Industrial Wireless Communication
IWLAN – Client Modules IEEE 802.11n
SCALANCE W748 M12 for indoor use
6
Function
Mobile controls in an automated guided vehicle system
The controllers log on in the RF field via the Ethernet client
modules W748-1 M12, which are mounted directly on the
vehicle, and can move around freely within this field. This, for
example, makes it possible to operate an automated guided
vehicle system.
Radio cell 1 Radio cell 2
Automated Guided Vehicle System (AGVS)
G_IK10_XX_30282
Industrial Ethernet
S7-400
SIMATIC HMI
Access Point
SCALANCE
W788-2 M12
Access Point
SCALANCE
W788-2 M12
Client Module
SCALANCE
W748-1 M12
Client Module
SCALANCE
W748-1 M12
Client Module
SCALANCE
W748-1 M12
Field PG/
Notebook
PC
PC
SIMATIC HMI
PC
SIMATIC HMI
S7-300
SCALANCE
X208
S7-300
SCALANCE
X208
S7-300
SCALANCE
X208
SIMATIC HMI