Technical data
3RG78 47–4BB standard evaluation unit
3RG78 47 intelligent evaluation units
Safety cat. acc. to EN 954-1 Category 4
STOP cat. acc. to EN 60 204-1(11/98)
STOP category 0
Operational voltage U
B
AC/DC 24 V, –15% to +10%
Residual ripple (for DC)/
2.4 V
pp
Frequency (for AC) 50 to 60 Hz
Clearance and leakage paths
4 kV acc. to DIN VDE 0110 (04.97)
Power consumption
2.1 W (for AC)/1.7 W (for DC)
External protection for
supply circuit
1 A slow
Output contacts
2 NO,
1 NC AgSnO
2
, gold plated
Switching capacity to IEC 60 947-5-1
•AC-15, 230 V 6 A
DC-13, 24 V (360 operating cycles/h)
6 A
DC-13: 24 V (3600 operating cycles/h)
3 A
Max. continuous current per current path
6 A
Contact protection per current path
6.3 A quick or 4 A slow
Max. total current for all current paths
12 A
Max. switching frequency
3600 operating cycles
Mechanical endurance
10 × 10
6
operating cycles
Pick-up delay
•Manual start 70 ms
•Automatic start
230 ms
Release delay, response time
20 ms
Minimum on-time S34, S35
80 ms
Electronic backup:
start/restart time
2 s/2 s
Control voltage/current
on S11, S22, S31
DC 24 V/20 mA
Permissible input conductor resistance
< 70
Emitted interference EN 50 081-1, -2
Interference immunity
EN 50 082-2
Operating temperature
–25 °C to + 55 °C
Degree of protection
Housing IP 40, terminals IP 20
Conductor cross-sections
•finely stranded 2 × 0.14 to 0.75 mm
2
•finely stranded with end sleeve 2 × 0.25 to 0.5 mm
2
•finely stranded with twin end sleeve 2 × 1.5 mm
2
•solid 1 × 0.14 to 2.5 mm
2
•finely stranded with end sleeve 2 × 0.25 to 2.5 mm
Protection acc. to EN, IEC 61496 T1 Typ e 4
Safety category acc. to EN 954-1
Category 4
STOP cat. acc. to EN 60 204-1(11/98)
STOP category 0
Supply voltage
24 V DC, ± 20%,
external power pack with safe
isolation from the supply and
bridging of 20 ms voltage drop is
necessary
Current consumption
Approx. 200 mA without ext. load
External protection (power supply)
2.5 A mT
Safety sensors that can be connected
(expanded versions)
1 light curtain, Type 4, or
up to 2 light curtains of Type 2
(all acc. to IEC 61496)
up to 2 light curtains of Type 4, or
up to 4 light curtains of Type 2
(all acc. to IEC 61496)
Tes t o u tputs T1 and T2, test interval
200 ms
Available functions
•All versions Start/restart inhibit,
contactor control, diagnosis
•Versions with cycle control
Protection, single-pulse and two-
pulse mode
•Versions with muting function
Sequential muting, parallel muting,
parallel double muting
(only 3RG78 47-4.G)
Control input:
contactor control (EDM)
Feedback of positively-driven
contacts of downstream contactors
Control input:
start/restart inhibit (Reset)
Floating NO
(button or key-switch)
Connection of muting sensors that
cannot be tested
Signal level in damped state: active
high, +24 V
Connection of muting sensors that can
be tested
active high, +24 V, plus test pulses
T1 or T2
Outputs: Muting displays for lamps 24 V,
max. 5 W
pnp switching outputs
muting function On,
active high, +24 V,
200 mA max.
Signal outputs (acc. to variants)
Light curtain free/interrupted;
switching state relay/transistor
output; restart inhibit locked/
unlocked; status of muting function;
muting error; warning muting lamp
defective; internal errors, etc.
Operating temperature
0 to +55 °C
Degree of protection
IP 20, must be installed in
switchgear cabinet or housing to
IP 54 degree of protection upward
s
Installation
Mouting on 35 mm standard
mounting rail
Connection technique
Plug-in coded screw-type terminals
up to 2.5 mm
2
Outputs Relay outputs Semiconductor outputs
OSSD safety outputs
2 safety-related NO contacts 2 safety-related pnp semiconductor outputs with
crossover detection
Switching voltage/Switching current
60 V DC, 250 V AC, max.´6 A 24 V DC, max. 300 mA
Only extended versions
1 safety-related NC contact,
60 V DC, 250 V AC, max. 6 A
minimum switching current 20 mA
OSSD external protection 6 AT
OSSD response time of SIGUARD evaluation unit
(without light curtain)
•for light curtain, Type 4, with semiconductor output 18 ms 8 ms
•for light curtain, Type 2
54 ms 44 ms
•for safety switches
54 ms 44 ms
OSSD reactivation time
100 ms 100 ms
OSSD suitable spark quenching
via the coils of the downstream relay
necessary
Introduction
SIGUARD Safety Systems—Safety Integrated
3RG784 SIGUARD Safety Light Curtains and Light Arrays