Preset Congurations (short commands)
In programming mode, you can select different
congurations by using short codes. After select-
ing the pre-dened conguration the reader will
return to programming mode.
These are key presses and after pressing A there
is only one key press between values 0 to 9.
Com-
mand
Function
A1 Precongured interface BCLINK (for
SiPass Entro/Bewator Entro)
A2 Precongured interface 12 (26 bit
Wiegand)
A3 Precongured interface BE (Clock &
Data)
A4 Precongured interface 59 (48 bit
Wiegand for Granta)
The Precongured interfaces is stored in non-vola-
tile memory. Any other parameters such as LED
control and horn control will be dened later and
will only apply for A2, A3 and A4.
A3 Precongured is interface BE (Clock & Data),
with external control of Red LED, Green LED and
Horn. Also, the yellow LED is not active at all,
showing no indication of noise or key presses.