Technical data
Power supply: 12 -24 V DC
Min. 10,5 V DC
Max. 35V DC
Power consumption PP500-EM:
24V DC: Typ 17 mA (408 mW), Max*): 31 mA (744 mW)
12V DC: Typ 32 mA (384 mW), Max*): 68 mA (816 mW)
*) While horn sounds
Power consumption PP500-Cotag:
24V DC: Typ 23 mA (552 mW), Max*): 40 mA (960 mW)
12V DC: Typ 44 mA (528 mW), Max*): 90 mA (1080 mW)
*) While horn sounds
Frequency range: EM: 125 kHz
Cotag: 66-132 kHz
Temperature range: -30° C to +50° C
IP Class: IP54
Dimensions (HxWxD) mm: 140x80x40
If needed, complete the installation with ush mounting
kit BB3.
Reading distances
EM4102 (passive): up to 5 cm
Cotag (passive): up to 5 cm
Cotag (active): up to 10 cm