Siemens OSM Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Networking Siemens OSM. Siemens OSM User manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Preface, Contents
Introduction
1
Important OSM/ESM Functions
2
Command Interpreter (CLI)
3
Web-Based Management (WBM)
4
SNMP and RMON
5
Upgrading/Downloading Software
6
Notes on Troubleshooting
7
Appendix
Internet Browser Settings
A
Connecting a PC with
Hyperterminal to the Serial Port
of the OSM/ESM
B
References
C
Abbreviations/Acronyms
D
Glossar, Index
Release 11/2003
C79000-G8976-C137-08
Industrial Ethernet OSM/ESM
Network Management
User Manual
SIMATIC NET
Przeglądanie stron 0
1 2 3 4 5 6 ... 157 158

Podsumowanie treści

Strona 1

Preface, ContentsIntroduction1Important OSM/ESM Functions2Command Interpreter (CLI)3Web-Based Management (WBM)4SNMP and RMON5Upgrading/Downloading Sof

Strona 2

viiIndustrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Preface i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 3

Web-Based Management (WBM)4-39Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08StatusShows the status of each FDB entry.”learned” mea

Strona 4

Web-Based Management (WBM)4-40Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.10.2 Static FDB TableClicking the Static FDB Table m

Strona 5

Web-Based Management (WBM)4-41Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.10.3 FDB Unicast ConfigurationFigure 4-25 FDB Unicas

Strona 6 - Scope of the Manual

Web-Based Management (WBM)4-42Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Deleting Static Unicast AddressesFollow the steps outl

Strona 7 - Target Group

Web-Based Management (WBM)4-43Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.10.4 FDB Multicast ConfigurationClicking the FDB Mul

Strona 8 - Audience

Web-Based Management (WBM)4-44Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Entering a Multicast AddressFollow the steps outlined

Strona 9 - Further Support

Web-Based Management (WBM)4-45Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.11 Port StatusClicking the Ports menu opens the wind

Strona 10 - C79000-G8976-C137-08

Web-Based Management (WBM)4-46Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Flow CtrlThis shows whether or not flow control was ac

Strona 11

Web-Based Management (WBM)4-47Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.11.1 Port ConfigurationIn the Port Configuration win

Strona 12

Web-Based Management (WBM)4-48Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-087. If autonegotiation is disabled, you can set the tra

Strona 13 - Introduction

viiiIndustrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-083.2 Password Protection 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 14 - 1.1.1 Function

Web-Based Management (WBM)4-49Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.12 Statistics CountersThe OSM/ESM has internal stati

Strona 15 - Making Settings

Web-Based Management (WBM)4-50Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.12.1 Packet SizeThe Packet Size window displays the

Strona 16

Web-Based Management (WBM)4-51Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.12.2 Packet TypeThis window displays the packets of

Strona 17 - 1.2.2 Network Management

Web-Based Management (WBM)4-52Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.12.3 Packet ErrorFor each port, the OSM/ESM can dete

Strona 18

5-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08SNMP and RMON5

Strona 19

SNMP and RMON5-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-085.1 SNMPWith SNMP (Simple Network Management Protocol), a network ma

Strona 20 - 1.4 Setting the IP Addresses

SNMP and RMON5-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-085.2 RMONA RMON-compliant device (RMON = Remote MONitoring) allows yo

Strona 21 - Important OSM/ESM Functions

6-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Upgrading/Downloading Software6

Strona 22 - 2.1 Autonegotiation

Upgrading/Downloading Software6-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-086.1 General IntroductionThe firmware of the OSM/ESM

Strona 23 - 2.2 Autocrossover

Upgrading/Downloading Software6-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-086.2 Downloading the Firmware via the Serial PortTo

Strona 24 - Restore Factory Defaults

ixIndustrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-085.2 RMON 5-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 25

Upgrading/Downloading Software6-4Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08The following message is then displayed in the term

Strona 26

Upgrading/Downloading Software6-5Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08The following dialog box then appears displaying th

Strona 27

Upgrading/Downloading Software6-6Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-086.3 Downloading Firmware from an TFTP ServerTo down

Strona 28 - 2.6 Locked Ports

Upgrading/Downloading Software6-7Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08NoteCopy the program file to the TFTP server so tha

Strona 29 - 2.7 Mirroring

7-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Notes on Troubleshooting7

Strona 30 - 2.8 Traps

Notes on Troubleshooting7-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Table 7-1 below lists remedies if you encounter problems

Strona 31 - 2.9 E-Mail Function

Notes on Troubleshooting7-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Table 7-1 TroubleshootingNo. RemedyPossible CauseProblemT

Strona 32 - 2.10 Event Log Table

Notes on Troubleshooting7-4Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Table 7-1 TroubleshootingNo. RemedyPossible CauseProblem8

Strona 33

A-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Internet Browser SettingsTo use Web-Based Management with the OSM/ESM, you must m

Strona 34 - 2.12 Flow Control

Internet Browser SettingsA-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08A.1 Microsoft Internet Explorer 6.0You can check whether

Strona 35 - 2.13 BOOTP/DHCP

1-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Introduction1

Strona 36

Internet Browser SettingsA-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084. Add the IP address of the OSM/ESM to the zone of trus

Strona 37 - 2.15 TELNET

Internet Browser SettingsA-4Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-085. Enter the IP address of the OSM/ESM as shown in Figur

Strona 38 - Redundant Coupling

Internet Browser SettingsA-5Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-088. Activate Active Scripting, see Figure A-4.Figure A-4

Strona 39 - 2 ITP XP standard cable 9/9

Internet Browser SettingsA-6Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-0810.Open the Edit Permissions window, see Figure A-5. If

Strona 40

Internet Browser SettingsA-7Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-0812.Select Tools -> Internet Options -> Advanced

Strona 41 - 2.17 Observer Function

Internet Browser SettingsA-8Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-0813.If you use a proxy server that only accepts DNS regis

Strona 42

Internet Browser SettingsA-9Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Figure A-8 Microsoft Internet Explorer 6.0 - LAN Setting

Strona 43

Internet Browser SettingsA-10Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Figure A-9 Proxy Settings15.In this window, enter the a

Strona 44 - Command Interpreter (CLI)

Internet Browser SettingsA-11Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08A.2 Netscape Communicator 6.21. Select Edit -> Setti

Strona 45 - 3.2 Password Protection

Internet Browser SettingsA-12Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08To do this, select Edit -> Settings -> Advanced -

Strona 46 - 3.3 Installing the CLI

Introduction1-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-081.1 Network Management with SNMPThe Industrial Ethernet OSMs (Optical

Strona 47 - 3.4 Login

B-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Connecting a PC with Hyperterminal to theSerial Port of the OSM/ESMB

Strona 48 - 3.5 CLI Commands

Connecting a PC with Hyperterminal to the Serial Port of the OSM/ESMB-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08You require a

Strona 49 - CLI Menus and Description

Connecting a PC with Hyperterminal to the Serial Port of the OSM/ESMB-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Follow the st

Strona 50 - Start Menu

C-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08ReferencesC

Strona 51 - System Menu

ReferencesC-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08/1/ SIMATIC NET Industrial Ethernet OSM/ESM Operating Instructions, s

Strona 52 - Command CommentDescription

D-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Abbreviations/AcronymsD

Strona 53 - OSM/ESM Menu

Abbreviations/AcronymsD-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Abbreviation/AcronymDefinitionASCII American Standard Code

Strona 54

Abbreviations/AcronymsD-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Abbreviation/AcronymDefinitionSMTP Simple Mail Transfer Pro

Strona 55 - Agent Menu

Glossary-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08GlossaryAutocrossoverCapability of automatically crossing over the send an

Strona 56

GlossaryGlossary-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Boot softwareThe boot software is software integrated on the OSM/E

Strona 57

Introduction1-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-081.1.2 CommunicationProtocolSNMP uses the connectionless protocol UDP

Strona 58 - Switch Menu

GlossaryGlossary-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08ESMSIMATIC NET Industrial Ethernet Electrical Switch Module (has o

Strona 59

GlossaryGlossary-4Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Half duplex flow controlsee Back pressureHTMLHTML is the abbreviat

Strona 60 - Port Menu

GlossaryGlossary-5Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08MirroringMirroring allows you to mirror (copy) the bi-directional

Strona 61 - Service Menu

GlossaryGlossary-6Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Power line 1/2Power supply line 1/2 of the OSM/ESM.Redundancy mana

Strona 62 - Web-Based Management (WBM)

GlossaryGlossary-7Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Signaling contactBinary contact used with SIMATIC NET network comp

Strona 63 - 4.1 General Introduction

GlossaryGlossary-8Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Static addressStatic address stored in the OSM/ESM FDB table (non-

Strona 64 - 4.2 Requirements

GlossaryGlossary-9Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08TrapIf certain events occur, the OSM/ESM can generate (SNMP) trap

Strona 65 - 4.3 Connecting

Index-11Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08AAddress type, 4-40Administrator, 3-2Agent , 1-2Aging, 2-6, 4-37Aging time,

Strona 66 - Figure 4-2 “Login” Window

Index-12Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Port pool, 4-44Power line 1 , 4-19Power line 2, 4-19Power monitoring, 4-21Pr

Strona 67 - Figure 4-3 WBM Startup Window

Introduction1-4Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08100 Mbps100 Mbps. . . RM100 Mbps10MbpsAccess by the management statio

Strona 68

Introduction1-5Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-081.2 Network Management for Industrial NetworksThe trend towards large

Strona 69 - Data Window

Introduction1-6Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-081.2.3 Web-Based Management (WBM)To allow users to introduce network m

Strona 70 - 4.6 Management Menus

Introduction1-7Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08100 Mbps. . .Applet of theaddressedcomponent (in the exampleOSM)Netwo

Strona 71 - 4.7 System

2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Classification of Safety-Related NoticesThis manual contains notices which you shou

Strona 72 - 4.7.1 System Version Numbers

Introduction1-8Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-081.3 Command Interpreter (CLI)In addition to the Web-Based Management,

Strona 73 - MAC Address

2-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Important OSM/ESM Functions2

Strona 74 - 4.7.2 System Restart

Important OSM/ESM Functions2-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.1 AutonegotiationIn the autonegotiation mode, an ele

Strona 75 - (restoring the defaults)

Important OSM/ESM Functions2-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.2 AutocrossoverElectrical OSM/ESM ports with the aut

Strona 76 - 4.7.4 System Save & Load

Important OSM/ESM Functions2-4Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.4 Factory Defaults and Protected SettingsDefaultsThe

Strona 77 - Firmware File

Important OSM/ESM Functions2-5Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.5 Filtering Database (FDB Table)The FDB (Filtering D

Strona 78 - 4.7.5 Event Log Table

Important OSM/ESM Functions2-6Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.5.2 Displaying and Deleting FDB Entries, AgingThe en

Strona 79 - 4.8 OSM/ESM Status

Important OSM/ESM Functions2-7Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08NoteThe OSM/ESM passes on all spanning tree frames reg

Strona 80 - Power Line 2

Important OSM/ESM Functions2-8Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.6 Locked PortsLockingLocking is used to make sure th

Strona 81 - Fault Status

Important OSM/ESM Functions2-9Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.7 MirroringMirroring for DiagnosticsMirroring allows

Strona 82 - 4.8.1 OSM/ESM Fault Mask

3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08TrademarksSIMATICR, SIMATIC HMIR and SIMATIC NETR are registered trademarks ofSIEME

Strona 83 - Set New Values

Important OSM/ESM Functions2-10Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.8 TrapsTrap MessagesIf certain events occur, the OS

Strona 84 - 4.8.2 OSM/ESM Standby Mask

Important OSM/ESM Functions2-11Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.9 E-Mail FunctionThe OSM/ESM has an E-mail function

Strona 85

Important OSM/ESM Functions2-12Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.10 Event Log TableEvents are entered chronologicall

Strona 86 - 4.8.3 OSM/ESM Counters

Important OSM/ESM Functions2-13Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.11 Time of Day and Time-of-day SynchronizationThe O

Strona 87

Important OSM/ESM Functions2-14Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.12 Flow ControlFlow control is a mechanism that red

Strona 88 - 4.9 Agent Features

Important OSM/ESM Functions2-15Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.13 BOOTP/DHCPIf there is a BOOTP or DHCP server in

Strona 89

Important OSM/ESM Functions2-16Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.14 IP Configuration Using SIMATIC NET NCM PC, SIMAT

Strona 90

Important OSM/ESM Functions2-17Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.15 TELNETWith TELNET, you can operate the CLI of th

Strona 91

Important OSM/ESM Functions2-18Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.16 Extended Redundant ConfigurationRedundant Coupli

Strona 92 - SMTP Server IP Address

Important OSM/ESM Functions2-19Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Extended Redundant Configuration with Network Managem

Strona 93 - “From” Field

4Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Prior to StartupBefore putting the product into operation, note the following:Cauti

Strona 94

Important OSM/ESM Functions2-20Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08In problem-free operation, only the standby ports of

Strona 95 - 4.9.5 Agent ARP Table

Important OSM/ESM Functions2-21Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.17 Observer FunctionThe observer function provides

Strona 96 - 4.9.6 Agent SNMP Counters

Important OSM/ESM Functions2-22Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Table 2-2 StatusMeaning Possible Cause Remedydisable

Strona 97 - 4.10 Switch Features

Important OSM/ESM Functions2-23Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-082.18 Automatic Download of the ConfigurationIf the fi

Strona 98 - Set New Value

3-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Command Interpreter (CLI)3

Strona 99 - 4.10.1 Current FDB Table

Command Interpreter (CLI)3-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-083.1 OverviewThe CLI is required for the following:S To s

Strona 100 - Next Values

Command Interpreter (CLI)3-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-083.3 Installing the CLIThe CLI is accessible via the seri

Strona 101 - 4.10.2 Static FDB Table

Command Interpreter (CLI)3-4Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-083.4 LoginOnce the connection has been established via th

Strona 102

Command Interpreter (CLI)3-5Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-083.5 CLI CommandsThis section explains the commands of th

Strona 103

Command Interpreter (CLI)3-6Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08ExampleThe following example illustrates how to use CLI

Strona 104

iIndustrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08PrefaceOSM/ESM with Network ManagementAs of firmware version 2.0, all Industrial Et

Strona 105 - Entering a Multicast Address

Command Interpreter (CLI)3-7Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Start MenuYou can display all the other menus from the s

Strona 106 - 4.11 Port Status

Command Interpreter (CLI)3-8Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08System MenuIn the System menu, you can make settings req

Strona 107 - Flow Ctrl

Command Interpreter (CLI)3-9Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Table 3-3 Settings in the System MenuCommand CommentDesc

Strona 108 - 4.11.1 Port Configuration

Command Interpreter (CLI)3-10Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08OSM/ESM MenuThis menu includes special OSM/ESM settings

Strona 109

Command Interpreter (CLI)3-11Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Table 3-4 Settings in the OSM Menu, continuedCommand Co

Strona 110 - 4.12 Statistics Counters

Command Interpreter (CLI)3-12Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Agent MenuThe agent menu includes settings required to

Strona 111 - 4.12.1 Packet Size

Command Interpreter (CLI)3-13Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Table 3-5 Settings in the Agent MenuCommand CommentDesc

Strona 112 - 4.12.2 Packet Type

Command Interpreter (CLI)3-14Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Table 3-5 Settings in the Agent MenuCommand CommentDesc

Strona 113 - 4.12.3 Packet Error

Command Interpreter (CLI)3-15Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Switch MenuIn the switch menu, you can make global sett

Strona 114 - SNMP and RMON

Command Interpreter (CLI)3-16Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Table 3-6 Settings in the Switch MenuCommand CommentDes

Strona 115 - 5.1 SNMP

PrefaceiiIndustrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08NoteTo use SNMP management, RMON and traps, you require a networkmanagement

Strona 116 - 5.2 RMON

Command Interpreter (CLI)3-17Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Port MenuIn this menu, you can make port-specific setti

Strona 117

Command Interpreter (CLI)3-18Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Table 3-7 Settings in the Port MenuCommand CommentDescr

Strona 118 - 6.1 General Introduction

4-1Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Web-Based Management (WBM)4

Strona 119 - Figure 6-1

Web-Based Management (WBM)4-2Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.1 General IntroductionThe OSM/ESM includes integrated

Strona 120 - Figure 6-3

Web-Based Management (WBM)4-3Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.2 RequirementsTo access an OSM/ESM using WBM, the fol

Strona 121 - Figure 6-4

Web-Based Management (WBM)4-4Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.3 ConnectingConnect the Internet browser station and

Strona 122 - Requirements

Web-Based Management (WBM)4-5Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.4 Access Using Web-Based ManagementYou can access the

Strona 123

Web-Based Management (WBM)4-6Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08NoteIf no new passwords have been assigned, the valid p

Strona 124 - Notes on Troubleshooting

Web-Based Management (WBM)4-7Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.5 User Interface of Web-Based ManagementThe dialogs o

Strona 125

Web-Based Management (WBM)4-8Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Device Status FieldThe displays in the device status fi

Strona 126

PrefaceiiiIndustrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Notes for the ReaderHow you use the manual depends on what you want to do.

Strona 127

Web-Based Management (WBM)4-9Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.6 Management MenusThe WBM of the OSM/ESM has the foll

Strona 128 - Internet Browser Settings

Web-Based Management (WBM)4-10Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.7 SystemClicking the System menu opens the window s

Strona 129

Web-Based Management (WBM)4-11Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08System NameThe domain name of the OSM/ESM can be enter

Strona 130 - Figure A-2 Trusted Sites

Web-Based Management (WBM)4-12Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08HardwareHardware version of the OSM/ESM.Order NumberOr

Strona 131

Web-Based Management (WBM)4-13Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.7.2 System RestartWith the System Restart window (Fi

Strona 132

Web-Based Management (WBM)4-14Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.7.3 System Factory Defaults(restoring the defaults)F

Strona 133

Web-Based Management (WBM)4-15Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.7.4 System Save & LoadIn the Save & Load win

Strona 134

Web-Based Management (WBM)4-16Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Log Table FileName of the log table file (maximum 32 c

Strona 135

Web-Based Management (WBM)4-17Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.7.5 Event Log TableThe event log table (Figure 4-10)

Strona 136

Web-Based Management (WBM)4-18Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.8 OSM/ESM StatusThe OSM/ESM Status window (Figure 4

Strona 137

PrefaceivIndustrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08AudienceThis manual is intended for persons with the qualifications require

Strona 138 - A.2 Netscape Communicator 6.2

Web-Based Management (WBM)4-19Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Standby StatusPassive:The OSM/ESM is passive; in other

Strona 139

Web-Based Management (WBM)4-20Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Fault StatusRedundant power line down:Link down on mon

Strona 140 - Serial Port of the OSM/ESM

Web-Based Management (WBM)4-21Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.8.1 OSM/ESM Fault MaskFigure 4-12 shows the Fault Ma

Strona 141

Web-Based Management (WBM)4-22Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Set New ValuesTo change the settings in the fault mask

Strona 142 - Figure B-1 Properties Tab

Web-Based Management (WBM)4-23Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.8.2 OSM/ESM Standby MaskClicking the Standby Mask me

Strona 143 - References

Web-Based Management (WBM)4-24Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08To modify the assignments in the standby mask, follow

Strona 144

Web-Based Management (WBM)4-25Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.8.3 OSM/ESM CountersFigure 4-14 shows the OSM/ESM Co

Strona 145 - Abbreviations/Acronyms

Web-Based Management (WBM)4-26Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08Maximum Delay of RM Test Packets (ms)This display is o

Strona 146

Web-Based Management (WBM)4-27Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.9 Agent FeaturesFigure 4-15 Agent WindowE-MailThis i

Strona 147

Web-Based Management (WBM)4-28Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08BOOTP/DHCPBOOTP/DHCP specifies whether BOOTP/DHCP is a

Strona 148 - Glossary

PrefacevIndustrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08CautionWe expressly point out that automation networks must be isolated from

Strona 149

Web-Based Management (WBM)4-29Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.9.1 Agent Event ConfigurationIn the Agent Event Conf

Strona 150

Web-Based Management (WBM)4-30Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.9.2 Digital Input Configuration (only OSMs/ESMs with

Strona 151

Web-Based Management (WBM)4-31Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.9.3 Agent E-Mail ConfigurationFigure 4-18 shows the

Strona 152

Web-Based Management (WBM)4-32Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08“From” FieldAddress of the sender of the E-mails. Depe

Strona 153

Web-Based Management (WBM)4-33Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.9.4 Agent Trap ConfigurationClicking the Trap Config

Strona 154

Web-Based Management (WBM)4-34Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.9.5 Agent ARP TableClicking the ARP Table menu opens

Strona 155

Web-Based Management (WBM)4-35Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.9.6 Agent SNMP CountersThe Agent SNMP Counters windo

Strona 156

Web-Based Management (WBM)4-36Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.10 Switch Features Figure 4-22 shows the Switch wind

Strona 157

Web-Based Management (WBM)4-37Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-08AgingOSMs/ESMs automatically learn the source addresse

Strona 158

Web-Based Management (WBM)4-38Industrial Ethernet OSM/ESM Network ManagementC79000-G8976-C137-084.10.1 Current FDB TableClicking the Current FDB Table

Komentarze do niniejszej Instrukcji

Brak uwag