Page 166 HydroRanger 200 – INSTRUCTION MANUAL 7ML19981FC01
mmmmm
Parameters
Totalizer (P630 to P645)
P630 LCD Totalized Multiplier
Use this feature if the LCD Total increments by too large (or too small) an amount.
Enter the factor (powers of 10 only) by which actual volume is divided, prior to display on
the LCD. Use a value such that the eight-digit totalizer doesn’t roll over between readings.
Example:
For an LCD Total display in 1000s of volume units, enter 3.
Primary Index Global
Values
-3 .001
-2 .01
-1 .1
0*1
110
2100
3 1000
Values
4 10,000
5 100,000
6 1,000,000
7 10,000,000
Related LCD Totalizer (P322 and P323)