Configuring with Web Based Management
5.5 "System" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
183
Description
The table has the following columns:
Port
Shows the available ports.
Setting
Select the setting from the drop-down list. You have the following options:
Up
Error handling is triggered when the port changes to the active status.
(From "Link down" to "Link up")
Down
Error handling is triggered when the port changes to the inactive status.
(From "Link up" to "Link down")
"-" (disabled)
The error handling is not triggered.
Procedure
1. From the relevant drop-down list, select the options of the slots / ports whose connection
status you want to monitor.
2. Click the "Set Values" button.
5.5.16
PNIO
Settings for PROFINET IO
This page shows the PROFINET IO AR status and the device name.