GAS CHROMATOGRAPHY
p
process
ADVANCE NETWORK COMMUNICATIONS
BOARD/DATANET (ANCB/DN)
User’s Manual Edition 1/2007
Przeglądanie stron 0
1 2 3 4 5 6 ... 71 72

Podsumowanie treści

Strona 1 - process

GAS CHROMATOGRAPHY p processADVANCE NETWORK COMMUNICATIONS BOARD/DATANET (ANCB/DN) User’s Manual Edition 1/2007

Strona 2

Safety Practices and Precautions, Continued Correct Operating Voltage Before switching on the power, check that the operating voltage listed on the e

Strona 3 - Board/DataNET (ANCB/DN)

Chapter 1 Installation Overview Description The Advance Network Communications Board DataNET (ANCB/DN) board plugs into the backplane of an Advance M

Strona 4 - Copyright Notice

Overview, Continued Figure 1 shows Advance Maxum and Advance Optichrom GC’s communicating on an ACS via a DataNET link. Advance MaxumApplied Automati

Strona 5 - Table of Contents

ANCB/DN Specifications Protocol and Addressing Open Systems standard TCP/IP protocol and addressing (Transmission Control Protocol/Internet Protocol

Strona 6

ANCB/DN Specifications, Continued Cable Types The following Table should be used when evaluating or selecting cable for an existing or new installati

Strona 7 - Preface

ANCB Installation Description The ANCB is installed into slot 1 of the Advance Maxum’s or NAU’s System Controller (SYSCON). To install the ANCB it i

Strona 8 - Technical Support

ANCB Installation, Continued Instructions, continued Step Procedure 4. Press the ANCB straight into slot 1. Make sure that you push evenly on b

Strona 9

Site Wiring Requirements Description The type of wiring is dependent upon the site requirements: • CE (Conformite Europeene) Certified Areas • NEC

Strona 10

Site Wiring Requirements, Continued DataNET Channels The DataNET channel connections can be either copper wire or fiber optic cable. The wiring metho

Strona 11 - Chapter 1

Site Wiring Requirements, Continued Table 1-1: Recommended DataNET Cable, Continued Cable Type Vendors & P/N Installation Notes Twisted Pair

Strona 13 - ANCB/DN Specifications

Site Wiring Requirements, Continued Use approved flexible non-metallic conduit wiring method. Conduit may contain multiple cables. For CE installatio

Strona 14 - Cable Types

CE Installations Description This section should be used for installation sites that must conform to CE (Conformite Europeene) Certification. Typical

Strona 15 - ANCB Installation

CE Installations, Continued 3. A split ferrite filter must be clamped to DataNET copper wire and fixed immediately to the outside of the unit; use p

Strona 16 - CROSSOVER

DataNET Connections Description This section provides instructions for connecting a Maxum or NAU to a DataNET network. All DataNET connections are ma

Strona 17 - Site Wiring Requirements

DataNET Copper Connections Before You Begin This section provides instructions for connecting the Maxum to a DataNET network. All DataNET connections

Strona 18 - DataNET Channels

DataNET Copper Connections, Continued Instructions, continued Step Action 3. Strip the insulation ¼ -inch back from each of the incoming copper

Strona 19 - Requirements

DataNET Fiber Optic Connections The Fiber Optic Coupler is mounted in a threaded, potted, gas tight fitting assembly designed for use in hazadrous ar

Strona 20 - Cable Connections

DataNET Fiber Optic Connections, Continued The DataNET Fiber Optic Couplers use ST-style connectors (twist & lock). Always insure that the TX (T

Strona 21 - CE Installations

DataNET Fiber Optic Connections, Continued Installation Instructions Step Action 1. Ensure that the ANCB is installed in slot 1 of the SYSCON. 2.

Strona 22 - CE Installations, Continued

DataNET Fiber Optic Connections, Continued Instructions, continued Step Action 4. Connect the incoming Fiber Optic cable transmit and receive lin

Strona 23 - DataNET Connections

Advance Network Communications Board/DataNET (ANCB/DN) Revised Printing – January 2007 User’s Manual 2000592-001

Strona 25 - Instructions

Chapter 2 Data Communications Setup Introduction Overview This chapter provides maintenance personnel instructions for making the operational setting

Strona 26

Configuring Your PC Description The Advance Network Communications Board (ANCB) has a built-in utility for configuring the unit. The Windows® HyperTer

Strona 27

Configuring Your PC, Continued 5. Click OK. The Connect To dialog box opens. 6. From the Connect using scroll list choose the COM port you will be

Strona 28 - CONNECTOR

Configuring Your PC, Continued 8. Scroll each field and select the following Port Settings: Bits per second: 57600 Data Bits: 8 Parity: None Stop bi

Strona 29

Configuring Your PC, Continued 11. Click Settings tab. The settings screen will appear. 12. From the Emulation scroll list select VT100. Do not cha

Strona 30

Configuring Your PC, Continued 14. Ensure that the following default settings are set: Cursor: • Underline √ Blink Terminal Mode: none Character set:

Strona 31 - Chapter 2

Establishing a Connection Description Once your PC is set up, as described in Configuring Your PC, you are ready to connect to the Advance Maxum or N

Strona 32 - Configuring Your PC

Establishing a Connection, Continued Password Format A password name can consist of any combination of alphanumeric characters. The alphanumeric name

Strona 33

Establishing a Connection, Continued 3. At the > prompt type: login password and press ↵ Enter. The Connect Screen will appear with the login inf

Strona 34

Copyright Notice © 2002-2007 by Siemens All rights reserved. This publication is for information only. The contents are subject to change without noti

Strona 35

Setting Network Address Description This section provides instructions to configure the ANCB/DN. Command Line Definitions Chapter 3, Command Line Su

Strona 36

Setting Network Address, Continued See Assigning an IP Address, page 32 to learn how to assign an IP Address. Learning Hint 4. To configure the ANC

Strona 37 - RS232 PORT

Assigning an IP Address Overview Each DataNET device must have a unique IP address. This 32-bit number defines each devices network ID and host ID. T

Strona 38 - How to Log On

Firmware Updates Description Periodically we will provide our users with firmware upgrades. Perform the following instructions to download a new firm

Strona 39 - Remote Connection

Firmware Updates, Continued 6. Click on Send Text File. The Send Text File dialog box will appear. Choose the directory on your PC where the ANCB fi

Strona 40 - Setting Network Address

Chapter 3 Command Summary Command Descriptions Description This chapter is intended for maintenance personnel. This chapter provides definitions for

Strona 41

Command Descriptions, Continued logout Log out of device. netstat hdlc Display DataNET link statistics for all ports. netstat hdlc clear Display and

Strona 42 - Assigning an IP Address

Command Descriptions, Continued config address ip This command sets the device IP address. Each device in the system must have a unique IP address.

Strona 43 - Firmware Updates

Command Descriptions, Continued display links This command displays the ANCB/DN link state table. The link state table indicates, for each link, whet

Strona 44 - Firmware Updates, Continued

Command Descriptions, Continued “hdlc” Command This command may be used to override default values for several parameters related to the DataNET pr

Strona 45 - Chapter 3

Table of Contents Preface iiiTechnical Support ivSafety Practices and Precautions v Chapter 1: Installation 1Overview 1ANCB/DN Specifications

Strona 46

Command Descriptions, Continued download Use this command to load new software into the device via the RS-232 Configuration port. The procedure for s

Strona 47

Command Descriptions, Continued local> list 155 msg | source | destination | size | source port | time stamp 155 | Trace e

Strona 48

Command Descriptions, Continued login The login command allows the user to access all the ANCB parameters and diagnostic information. The format is:

Strona 49 - “hdlc” Command

Command Descriptions, Continued Example: local> netstat dn 1 DataNET Statistics for DN link 1 Frames Sent 855 Frames Sent/Retried 0 Frame

Strona 50

Command Descriptions, Continued reset This command resets and saves the configuration parameters in non-volatile memory. test This command places a

Strona 51

Chapter 4 Troubleshooting Introduction Overview This chapter provides installation personnel with troubleshooting information to solve problems assoc

Strona 52

ANCB Description Description The DataNET ANCB (Advance Network Communication Board) provides the communications electronics for the unit. The ANCB plu

Strona 53 - “port” Command

ANCB Description, Continued Jumper J2 Settings The ANCB provides a set of impedance matching jumpers to simplify the cable interfacing process. Jump

Strona 54

ANCB Description, Continued Jumper J5 Settings The ANCB jumper settings for J5 are factory set and dependent upon the product the ANCB will be used i

Strona 55 - Chapter 4

ANCB LEDs Description and Operation Description This section provides maintenance personnel with information on how to use the ANCB LEDs for troubles

Strona 57 - ANCB Description, Continued

ANCB LEDs Description and Operations, Continued Figure 4-2 shows the edge visible LEDs on the ANCB. The LED labels are silk-screened adjacent to each

Strona 58

ANCB LEDs Description and Operations, Continued ANCB Ethernet Controller LEDs Each ANCB provides two Ethernet ports a 10BaseT and 10Base2. Each port

Strona 59 - Board LEDs

DataNET Troubleshooting Guide Instructions If a DataNET communications link fails to establish check for a: • configuration conflict, • link signal

Strona 60

DataNET Troubleshooting Guide, Continued Configuration Parameter Errors The device may have an invalid or duplicate IP address, Subnet mask or iprou

Strona 61 - Controller LEDs

DataNET Troubleshooting Guiding, Continued If the ANCB_DN port LED is never green, or intermittently flashes between green and red, there may be a si

Strona 62 - Wrong Hub or Port

Chapter 5 Parts Catalog Introduction Overview This chapter is intended for maintenance personnel. The Chapter provides a list of replaceable parts an

Strona 63

Available Parts Description The following spare parts are available. Part Description Ordering Number ANCB Communication Board; DataNET 2020951-004

Strona 64 - Problems

Glossary Definitions Overview This section defines important Terms. The Advance Network Gateway Ethernet (ANG_EN) is a wall- (or rack-) mounted unit

Strona 65 - Chapter 5

Definitions, Continued A Late Collision is one that occurs after the first 64 bytes in a frame or packet. Since the smallest Ethernet frame (packet)

Strona 67 - Glossary

Preface Audience & Purpose This manual is intended for maintenance personnel and describes how to install the Advance Network Communication Boar

Strona 68 - Definitions, Continued

Siemens Energy & Automation, Inc. 7101 Hollister Road, Houston, TX 77040 Phone 713-939-7400, Fax 713-939-9050

Strona 70

1/2007 Edition 2000592-001Siemens Energy & Automation, Inc.7101 Hollister Road, Houston, TX 77040United StatesPhone +1 (713) 939-7400Fax +1 (713

Strona 71

Technical Support Getting Help At Siemens Energy & Automation, Inc. we take pride in the on going support we provide our customers. When you purch

Strona 72 - 1/2007 Edition 2000592-001

Safety Practices and Precautions Safety First This product has been designed and tested in accordance with IEC Publication 1010-1, Safety Requiremen

Komentarze do niniejszej Instrukcji

Brak uwag