2 Removing and fitting housing cover
2–14 Section 2 © Siemens VDO Trading GmbH TU00-1318-0200302
2.5 Removing indicators and dial components
Fig. 2-9 Removing indicators
2.5.1 Speed indicator
Procedure
Remove the cap (2) by hand.
Insert the indicator remover (1) exactly in the middle.
Turn the indicator extractor (1) clockwise.
Remove the speed indicator (3).
2.5.2 RPM indicator
Procedure
Turn the RPM indicator (5) and the ring (4) and remove by hand.
1 Indicator extractor 7 Washer
2 Cap 8 Ring *
3 Speed indicator 9 Minute hand *
4 Ring 10 Ring *
5 RPM indicator 11 Hour hand *
6 Second washer
6,
2
2
1
2
6
7
8
9
10
11
3
4
5
4
19
Remark
Items 8-11*
From 04.01 indicators and rings can only be ordered together.