Model Designations and Specifications UMSITRPDS3-1
November 2010
9-2
9.1 MODEL 7MF4033, GAGE PRESSURE
This section contains a dimension drawing of the transmitter, a model designation table and performance
specifications.
1
2
3
Process connection, ½ -14NPT, connection shank
G1/2A or oval flange
Blanking plug
Electrical connection:
Screwed gland Pg 13.5 (adapter)
Screwed gland M20 x 1.5 or
Screwed gland ½ -14NPT or
Han 7D/Han 8 U-plug
4
5
6
7
Connector side
Electronics side, digital display (greater length for
cover with window)
Access cover over magnetic pushbuttons
Mounting bracket (optional)
This Figure is for Models 7MF4033 and 7MF4233.
FIGURE 9-1 Model 7MF4033, Dimensions