Configuration Using Web Based Management and the Command Line Interface
C79000-G8976-C184-07
214
ce Syntax of the Command Line Interfa
CLI\IFEATURES\IQOS\WLAN1>
or for the second wireless adapter (if it exists)
CLI\IFEATU LAN2> RES\IQOS\W
Command Description Comment
iqos [E|D]
Enables / disables iQOS
functionality.
static [E|D]
e.
Enables / disables the calculation of
the minimum transmission rat
response [response time]
Specifies the response time for a
client with bandwidth reservation.
15 – 1000 ms, default
50 ms
add <MAC> <Max_BW> <E|D>
Creating a critical client.
edit <index> <Max_BW>
Changes the setting of a client
<E|D>
delete <Index>
Deletes a critical client
clearall
Deletes all critical clients
Operating Instructions SCALANCE W78x