Setup
85
Siemens Building Technologies
Fire Safety & Security Products 08.2007
10.2 SISTORE MX NVS - IP camera - CKA4810/20
Abb. 12 SISTORE MX NVSIP camera –– CKA4810/20 system overview
1 CKA4810/20
2 MX NVS server
3 Max. 32 IP cameras
Prerequisite:
The CKA driver is installed (see Section 6.2: Subsequently installing a hardware
driver).
1. Connect the CKA4810/4820 control panel (COM1A port) to the MX NVS
server (COM1/COM2).
2. Configure COM1A on the control panel as an RS232 interface. For more
information please refer to the respective instruction manual for control panel
CKA4810 / CKA4820.
3. Start the SISTORE MX NVS application software.
4. Switch to configuration mode.
5. Mark the checkbox CCTV keyboard on the System tab.
6. Click Apply.
Î The setting will be saved.
Î The interface for the control panel is enabled.
Connections
Signal MX NVS Server
SISTORE RemoteView
CKA4810 / CKA4820
9-pin SubD connector
GND 5 5
RXD 3 2
TXD 2 3
Interface configuration CKA4810 / CKA4820
z Protocol: SIMATRIX RS232 or SIEMENS IVM
z Baud rate: 9600
z Parity: none