Technical Product Manual
Fault analysis and repairs 1318
5 Sealing points
Section 5: Sealing points • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 5 5–7
5.4.4 Fitting hood fixing caps
Fig. 5-6 Fitting hood and fixing caps
Procedure
Put the hood (1) on correctly (make a note of the threaded pins (3) and
trough connector (5))
1
and press it on to the stop.
Fit the embossed fixing caps (2) as shown in Fig. 5-8.
Screw the special tool (4) onto the threaded pins (3) until the
fixing cap (2) is flush with the hood surface (6).
(See Fig. 5-6)
2
3
4
3
2
1
5
3
2
6
1 Hood 4 Special tool
2 Fixing caps 5 Trough connector
3 Threaded pins 6 Hood surface
Note
The top surface of the fixing cap (2) must not be distorted when fitting it.
1 from 02.94: integrated into the hood