3.6.3.3 Measuring cell for level

Pressure cap Seal diaphragm on the measuring cell
O-ring Filling liquid of the measuring cell
Measuring cell body Capillary tube with the fill fluid of the mounting
flange
Overload diaphragm Flange with a tube
Differential pressure sensor Seal diaphragm on the mounting flange
Figure 3-9 Function chart of the measuring cell for level
The
inlet pressure (hydrostatic pressure) works hydraulically on the measuring cell through
the seal diaphragm on the mounting flange .
Differential pressure at the measuring cell is transmitted to the differential pressure sensor
through the seal diaphragms and the filling liquid .
When measuring limits are exceeded, the overload diaphragm is displaced until one of
the seal diaphragms or rests on the measuring cell body . The seal diaphragms
⑥ thus protect the differential pressure sensor from overload.
The seal diaphragm is displaced by the differential pressure. The displacement changes
the resistance of the four doped piezoresistors in the bridge circuit.
The change in the resistance causes a bridge output voltage proportional to the differential
pressure.
Description
3.6 Functional principle
SITRANS P, DS III series with HART
Operating Instructions, 09/2012, A5E00047092-08 27