Device Bit Address Word Address Format Notes
Output bit 0X1-65535 ------ DDDDD
Input bit (read only) 1X1-65535 ------ DDDDD
Input Register (read only) ------ 3X1-65535 DDDDD
Output Register ------ 4X1-65535 DDDDD
Controller Setting
1. Set the communication parameter
Setting communication parameter in “setting mode”
(1)
(Station number) matching the station No. of the Ev5000
(2)
(Baudrate)
(3)
(Data bit)
(4)
(Parity)
(5)
(Stop bit)
Non-supported formats: 7, N, 1 or 8, O, 2 or 8, E, 2(Databit、Parity、Stopbit).
(6) Setting the parameter of CoSH
The data must be ON when executing write operation in touch-screen.
2. Communication parameters and notes
DTA4848:Address and Content of Word Register (corresponds to 4X in the HMI)
Address Content Explanations
4700H Process value (PV)
4701H Set point (SV)
4702H Upper-limit alarm 1
In the running mode
, when ALA1 is 1 and
Upper-limit alarm is valid.
4703H Lower-limit alarm 1
In the running mode
, when ALA1 is 1 and Lower
-limit alarm is valid.
4704H Upper-limit alarm 2
In the running mode
, when ALA2 is 2 and
Upper-limit alarm is valid.
4705H Lower-limit alarm 2
In the running mode
, when ALA2 is 2 and Lower
-limit alarm is valid.
4706H Upper-limit of temperature range The data content should not be higher than the temperature