Configuration of cash dispenser mode
155
Siemens Building Technologies
Fire Safety & Security Products 03.2009
The following settings can be made in this window:
Note
The IBM, IBM_PBM, SNI_PBM, DIEBOLD, KEBA_GAA and ASCOM cash dispenser types work
according to the PBM (Personal Banking Machine) protocol from IBM. The settings options of these
cash dispenser types can differ a little from the settings options of the PBM type.
Picture per step/Telegram
Indicate here how many images per step/telegram are to be recorded.
Picture recording
The image recording for the images 1, 2 and 3 (or for the image group if multiple
images are recorded from one camera or various cameras for a telegram) will be
initiated based on the step ID, i.e. the step ID determines whether and when an
image or an image group is recorded. The setting for which steps are used is made
here with three configurable steps:
z First picture from step: for the first image recording
z Second picture from step: for the second image recording
z Third picture from step: for the third image recording
If no step is specified for the third image or for the image group, image 3 will be
recorded at a delay time (VZ_BILD_BILD) from image 2 which can be set in the
configuration.
Note
In order for the cash dispenser link to ensure secure operation, at least two fields (step 3 and 10 or
11) in the cash dispenser must be enabled!
The enabling takes place directly on the cash dispenser via the “CI”. This involves the configuration
file “Custom.dat”.
Time
The following settings can be made in the Time group field:
z Time synchronization:
If multiple cash dispensers are connected to a SISTORE MX NVS system this
specification can define which ones synchronize the SISTORE MX NVS system.
We recommend enabling time synchronization only for one interface (one cash
dispenser); if the cash dispensers have different times, this is urgently
necessary.
z Timeout:
After a set timeout period an active transaction is automatically ended. This is
necessary in order to close transactions properly for which the last specified step
is missing, for example with an account balance query. The specification of the
timeout is in seconds.
TIMEOUT=300
If a transaction is ended by a timeout, an archive entry with status=2 is made.
z Timestep:
The TIMESTEP parameter can determine which telegram is used for the
synchronization. This is to achieve optimal agreement of the time between the
SISTORE MX NVS archive and the cash dispenser journal.
Delay of picture recording
The following fields can be used to define the delay times in seconds between the
arrival of the telegram and the actual recording of the image:
z Portrait
z Cash
z Room
z Picture to picture