SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure, flow and level
DS III series
for differential pressure and flow
2/118
Siemens FI 01 · 2009
Selection and Ordering data Order code
Further designs
HART PA FF
Add "-Z" to Order No. and specify Order
code.
Pressure transmitter with mounting
bracket made of:
•Steel A01 9
9
9
• Stainless steel A02 9
9
9
O-rings for process flanges
(instead of FPM (Viton))
• PTFE (Teflon) A20 9
9
9
• FEP (with silicone core, approved for food) A21 9
9
9
• FFPM (Kalrez, compound 4079)
A22 9
9
9
• NBR (Buna N) A23 9
9
9
Plug
• Han 7D (metal, gray) A30 9
• Han 8U (instead of Han 7D) A31 9
Sealing screws A40 9
9
9
¼-18 NPT, with valve in material of process
flanges
Cable sockets for M12 connectors (metal) A50 9
9
9
Rating plate inscription
(instead of German)
• English B11 9
9
9
• French B12 9
9
9
• Spanish B13 9
9
9
• Italian B14 9
9
9
English rating plate
B21 9
9
9
Pressure units in inH
2
O or psi
Quality inspection certificate (Factory cali-
bration) to IEC 60770-2
C11 9
9
9
Acceptance test certificate C12 9
9
9
To EN 10204-3.1
Factory certificate C14 9
9
9
To EN 10204-2.2
"Functional Safety (SIL)" certificate C20 9
"PROFIsafe" certificate and protocol C21 9
Setting of upper limit of output signal to
22.0 mA
D05 9
Manufacturer's declaration acc. to NACE D07 9
9
9
(only together with seal diaphragm made of
Hastelloy and stainless steel)
Type of protection IP68 D12 9
9
9
(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)
Digital indicator alongside the input keys D27 9
9
9
(only together with the devices 7MF4533-
....2-.A.6 or -.A.7-Z, Y21 or Y22 + Y01)
Use in or on zone 1D/2D E01 9
9
9
(only together with type of protection
"Intrinsic safety (EEx ia)")
Use on zone 0 E02 9
9
9
(only together with type of protection
"Intrinsic safety (EEx ia)")
Explosion-proof "Intrinsic safety" to
INMETRO (Brazil)
E25 9
9
9
(only for transmitter 7MF4...-.....-.B..)
Explosion-proof "Intrinsic safety" to
NEPSI (China)
E55 9
9
9
(only for transmitter 7MF4...-.....-.B..)
Explosion protection "Explosion-proof" to
NEPSI (China)
E56 9
9
9
(only for transmitter 7MF4...-.....-.D..)
Explosion-proof "Zone 2" to NEPSI (China) E57 9
9
9
(only for transmitter 7MF4...-.....-.E..)
Interchanging of process connection side H01 9
9
9
Stainless steel process flanges for
vertical differential pressure lines
H03 9
9
9
Additional data
Add "-Z" to Order No. and specify Order
code.
Measuring range to be set
Specify in plain text:
• With linear characteristic (max. 5 digits):
Y01: ... up to ... mbar, bar, kPa, MPa, psi
Y01 9
• With square-rooted characteristic
(max. 5 digits):
Y02: ... up to ... mbar, bar, kPa, MPa, psi
Y02 9
Measuring point number (TAG No.) Y15 9
9
9
Max. 16 characters, specify in plain text:
Y15: ...........................................
Measuring point text Y16 9
9
9
Max. 27 characters, specify in plain text:
Y16: ...........................................
Entry of HART address (TAG) Y17 9
Max. 8 characters, specify in plain text:
Y17: ...........................................
Setting of pressure indication in pressure
units
Y21 9
9
9
Specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H
2
O
*)
, inH
2
O
*)
, ftH
2
O
*)
,
mmHG, inHG, psi, Pa, kPa, MPa, g/cm
2
,
kg/cm
2
, Torr, ATM or %
*) ref. temperature 20 °C
Setting of pressure indication in
non-pressure units
Y22 +
Y01 or
Y02
9
Specify in plain text:
Y22: ..... up to ..... l/min, m
3
/h, m, USgpm, ...
(specification of measuring range in pressure
units "Y01" or "Y02" is essential, unit with
max. 5 characters)
Preset bus address Y25 9
(possible between 1 and 126)
Specify in plain text:
Y25: .....................
Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset
9
= available
Selection and Ordering data Order code
Further designs
HART PA FF
Add "-Z" to Order No. and specify Order
code.