 TXD2 RXD

Strona 213

4 Communication settings and guide of HMI connecting with controller PLC Setting PL7 software setting 1. Start menu“modicum telemecanique”  “XWAY D

Strona 214 - - 211

4 Communication settings and guide of HMI connecting with controller 4. And then click ”XWAY Test””Connect”, if the connection is successful,

Strona 215

4 Communication settings and guide of HMI connecting with controller Modbus RTU protocol setting as follow: 6. Setting up the configuration and do

Strona 216

4 Communication settings and guide of HMI connecting with controller RS485 communication PLC Setting 1. Specify a large number for the internal word

Strona 217

4 Communication settings and guide of HMI connecting with controller 2. You must program a coil with maximum address to open the memory area for th

Strona 218

4 Communication settings and guide of HMI connecting with controller PLC software setting: “Hardware Configuration”double click “Ccom” to select “MOD

Strona 219 - - 216

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format State instructions(W

Strona 220 - - 217

4 Communication settings and guide of HMI connecting with controller 14H SC_L Read PV lower limit side scaling 15H SC_H Read PV higher limit sid

Strona 221 - - 218

4 Communication settings and guide of HMI connecting with controller 4.68 SIEMENS ◎Serial Communication Series CPU Link Module Driver S7-200 CPU2

Strona 222 - - 219

4 Communication settings and guide of HMI connecting with controller CPU314IFM CPU315 CPU315-2 DP CPU316 CPU316-2 DP CPU318-2 NOTE 1. *1 :The proto

Strona 223 - - 220

To be the partner of your success 4.76 Trio motion controller ...

Strona 224 - - 221

4 Communication settings and guide of HMI connecting with controller Note: PLC station must match with the ADAM-4015 configuration. PLC Setting Conne

Strona 225 - FX Series RS422 Cable

4 Communication settings and guide of HMI connecting with controller ◎BUS Communication Please refer to 4.59 Profibus DP Slave. ◎Serial System configu

Strona 226 - Q02U Series RS232 Cable

4 Communication settings and guide of HMI connecting with controller SIMATIC S7-200 CPU222 CPU224 CPU224 XP CPU226 CP 243-1 IT CP 243-1 Ethernet Setti

Strona 227 - Q Series RS485/422 Cable

4 Communication settings and guide of HMI connecting with controller PLC Setting SIEMENS S7-300/400 (PC Adapter Direct) protocol HMI Setting Defaul

Strona 228

4 Communication settings and guide of HMI connecting with controller NOTE: 1. If you use MT5-S7-300 adapter to communicate, the baudrate of PLC must

Strona 229

4 Communication settings and guide of HMI connecting with controller 3. After the software change, downloaded to PLC, make sure the transmission rate

Strona 230 - - 227

4 Communication settings and guide of HMI connecting with controller SIEMENS S7-300/400 (MPI Direct) protocol HMI Setting NOTE: 1. This protocol i

Strona 231 - - 228

4 Communication settings and guide of HMI connecting with controller 2. This protocol supports multi-station communication, and the MPI is RS485 port,

Strona 232 - - 229

4 Communication settings and guide of HMI connecting with controller PLC setting PLC station No. can be 2-15, MPI baud rate can be 19.2k or 187.5k

Strona 233 - Modbus RTU Extend

4 Communication settings and guide of HMI connecting with controller PLC Setting The settings for the CP 243-1 are defined in STEP 7 Micro/WIN via th

Strona 234 - - 231

4 Communication settings and guide of HMI connecting with controller 3. Specifying IP address 3.0 Define an IP address for the CP 243-1. Caution:The

Strona 235 - Ethernet communication cable

4 Communication settings and guide of HMI connecting with controller Read Version ——— Version 0-65535 DDDDD Read Module Name ——— Name 0-65535 DDDDD No

Strona 236 - MODROL RS485

4 Communication settings and guide of HMI connecting with controller 5. Configuration connection 7.0 The configuration for connecting the CP 243-1

Strona 237 - 4.53 OE MAX

4 Communication settings and guide of HMI connecting with controller 7. Assigning memory 11.0 Specify a memory area for the configuration of the CP

Strona 238 - 4.54 Omron Corporation

4 Communication settings and guide of HMI connecting with controller 9. Confirm message 13.0 Click “Yes” to confirm the message that appears. 10.

Strona 239 - - 236

4 Communication settings and guide of HMI connecting with controller SIEMENS S7-1200 Ethernet(TCP Slave) protocol HMI Setting PLC Setting 1. Modif

Strona 240 - ◎Network Communication

4 Communication settings and guide of HMI connecting with controller c. Select the device, press “Load”. 2. Build the data block Data block must be c

Strona 241

4 Communication settings and guide of HMI connecting with controller NOTE: 1. Make sure the data type of PLC same as the HMI when defining the data b

Strona 242 - CS1W-SCB41

4 Communication settings and guide of HMI connecting with controller 1. In “HW configuration” insert CP300 industrial Ethernet. 2. Set IP address in

Strona 243

4 Communication settings and guide of HMI connecting with controller NOTE: Dual redundant parameters configuration of S7-400 Ethernet communication

Strona 244 - - 241

4 Communication settings and guide of HMI connecting with controller PLC Setting 1. In the hardware configuration, insert CP400 Ethernet module CP443-

Strona 245 - - 242

4 Communication settings and guide of HMI connecting with controller V Relay V.B 0.0-10238.7 ------ DDDDD.O Internal Memory Relay M.B 0.0-31.7 -----

Strona 246

4 Communication settings and guide of HMI connecting with controller ◎Communication Setting ◎Supported Device Device Bit Address Word Address Form

Strona 247

4 Communication settings and guide of HMI connecting with controller SIEMENS S7-300/400 (PC Adapter Direct) Device Bit Address Word Address Format

Strona 248

4 Communication settings and guide of HMI connecting with controller bit) Data Register Relay ------ DBn_DBW 100000-409665534 DDDDDDDDD n:1~4096 Dat

Strona 249

4 Communication settings and guide of HMI connecting with controller 2. DBn_DBX, DBn_DBW, DBn_DBD is a custom block. First three data formats for data

Strona 250

4 Communication settings and guide of HMI connecting with controller External Input node I 0.0~255.7 ------ DDD.O External Output node Q 0.0~255.7

Strona 251 - - 248

4 Communication settings and guide of HMI connecting with controller PC/PPI Cable switch to select the baud rate Baud SWITCH(1=on) 38400 000 19200 0

Strona 252 - - 249

4 Communication settings and guide of HMI connecting with controller PC / PPI cable on the baud rate DIP switch settings, you must set the baud rate w

Strona 253 - - 250

4 Communication settings and guide of HMI connecting with controller Ethernet communication protocol cable Cross-connection or crossover network cabl

Strona 254 - RS232 Communication Cable

4 Communication settings and guide of HMI connecting with controller PLC Setting Please reference to controller manual. ◎Supported Device Device Bit

Strona 255 - RS422 Communication Cable

4 Communication settings and guide of HMI connecting with controller RS485 ◎ Supported Device Device Bit Address Word Address Format Notes Inp

Strona 256

4 Communication settings and guide of HMI connecting with controller State S 000-999 ------ DDD Timer Value ------ T_word 000-255 DDD Counter Val

Strona 257 - OMRON E5EZ-R3

4 Communication settings and guide of HMI connecting with controller BACnet IP Ethernet interface on CPU BACnet IP ◎Serial System configuration Se

Strona 258 - OPTO 22 SNAP Ethernet(TCP)

4 Communication settings and guide of HMI connecting with controller Default communication: 19200, 8, none, 1; station: 1 RS232 communication RS485 c

Strona 259 - Register

4 Communication settings and guide of HMI connecting with controller Counter(Current value) ------ C_Current_Word 0-199 DDD Counter ------ C_Curre

Strona 260

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Please refer to TMCL Reference Manual for device details TMCM_

Strona 261 - Panasonic FP

4 Communication settings and guide of HMI connecting with controller GIO 0.0-0.10 2.0-2.07 1.0-1.7 DDD.DD Read Only CALC ------ 0-9 D Write Only

Strona 262

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Internal Rela

Strona 263

4 Communication settings and guide of HMI connecting with controller S0~S1023 0X 20481~0X 21504 M8000~M8511 0X 24577~0X 25088 T0~T618 0X 25601~0X 2

Strona 264 - Tool port:

4 Communication settings and guide of HMI connecting with controller D3CellTM D3CellTM RS485 on the CPU unit RS422 Setting Your owner cable ◎Su

Strona 265

4 Communication settings and guide of HMI connecting with controller ◎Network Communication Setting HMI setting TCXMAIN1: S2PU72A: PLC setting -

Strona 266 - Parker Compax3 protocol

4 Communication settings and guide of HMI connecting with controller Please refer to the communication equipment related documentation to set the para

Strona 267 - Parker SLVD Series protocol

4 Communication settings and guide of HMI connecting with controller 0x6C000000-0x6C003FFF R6C_B 0.00-3FFF.1F ------ HHHH.HH 0x6D000000-0x6D003FFF

Strona 268 - Parker ACR9000 protocol

4 Communication settings and guide of HMI connecting with controller PLC Setting Please refer to the communication equipment related documentation t

Strona 269

4 Communication settings and guide of HMI connecting with controller 0x6A000000-0x6A003FFF ------ R6A 0-3FFF HHHH 0x6B000000-0x6B003FFF ------ R6B

Strona 270 - Parker Compax3 Series

4 Communication settings and guide of HMI connecting with controller Controller internal setting: RS485-4 communication Controller internal settin

Strona 271 - 6k/9000 Series

4 Communication settings and guide of HMI connecting with controller Trio controller setting: SETCOM(baudrate, databits, stopbits, parity, port, 5) SE

Strona 272

4 Communication settings and guide of HMI connecting with controller ADDRESS=1 SETCOM(9600,8,1,2,1,4) ◎Supported Device TRIO Device Bit Address Word

Strona 273

4 Communication settings and guide of HMI connecting with controller HMI terminal9pin D-SUB female/maleController B port terminal 8 pin Mini Din (male

Strona 274

4 Communication settings and guide of HMI connecting with controller RS485 default communication: 57600, 8, 1, none; station: 64 PLC Setting 1. COM

Strona 275

4 Communication settings and guide of HMI connecting with controller 2. Initialize ID, and program as below, download to controller. 3. Change the j

Strona 276

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Inputs I 0~99

Strona 277 - - 274

4 Communication settings and guide of HMI connecting with controller Ethernet communication protocol cable Cross-connection or crossover network cab

Strona 278 - - 275

4 Communication settings and guide of HMI connecting with controller Device Bit Address Word Address Format Notes send LB 0 ------ D

Strona 279 - A-type violet cable

4 Communication settings and guide of HMI connecting with controller PLC Setting Please refer to the communication equipment related documentation to

Strona 280

4 Communication settings and guide of HMI connecting with controller NOTE:CP1* baudrate 19200bps. *:CP1 programming port is USB(RS232). ◎Supported De

Strona 281

4 Communication settings and guide of HMI connecting with controller 3 RXD2 TXD1 GNDPLC Auxiliary interfaceJST 4PIN JST 4PIN com23 TX2 RX5 GND8 TX7 RX

Strona 282

4 Communication settings and guide of HMI connecting with controller C FJOG ------ C 0 D D RJOG ------ D 0 D E Free halt ------ E0 D F

Strona 283 - ◎Systems Configuration

4 Communication settings and guide of HMI connecting with controller ◎Communication Setting HMI Setting Yamatake DCP30 protocol Default communication:

Strona 284 - PCS1.C8

4 Communication settings and guide of HMI connecting with controller PLC Setting 1. Set modbus RTU in the SLP-D10, and then download. 2. Station mat

Strona 285

4 Communication settings and guide of HMI connecting with controller FBR2_R ------ 1.0-30.22 DDD.DD FBR3_R ------ 1.0-30.22 DDD.DD FBR4_R ---

Strona 286

4 Communication settings and guide of HMI connecting with controller Sub addr DD correspond to temperature controller: Sub Addr Parameter Sub Addr Par

Strona 287

4 Communication settings and guide of HMI connecting with controller Commutator terminal9 pin D-SUB male2 TX3 RX5 GNDcom23 TX2 RX5 GND8 TX7 RX5 GNDcom

Strona 288

4 Communication settings and guide of HMI connecting with controller ∑Ⅱ /∑Ⅱ P lu s(Servo Controller) SGDM RS232 on the CPU unit Yaskawa SGDM RS422 on

Strona 289

4 Communication settings and guide of HMI connecting with controller H5-01 Secondary station address 0~FFH Secondary station number 1F H5-02 The ch

Strona 290

4 Communication settings and guide of HMI connecting with controller Analog Input ------ AI 0-65535 DDDDD Float Analog Output ------ AO 0-65535 DDDDD

Strona 291 - - 288

4 Communication settings and guide of HMI connecting with controller RS485-4 communication PLC Setting Related parameters Settings refer to the

Strona 292

4 Communication settings and guide of HMI connecting with controller NOTE: Station No. is a decimal number corresponding to axis address of servo co

Strona 293

4 Communication settings and guide of HMI connecting with controller NOTE: 1. axis address 0020H is the station number of PLC,here is hexadecimal,HMI

Strona 294

4 Communication settings and guide of HMI connecting with controller PLC Setting 1. Set the IP,connect with the MPE720 software 2. How to set the IP

Strona 295 - 4.67 SHIMADEN FP23

4 Communication settings and guide of HMI connecting with controller Change, save, and save to flash: Restart the controller and the set is ok. If

Strona 296

4 Communication settings and guide of HMI connecting with controller ◎Supported Device V inverter Device Bit Address Word Address Format Notes Intern

Strona 297

4 Communication settings and guide of HMI connecting with controller SGDV Device Bit Address Word Address Format Function Selection ------------ (Pn00

Strona 298 - SIEMENS S7-200

4 Communication settings and guide of HMI connecting with controller HMI terminal9pin D-SUB female/maleController terminal1 RX-6 RX+R-S+R+com0/com1S-

Strona 299 - - 296

4 Communication settings and guide of HMI connecting with controller Ethernet communication protocol cable Cross-connection or crossover network cable

Strona 300 - ◎BUS Communication

4 Communication settings and guide of HMI connecting with controller F3LC11-2N ◎Network Communication(direct online simulation disable) Series

Strona 301 - SIEMENS S7-200 protocol

4 Communication settings and guide of HMI connecting with controller ControllerRS485 terminalHMI terminal9pin D-SUB female/male- +com0/com11 RX-6 RX+

Strona 302

4 Communication settings and guide of HMI connecting with controller F3SP20-0N F3SP21-0N F3SP25-2N F3SP28-3N F3SP30-0N F3SP35-5N F3SP38-6N F3SP53-4H

Strona 303

4 Communication settings and guide of HMI connecting with controller RS485-4 default communication: 19200, 8, 1, none; station: 1 RS485-2 default c

Strona 304 - - 301

4 Communication settings and guide of HMI connecting with controller PLC Setting RS485-4 communication configuration Set the 485 communication modul

Strona 305

4 Communication settings and guide of HMI connecting with controller 8 OFF Always OFF 3. Station No. setting 1 4. Set the termination resistance swi

Strona 306 - HMI setting

4 Communication settings and guide of HMI connecting with controller Index Register ------ V_word 1~64 DD File Register ------ B_word 1~256 DD

Strona 307 - - 304

4 Communication settings and guide of HMI connecting with controller AI AI-518 AI-701 RS485 on the CPU unit YuDian AI Single_Loop AI-7048 RS485 on t

Strona 308

4 Communication settings and guide of HMI connecting with controller NOTE: 1、When setting the parameter of ADDR, it match the PLC Station Number . 2、I

Strona 309 - - 306

4 Communication settings and guide of HMI connecting with controller 1 HIAL HIAL HIAL HIAL 2 LoAL LoAL LoAL LoAL 3 dH

Strona 310 - - 307

4 Communication settings and guide of HMI connecting with controller 40 C08 C08 41 t08 t08 42 C09 C09 43-85 t09-C30 t09-C3

Strona 311 - - 308

4 Communication settings and guide of HMI connecting with controller 30 1EH PHIA 31 1FH PLoA 32 20H ALP 33 21H FSb 34 22H

Strona 312

4 Communication settings and guide of HMI connecting with controller ◎Supported Device - 35 -

Strona 313

4 Communication settings and guide of HMI connecting with controller ◎Network System configuration Series CPU Link Module COMM Type Parameter Cab

Strona 314 - - 311

4 Communication settings and guide of HMI connecting with controller (3)Update and get configuration: After finish the system basic configuration

Strona 315

4 Communication settings and guide of HMI connecting with controller (4)Click icon after updating controller configuration, then it will pop upWinE

Strona 316

4 Communication settings and guide of HMI connecting with controller (Only data of comms can be monitored, some address greater than or equal to 100 a

Strona 317 - - 314

1 Serial Communication Pin definition MT5000/4000 Series HMI and PLC connecting guide 1 Serial Communication Pin definition  Serial port COM0 COM0 i

Strona 318

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Word -------

Strona 319 - - 316

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes Bit type DB_B

Strona 320 - NOTE:

4 Communication settings and guide of HMI connecting with controller ◎Communication Setting ◎Supported Device Device Bit Address Word Address Form

Strona 321 - - 318

4 Communication settings and guide of HMI connecting with controller 4.11 Bosch Rexroth ◎Serial Communication Series CPU Link Module Driver PPC-R

Strona 322 - - 319

4 Communication settings and guide of HMI connecting with controller NOTE: To communicate with the touch screen, declare variable firstly in the Rexr

Strona 323

4 Communication settings and guide of HMI connecting with controller PLC Setting PPC-R software setting PLC connects with PC via crossover ethernet

Strona 324 - - 321

4 Communication settings and guide of HMI connecting with controller 3. “Resource”--->“Global variables”--->declare variable in “HMI” 4. Click

Strona 325 - SIEMENS MPI protocol

4 Communication settings and guide of HMI connecting with controller NOTE:Must select Download symbol file Click “OK” and pop-up the window as follo

Strona 326 - 4.69 SIKO AG05 SIKONETZ5

4 Communication settings and guide of HMI connecting with controller Input B0 and pop-up the dialog, configurations as follows, click “OK”: And set u

Strona 327

4 Communication settings and guide of HMI connecting with controller Setting communication parameter: Then click “Login”: Communicating successfull

Strona 328 - RS485

1 Serial Communication Pin definition 4 NC -- 5 SG Signal ground 6 NC -- 7 RXD Receive data 8 TXD Transmit data 9 NC -- The COM2 can be

Strona 329 - 4.71 TAIAN

4 Communication settings and guide of HMI connecting with controller NOTE:The PLC panel must be set up, press” Enter”, then press” △”, un

Strona 330

4 Communication settings and guide of HMI connecting with controller com0/com1Controller terminal15 pin D-SUB (male)HMI terminal9pin D-SUB female/male

Strona 331 - 4.72 TMCM_303

4 Communication settings and guide of HMI connecting with controller ※P L C A ttr ib u te (station disable) ※N etw ork con figu ration(Note: PLC

Strona 332 - TMCM_303

4 Communication settings and guide of HMI connecting with controller At this time open “indralogic” -->“online/communication parameter” -->“ne

Strona 333 - THINGET Controller protocol

4 Communication settings and guide of HMI connecting with controller 2. “Resource”--->“Global variables”--->declare variable in “HMI” 3. Click

Strona 334 - MODBUS RTU protocol

4 Communication settings and guide of HMI connecting with controller PLC Setting 1. Modify the IP in the controller. 2. Declare variable in controlle

Strona 335 - 4.74 Toledo DLoadCell

4 Communication settings and guide of HMI connecting with controller 2 ) IN Insert IndraMotion MLC L25 properties box, set the Firmware release (FWA-C

Strona 336 - Green(RX

4 Communication settings and guide of HMI connecting with controller 4. Click “online/login” ◎Supported Device Device Bit Address Word Address For

Strona 337 - S2PU72A:

4 Communication settings and guide of HMI connecting with controller NOTE: Baud Rate and Station No. must be the same as the setting in the controlle

Strona 338

4 Communication settings and guide of HMI connecting with controller b. If the "No", the main station or other equipment necessary to config

Strona 339 - - 336

2 Printer connectiong cable diagram 2 Printer Connecting Cable Diagram 2.1 Serial Interface Printer Cable 2.1.1 Brightek thermal printer Users choose

Strona 340 - TRIO protocol

4 Communication settings and guide of HMI connecting with controller 2. Copy “MT5020.EDS” to “C:\Program Files\Common Files\CAA -Targets\ StepServo\

Strona 341 - RS485-4 communication

4 Communication settings and guide of HMI connecting with controller d. choose “CanMaster” right click “Append HMI-MT5020” e. Node ID: set slave sta

Strona 342

4 Communication settings and guide of HMI connecting with controller g. PDO read and write setting h. define Global Variable - 59 -

Strona 343

4 Communication settings and guide of HMI connecting with controller i. SDO setting,this step need program j. load the configuration into the PLC ◎

Strona 344 - 8 pin Mini Din (male)

4 Communication settings and guide of HMI connecting with controller Device Bit Address Word Address Format Notes ———— LW8000~LW8999 DDDD NO

Strona 345

4 Communication settings and guide of HMI connecting with controller RS485 ◎ Supported Device Device Bit Address Word Address Format Notes Inp

Strona 346

4 Communication settings and guide of HMI connecting with controller Special Relay F 0-2047 ------ DDDD Z Register ------ Z 0-1029 DDDD Timer ---

Strona 347

4 Communication settings and guide of HMI connecting with controller Series CPU Link Module COMM Type Parameter Cable Danfoss FC-300 RS485 on t

Strona 348

4 Communication settings and guide of HMI connecting with controller 8-32 FC Port Baud Rate [0] 2400 Baud [1] 4800 Baud *[2] 9600 Baud 8-33 FC P

Strona 349 - 4.79 Vigor Corporation

4 Communication settings and guide of HMI connecting with controller 4. R/W of process word: 1) Address of EPD register is 8000, is for saving input

Strona 350

2 Printer connectiong cable diagram 15 RXD19 GND3 TXD5 GNDBright Printer 20 pin port Note:the red line is the first pinHMI9 pin serial port e. WH-E173

Strona 351 - 4.80 XiLin Inverter

4 Communication settings and guide of HMI connecting with controller ◆Frequency of R W 0 m apping : If input 2000 to R W 0, frequency is 25H Z, and in

Strona 352 - 4.81 Yamatake Corporation

4 Communication settings and guide of HMI connecting with controller loop 0 1 01 Preset reference value LSB 02 Preset reference value MSB 03 DC brak

Strona 353

4 Communication settings and guide of HMI connecting with controller frequency is 25Hz, and “1” in the 29th bit means 12.5Hz, and so on. In short, the

Strona 354

4 Communication settings and guide of HMI connecting with controller DVP RS485-2 communication Note: RS485 communication, we should change the value

Strona 355 - - 352

4 Communication settings and guide of HMI connecting with controller 2. PLC connection with the Wpl207, monitoring changes in the value of D1120. for

Strona 356

4 Communication settings and guide of HMI connecting with controller HMI terminal9pin D-SUB female\maleController RS485 terminal-+1 RX-6 RX+com0/com1

Strona 357

4 Communication settings and guide of HMI connecting with controller Input Register (read only) ------ 3X1-65535 DDDDD Output Register ------ 4

Strona 358

4 Communication settings and guide of HMI connecting with controller 4708H PB Proportional band 1 to 9999, unit is 0.1. In the adjusting mode 4709

Strona 359 - Yaskawa SGDM protocol

4 Communication settings and guide of HMI connecting with controller Address Content Explanation 1000H Process value (PV) Measuring unit is 0.1, u

Strona 360 - - 357

4 Communication settings and guide of HMI connecting with controller used ) in the adjusting mode or 1012H Hysteresis setting value of the 1st ou

Strona 361

2 Printer connectiong cable diagram 3 RXD7 GND3 TXD5 GNDHMI9 pin serial portPrinter25 pin port 2.2 Recommend Optional printer Printer Driver Printe

Strona 362

4 Communication settings and guide of HMI connecting with controller 1026H Upper-limit alarm 2 In the setting mode 1027H Lower-limit alarm 2 I

Strona 363

4 Communication settings and guide of HMI connecting with controller mode 0812H Decimal point position selection Except for the thermocouple B, S

Strona 364 - - 361

4 Communication settings and guide of HMI connecting with controller ETC RS485-2 on the CPU unit EUC RS485-2 on the CPU unit EPC RS485-2 on the CPU

Strona 365

4 Communication settings and guide of HMI connecting with controller ◎Cable Diagram RS485 communication cable com0/com11RX-6RX+5 GNDHMI terminal9pin D

Strona 366 - V series inverter

4 Communication settings and guide of HMI connecting with controller Emerson EC10 RS485-2 communication Emerson EC20 RS485-2 communication NOTE: Co

Strona 367

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Emerson EC10 Device Bit Address Word Address Format Notes Inp

Strona 368 - Yokogawa FA-M3

4 Communication settings and guide of HMI connecting with controller Emerson EC20 Device Bit Address Word Address Format Notes Input Relay X000-377

Strona 369 - Ethernet(TCP Slave)

4 Communication settings and guide of HMI connecting with controller 4.20 Epower ◎Serial Communication Series CPU Link Module Driver Epower Epowe

Strona 370

4 Communication settings and guide of HMI connecting with controller ◎Supported Device Device Bit Address Word Address Format Notes UPSSet UPSSet

Strona 371 - - 368

4 Communication settings and guide of HMI connecting with controller PC terminal9pin D-SUB femaleHMI terminal9pin D-SUB male3 TXD2 RXD5 GND2 RXD3 TXD5

Strona 372

3 Download cable diagram 3 Download Cable Diagram 3.1 Download by Serial Port The COM2 port on the back of the case can be used to connect PLC RS-232

Strona 373

4 Communication settings and guide of HMI connecting with controller FACON FB FB MA FB MC FBs-20MAT RS232 on the CPU unit RS232 Setting Your owner c

Strona 374 - 4.84 YuDian AI

4 Communication settings and guide of HMI connecting with controller Modbus RTU RS485-2 communication Note: The detailed communication configuration

Strona 375

4 Communication settings and guide of HMI connecting with controller PLC Setting 1、 In ether cfg software, click [scan] to search the PLC information

Strona 376 - - 373

4 Communication settings and guide of HMI connecting with controller 3、 Click [ok] to save the settings. ◎Supported Device Device Bit Address Word A

Strona 377 - - 374

4 Communication settings and guide of HMI connecting with controller FBS-CB25-3 module communication RS232 communication cable Controller port1 termin

Strona 378 - - 375

4 Communication settings and guide of HMI connecting with controller NOTE:When PLC is protected by password, protocol time out 2 is 65535, and the re

Strona 379 - 4.85 ZiGuang Ethernet

4 Communication settings and guide of HMI connecting with controller Note:M_special address: 8000 in the PLC corresponds to 0 in the HMI. DW_special a

Strona 380

4 Communication settings and guide of HMI connecting with controller IC693CPU351 IC693CPU352 IC693CPU360 IC693CPU363 IC693CPU364 IC693CPU374 IC693CSE3

Strona 381

4 Communication settings and guide of HMI connecting with controller CPU340 CPU341 CPU350 CPU351 CPU352 CPU360 CPU363 CSE311 CSE313 CSE323 CSE331 CSE3

Strona 382

4 Communication settings and guide of HMI connecting with controller RS485-4 Setting Your owner cable VersaMax Series CPU001/002/005 CPUE05 RS

Komentarze do niniejszej Instrukcji

Brak uwag