Strona 1 - Published: August 2014

OSM Service Connection User's GuideHP Part Number: 527274-045Published: August 2014Edition: J06.03 and subsequent J-series RVUs and H06.03 and su

Strona 2

Firmware Update...117Get Logical Disk(s)...

Strona 3 - Contents

AttributesNone.ActionsCollect CLIM LogsThis action finds and collects CLIM logs, saving them to a subvolume location on the NonStopsystem specified th

Strona 4 - 4 Contents

• CLIM Smart Array Controller• CLIM NIC• CLIM InfiniBand HCA• CLIM SAS Firmware• CLIM SAS BIOS• CLIM FC Firmware• CLIM FC BIOS• SAS Disk Enclosure (bu

Strona 5 - Contents 5

NOTE: This location is the alternate SYSnn on which you installed the SUT containing thenew firmware to be used for the update.• The IP address of the

Strona 6 - 6 Contents

DIMM (CLIM)A subcomponent of the CLIM; details that vary according to CLIM type include:• For G2 and G5 CLIMs, there are eight DIMM slots that can be

Strona 7 - Contents 7

PhysicalA code that identifies the generation of the component. Hardware revision codes areused for tracking components.Hardware RevisionIdentifies th

Strona 8 - 8 Contents

Backup PathThe accessibility of the backup path.Example: Inactive, ActiveAccess StateThe location of the backup disk path SCSI controller.Example: PMF

Strona 9 - Contents 9

1. Locate and transfer the appropriate firmware source file to your server. Disk firmware versionsvary by manufacturer and model number. The correct v

Strona 10

NOTE: With OSM Low-Level Link T0633 AAQ and later, you can also save system configurationfiles on the system console. Those saved configurations are n

Strona 11 - Contents 11

Switch Process PairSwitches the primary and backup disk I/O processes.Switch to Backup PathSwitches processing from the primary to the backup path.Swi

Strona 12 - 12 Contents

The total size (in kilobytes) of disk storage space.Media SizeThe number of the partition on a partitioned disk.Partition NumberThe location of the ph

Strona 13 - Contents 13

Process Pair...123Actions...

Strona 14 - 14 Contents

Abort DiskTerminates operation of all paths for the disk. When the Abort action finishes, the paths are in aHard Down state. You must use the Reset Di

Strona 15 - Contents 15

Start Backup PathStarts the backup path to this disk drive. When the Start action completes, the backup path is inthe started State.Start DiskStarts a

Strona 16 - 16 Contents

AttributesDisk (Fibre Channel)Displayed in the Attributes tab and Attributes dialog box only if the value is somethingother than OK. ValuesService Sta

Strona 17 - Contents 17

The state of the primary I/O process.Values: Running, StoppedPrimary Execution StateThe process ID of the primary I/O process. If the state of the pri

Strona 18 - 18 Contents

Abort Primary PathTerminates operation of the primary path to the disk. When the Abort action finishes, the path isin a Hard Down state. You must use

Strona 19 - Contents 19

Responsive TestVerifies that the disk drive is installed and responding.Save as System Load ConfigurationSpecifies, within OSM, this disk as an altern

Strona 20 - 20 Contents

Stop Backup PathTerminates the backup path to the disk. When the Stop action finishes, the path is in a Down state.If the disk drive is currently in u

Strona 21 - Contents 21

ActionsFirmware UpdateUpdates the firmware running on the SAS disk drive.Get Logical Disk(s)Retrieves the names of the logical disks configured for th

Strona 22 - 22 Contents

E4SA (Ethernet 4 ServerNet Adapter)An adapter that connects the ServerNet connections inside a server to an Ethernet local areanetwork (LAN). The Ethe

Strona 23 - Contents 23

Enable ServerNet PortEnables the specified ServerNet router port on this CRU. Perform this action only as directed byOSM alarm repair actions.Paramete

Strona 24 - 24 Contents

Switch to Primary Path...129Test Verify...

Strona 25 - Contents 25

EnclosureThe Enclosure object is displayed in the OSM Service Connection (J-series only) to represent a HPBladeSystem c-Class Enclosure in an HP Integ

Strona 26 - 26 Contents

This represents the status of the c7000 enclosure, as seen by the OA.Possible Values: Unknown, Other, OK, Degraded, Stressed, Predictive Failure, Erro

Strona 27 - Contents 27

Delete the Power Source ConfigurationDeletes a previously configured Configured AC or UPS backup power source and sets the specifiedConfiguration attr

Strona 28 - 28 Contents

LogicalThe logical device number used by the operating system to identify the disk.Example: 7Logical Device NumberThe current state of the backup disk

Strona 29 - Contents 29

The state of the backup I/O process.Values: Running, StoppedBackup Execution StateThe process ID of the backup I/O process. If the state of the backup

Strona 30 - 30 Contents

Start VolumeStarts all paths for both the primary and mirror drives of this volume.Stop Backup PathTerminates operation of the backup path to the disk

Strona 31 - Contents 31

AttributesExternal DiskDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StatePhysi

Strona 32 - What's New in This Guide

Backup PathAn identification number assigned to the device when configured.SCSI IDA number (1 or 2) that identifies the backup SCSI controller that ma

Strona 33

action completes or is cancelled, the disk drive is not usable until you restore the file system byusing the SCF Alter Label command.The action prompt

Strona 34

Stop Primary PathTerminates the primary path to the disk. When the Stop action finishes, the path is in a Down state.If the disk drive is currently in

Strona 35

Firmware...134Actions...

Strona 36

Example: Fan (1.1.22)AttributesFanDisplayed in the Attributes tab and Attributes dialog box only if attention orservice is required. ValuesService Sta

Strona 37

PhysicalThe part number of the component that was assigned in manufacturing. Usepart numbers for identifying and ordering parts.NOTE: Not displayed fo

Strona 38

AttributesPhysicalIndicates whether or not the fan’s amber LED is lit. This state is determinedby the Set LED State action.Value: On or OffLED StateLo

Strona 39

AttributesNone.ActionsReplaceLaunches a documented service procedure to replace a fan in a SAS disk enclosure.Fan (VIO)A component of VIO enclosures (

Strona 40 - About This Guide

LogicalThe state of the FC Card as known to the operating system on the server.Possible values include: OK, Degraded, Fault, Power Off.Device StateThe

Strona 41 - Related Reading

PhysicalIndicates whether or not the FC-AL I/O Module’s (amber) fault LED is blinking.Value: Blinking or OffLED StateThe vendor hardware type.TypeLogi

Strona 42 - 1 Introducing OSM

AttributesFCDMDisplayed in the Attributes tab and Attributes dialog box only if the value is somethingother than OK. ValuesService StatePhysicalIdenti

Strona 43 - OSM Event Viewer

Path AThe location of FCSA connected to the disk drive through Port A.Example: FCSA.FSAC-1.GRP-111.MOD-2.SLOT-1Configured Controller LocationIdentifie

Strona 44 - Installing OSM Components

Verify Path B AccessVerifies that Path B from the FCDM via FC-AL I/O module B to the FCSA FSAC is responding.FCDM CollectionThe OSM Service Connection

Strona 45 - 3 Configuring OSM

OSM does not display FCSA attribute information until an associated disk process is configuredand started. For more information, see the Fibre Channel

Strona 46 - Configuring the Server

FCSA FSAC...142Actions...

Strona 47

ReplaceLaunches an interactive action to assist with replacement of an FCSA.Note: This replacement procedure is intended for authorized service provid

Strona 48

7. Grasp the FCSA by its handle while supporting the bottom edge of the FCSA with the otherhand and pull the FCSA the rest of the way out of the slot.

Strona 49 - Running Multiple Sessions

c. Firmly push the FCSA to the rear of its slot, but do not force it.CAUTION: To avoid damaging the connector pins, apply equal pressure to both theto

Strona 50

ActionsResponsive TestVerifies that the FCSA FSAC is present and responding. (To pass the test, a disk using this FSACmust be configured and started.)

Strona 51 - 5 Using the Management Window

StartStarts the Fast Ethernet ServerNet adapter (FESA) and the associated Ethernet ServerNet addressablecontroller (SAC). The FESA and the SAC must be

Strona 52 - OSM Menu Bar Options

The name of the fibre channel port that connects the router to the FCSA.World Wide Port NameThe part number of the component that was assigned in manu

Strona 53 - Tools Menu

AttributesFSACDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StatePhysicalThe tr

Strona 54 - Rediscover Shortcut Menu Item

PhysicalA code that identifies the generation of the component. Hardware revisioncodes are used for tracking components.Hardware RevisionThe part numb

Strona 55 - Using the Physical View

or, in a VIO enclosure:System > Fabric Group 100 > Internal ServerNet Fabric > VIO Module > G4SA > G4SA SAC >G4SA PIFExample: G4SA P

Strona 56 - Using the Inventory View

StartStarts the G4SA PIF. The PIF must be in the Stopped state before you perform this action. Whenthe Start action completes, the PIF is in the Start

Strona 58 - Interpreting Icons and Color

The processor to which the G4SA SAC is connected.Owning ProcessorThe currently available processors that can access the resource.Example: 0,1,4,8,9Pro

Strona 59 - Alarm Severity

The Gigabit Ethernet ServerNet Adapter (GESA) CRU contains one Gigabit Ethernet ServerNetaddressable controller (SAC), which contains one Ethernet phy

Strona 60

Group (IOMF2 or VIO)This type of group object contains either a legacy Nonstop S-series IOMF2 enclosure or, forNS16000CG or NS5000 only, VIO Modules u

Strona 61 - 6 Viewing Alarms

Group (IOAM, Fabric, G16SE)Depending on system type and configuration, this Group object may be displayed in OSM torepresent:• IOAM Group• Fabric Grou

Strona 62 - Viewing Alarm Details

Hard Disk (CLIM)A subcomponent of the CLIM. For G2 and G5 CLIMs, there is only one hard disk object, locatedin Bay 1. For G6 and Gen8 CLIMs, there are

Strona 63 - Deleting Alarms

LogicalThe state of the InfiniBand HCA card as known to the operating system onthe server. Possible values include: OK and Fault.Device StateA text st

Strona 64 - 7 Viewing Attributes

Example: Internal ServerNet Y FabricAttributesNone.ActionsGroup Connectivity ServerNet Path TestYou can perform this action on either the Internal Ser

Strona 65 - Suppression Persistence

IOAMs are initially configured using the Configure Module action in the OSM Low-Level Link, asdescribed in the NonStop NS-Series Hardware Installation

Strona 66 - 8 Performing Actions

AttributesIOAM EnclosureDisplayed in the Attributes tab and Attributes dialog box only if the value is somethingother than OK. ValuesService StatePhys

Strona 67 - Default Roles

With T0682 H02 AAN and later, you can also use the Physical Configuration Tool to set the RackName and Rack Offset values in a consistent manner throu

Strona 68 - Performing an Action

Group Connectivity ServerNet Path Test...156Processor-to-Processor Connectivity

Strona 69 - Aborting an Action

The voltage of the Other Rail, which connects the IOMF2 CRU to the otherpower supply in the enclosure (to provide power in the event of a problemwith

Strona 70 - Saving a Multi-Resource View

ReplaceLaunches the Replace IOMF guided procedure, which provides step-by-step instructions for replacingthe IOMF2 CRU.Storage ASIC Initialization Tes

Strona 71 - Performing Firmware Updates

Logical ProcessorThe OSM Service Connection displays Logical Processor objects for both HP Integrity NonStopBladeSystems (J-series software) and Integ

Strona 72 - Launching Guided Procedures

Valid only for NonStop BladeSystems, this attribute maps the Logical Processorto the Processor Blade it represents.Processor BladeIndicates whether th

Strona 73 - Configuration Tool

Enable Processor FreezeTurns the Freeze Enable flag on this processor on. If the OSM Low-Level Link System Freeze attributeis set to Enabled, a freeze

Strona 74 - 9 Viewing Summary Reports

Maintenance PICLocated in slot 1 of a processor switch in NonStop NS-series servers that contain processor switches.AttributesPhysicalA code that iden

Strona 75 - Viewing a Resource Summary

The version of the firmware running on the switch.Firmware RevisionThe IPv4 address of the switch.IPv4 AddressLists the port numbers of ports on the s

Strona 76 - 10 Managing a System

AttributesMemory CardDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StatePhysica

Strona 77 - 11 System Resources

Location action. This attribute is displayed only if a value is specied throughthe action.Temperature SensorThe current temperature, in degrees Celsiu

Strona 78

error in the system. By default, systems are configured with one SAP located in the CIA forthe group 11 I/O enclosure. You might need to set the Alarm

Strona 79 - Alarm Panel (Telco)

Disable Processor Freeze...163Enable Processor Freeze...

Strona 80 - ATM3SA (ATM Adapter)

AttributesNone.ActionsReplaceLaunches a documented service procedure to replace a CLIM motherboard.NIC (CLIM)A subcomponent of the CLIM.For Gen8 CLIMs

Strona 81 - Firmware Update

ReplaceLaunches a documented service procedure to replace a NIC in a CLIM.Optical Extender PICThese (optional) Optical Extender PICs are used only in

Strona 82 - ATM Line

ActionsPower OffShuts off power to the Optical Extender PIC.Power OnRestores power to the Optical Extender PIC.ReplaceLaunches a service procedure des

Strona 83

LogicalA unique number used to distinguish between plug-in cards on an MSEBCRU.Connector NumberActionsClear Loopback TestClears the loopback test on a

Strona 84 - Blade Complex

NOTE: This test fails if no device is attached to the PIC even if nothing is wrong with the PICitself.PIFPhysical interface (PIF) objects are the port

Strona 85 - Blade Element

Values: Last Open Successful, No Open Attempted, Bad Parameter, LobeFailed, Signal Loss, Insertion Timeout, Ring Failure, Beaconing, DuplicateMAC, Req

Strona 86

Temperature SensorThe minimum acceptable air intake temperature is 5 degrees Celsius. If thetemperature falls below 5 degrees, an alarm is generated.N

Strona 87 - Clear Forward Progress Log

ActionsReplaceLaunches an interactive action to guide you through replacement of a power supply CRU. Thisaction is applicable for IOMF2 and most PMF e

Strona 88 - 88 System Resources

• Handle with care -- the power supply weighs approximately 5.6 kilograms (14 pounds).• Follow these standard operating practices when replacing CRUs:

Strona 89 - Blade Element 89

3. Lower the ejector on the power supply to its fully open position. This action disconnects thepower supply from the power interface board (PIB) and

Strona 90 - Blade Element Firmware

Actions...170Firmware Update..

Strona 91 - ISP1040 Firmware

Installing the Replacement Power Supply1. Lower the ejector on the replacement power supply to its fully open position.2. With one hand, grasp the han

Strona 92 - Blower (FCDM)

PhysicalThe state of the Blade Element Power Supply, as known to the operatingsystem on the server. Possible values include OK, Fault, Power Loss, and

Strona 93

AttributesPower SupplyDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StatePhysic

Strona 94

PhysicalA code that identifies the generation of the component. Hardware revisioncodes are used for tracking components.Hardware RevisionThe part numb

Strona 95

Delete the Power Source ConfigurationSets the Configuration > Power Supply attribute value to Not Configured. You must be logged onas super.super t

Strona 96

powerfail-delay time interval specified for your UPS. For more information on preparing for ACpower-fail scenarios, see the NonStop NS16000 Series Pla

Strona 97

AttributesVIO Power SupplyDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StatePh

Strona 98

NOTE: This action is not valid for a power supply unit in an S-series VIO Module.Delete the Power Source ConfigurationSets the Configuration > Powe

Strona 99 - CLIMs 99

AttributesProcessor BladeDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StatePhy

Strona 100 - Attributes

NOTE: With T0682 AAN and later, OSM saves a copy of each Blade Element's BMC event logto a file in $system.zservice and clears the BMC event log

Strona 101 - CLIMs 101

Attributes...180Power Supply...

Strona 102 - CLIM-Attached Disks

Displayed only if a PE reintegration is in progress, this attribute displays theprogress in terms of percentage complete.NOTE: Displayed for NonStop N

Strona 103 - DIMM (CLIM)

LSU Optics AdapterNOTE: These attributes are displayed for NonStop NS14000 series and NS16000 series serversonly.A code that identifies the generation

Strona 104 - Disk Pair

Set LED StateSets these LSU LEDs to On or Off:• Optics adapter amber LED• Logic Board amber LED• ServerNet X Link LED• ServerNet Y Link LED• Serial ZX

Strona 105

Each processor switch module contains these components:• A ServerNet switch board, located in slot 14• Two power supplies, located in slots 15 and 18•

Strona 106 - 106 System Resources

refers to the running of OSM incident analysis, which checks EMS event messages and createsalarms in OSM if certain conditions exist.ReplaceLaunches a

Strona 107 - Disk 107

Slot Location: SACs are located on the CRUs that might be installed in slots 53 and 54 in processorenclosures (service side) or in slots 51, 52, 53, a

Strona 108 - Disk (CLIM-Attached)

FirmwareThe version of the boot firmware for the SAC.VersionThe name of the file to be used for a (boot) Firmware Update.Default File NameThe version

Strona 109 - Abort Backup Path

LogicalA list of the SAS Disk Enclosure(s) to which the SAS card is attached.Connected EnclosuresBIOSIndication of the differences, if any, between th

Strona 110 - 110 System Resources

AttributesSAS Disk EnclosureDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService State

Strona 111 - Disk (Fibre Channel)

The version of the firmware to be used for a firmware update.Default File VersionThe version of the firmware running on the SAS disk enclosure.Version

Strona 112

© Copyright 2014 Hewlett-Packard Development Company, L.P.Legal NoticeConfidential computer software. Valid license from HP required for possession, u

Strona 113

Actions...186Configure Power S

Strona 114 - 114 System Resources

The remaining IDs are for the device on the SCSI bus.The bus to which the device is attached:Bus 1 or 2: Internal deviceSCSI Bus NumberBus 3: External

Strona 115 - Disk (Fibre Channel) 115

AttributesServerNet Interface CardDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService

Strona 116 - Disk (SAS)

ActionsEnable ServerNet PortEnables the specified ServerNet port on this PIC. Perform this action only as directed by OSMalarm repair actions. Each PI

Strona 117 - DVD-ROM (Blade Element)

AttributesLogicalValues include: QSFP, POP4, SFP, Snap12Connector TypeDisplays the status of this port.Values: Disabled, Neighbor Check In Progress, E

Strona 118

ME FPGAThe VPROC of the ME FPGA (Field Programmable Gate Array) imagecurrently loaded on the switch.VersionThe full path name of the default ME FPGA f

Strona 119

Soft ResetReinitializes the firmware without affecting the ServerNet Switch hardware or the routing tables.Synchronize FIR Files to Other SwitchesSync

Strona 120 - Enclosure

LogicalThe date and time of the last hard or soft reset of the ServerNet Switch Board.Time of Last ResetThis attribute is displayed only within the Mu

Strona 121 - Configuration

ME Firmware UpdateAllows you to update the firmware file for the Maintenance Entity (ME) of the ServerNet SwitchBoard.Power CyclePower cycles the Serv

Strona 122 - ESS Disk

Indicates whether this service processor is the master service processor onthe system:Indicates whether this service processor is the master service p

Strona 123

ActionsResetCauses the service processor (SP) to reload the service processor operating image from the FLASHPROM.If the CLCI and CNSL (console) sessio

Strona 124

Write LCD Line...194SAC (ServerNet Addressabl

Strona 125 - External Disk

The version of the firmware to be used for a Smart Array Controller firmwareupdate.Default File VersionThe version of the Smart Array Controller firmw

Strona 126

Storage ASIC Initialization TestPrompts the storage subsystem manager process ($ZZSTO) to initialize the storage ASIC in theCRU. If initialization fai

Strona 127

SCSI ExtenderA pair of SCSI extenders (one SCSI-to-Fiber extender and one Fiber-to-SCSI extender) can be usedto increase the distance between the host

Strona 128 - 128 System Resources

Process PairThe 2 processors in which this I/O process is configured to run.Example: 0,1Configured ProcessorsThe state of the primary I/O process.Valu

Strona 129 - External Disk Collection

Example: SWAN2 $ZZWAN.#SWAN2AttributesSWAN $ZZWANDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK

Strona 130 - Fan Assembly (Blade Element)

Primary Host ConnectionIf the primary path of this SWAN concentrator is connected to a CLIM, thisattribute is the name of the primary CLIM. If the pri

Strona 131 - Fan (IOAM)

Location in OSM Tree: System > SWAN Collection > BatteryExample: Battery $ZZWAN.#SWAN2.BATAttributesBattery $ZZWANDisplayed in the Attributes ta

Strona 132 - Fan (SAS Disk Enclosure)

PhysicalThe Physical attributes are displayed for SWAN 2 CLIPs only.The part number of the component that was assigned in manufacturing. Usepart numbe

Strona 133 - FC Card (CLIM)

Test Primary Path AccessTests two-way access to the communications line interface processor (CLIP) using the primaryaddressTest VerifyRuns the power-o

Strona 134 - FC-AL I/O Module

AttributesLAN LB $ZZWANDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StatePhysi

Strona 135

Physical...201Actions...

Strona 136

Example: $ZZWAN.#D08XE5.1.DLC0The state of the data link control (DLC) task associated with the line as knownto the operating system.Values: Starting,

Strona 137

Verify Logical ConfigurationVerifies that the SWAN Path is properly configured. If not, an Incorrect Logical Configuration alarmis generated on the SW

Strona 138 - FCDM Collection

LogicalThe maximum processor configuration for the service processor. ValuesCurrent TopologyDisplayed only for NonStop BladeSystems, this attribute wi

Strona 139

Connection). You can specify up to four such alternate system disks; eachone is displayed in the system attributes (under a separate System LoadConfig

Strona 140 - Removing the FCSA

Collect Diagnostic DataThis action collects diagnostic data for your system. Upon performing the action, you are promptedto specify date and time para

Strona 141 - FCSA 141

Two attributes under the Logical attributes heading on the System object, Power RegulatorManagement Supported and Power Regulator Management Status, i

Strona 142 - FCSA FSAC

NOTE: The list of system types or configurations for which this action must be performed maygrow as other hardware and/or memory configurations requir

Strona 143

After clicking "Yes" to three confirmation dialog boxes and OSM reports that the action hascompleted successfully, check the OSM event viewe

Strona 144 - Fibre Channel Router

For more information, see Insight Remote Support Advanced for NonStop, located in the Supportand Service collection of NTL.Unsuppress Problem Incident

Strona 145 - Stop Monitoring

ActionsNone.TapeSpecifies a tape drive configured for a system.All tape drives are displayed under the Tape Collection object, whether they are attach

Strona 146

Processor Boot Millicode Firmware...208Actions...

Strona 147 - G4SA PIF

PhysicalThe part number of the component that was assigned in manufacturing. Usepart numbers for identifying and ordering parts. This is not the spare

Strona 148

CLIM PathThe CLIM to which the tape drive is configured.Configured CLIMIndicates the slot and port location for the HBA controller (either SAS or FC).

Strona 149 - G4SA SAC

Test VerifyRuns the power-on self-test for the tape drive. Additionally, runs tests to isolate problems involvingthe tape drive, SAC, or Common Base B

Strona 150

StopRather than automatically stopping the TRSA (as the Abort action does), this action first warns youif the TRSA is currently in use (and stops it o

Strona 151

Displays the version of the UPS software.Software VersionDisplays the physical location of the UPS as set by the super-user in the Link to WebInterfac

Strona 152 - Group (IOMF2 or VIO)

PhysicalA code that identifies the generation of the component. Hardware revisioncodes are used for tracking components.Hardware RevisionThe part numb

Strona 153 - Group (IOAM, Fabric, G16SE)

VIO G4SAIn an Integrity NonStop NS-series system containing VIO enclosures (represented in the OSMService Connection as VIO modules), OSM displays a G

Strona 154 - InfiniBand HCA Card (CLIM)

ActionsAbortTerminates operation of the VIO G4SA and the associated Ethernet ServerNet addressable controller(SAC). When the Abort action finishes, th

Strona 155 - Internal ServerNet Fabric

PhysicalA code that identifies the generation of the component. Hardware revisioncodes are used for tracking components.Hardware RevisionIndicates whe

Strona 156 - IOAM (I/O Adapter Module)

Hard ResetResets the VIO logic board hardware and the routing tables.ME FPGA UpdateAllows you to update the FPGA code file for the integrated maintena

Strona 157 - IOAM Enclosure

SWAN CLIP...216Attributes...

Strona 158

For more information, see the G16SE Service Provider Supplement for Integrity NonStopBladeSystems.Each VIO Module object, depending on the type of sys

Strona 159 - IOMF2 (I/O Multifunction 2)

PhysicalA code that identifies the generation of the component. Hardware revisioncodes are used for tracking components.Hardware RevisionThe part numb

Strona 160

With T0682 H02 AAN and later, you can also use the Physical Configuration Tool to set the RackName and Rack Offset values in a consistent manner throu

Strona 161

Compare State (Other)MeaningValueCurrent and default versions are the same.SameThe current version is newer than the default version.Up-revThe current

Strona 162 - Logical Processor

Group TypeA unique number in the system that identifies this group. Group Type is displayed in a window onthe front door of the enclosure.Depending on

Strona 163 - Disable Processor Freeze

MeaningPowered OnThere is a problem with the backup power supply for this component (as determined bythe Redundant Power Scrub action).Redundant Power

Strona 164 - 164 System Resources

SystemTypeS70000NSR-GS72000NSR-TS74000NSR-VS76000NSR-XS78000NSR-HS86000NSR-YS88000NSR-ZIntegrity NonStop NS16000 serverNSE-AIntegrity NonStop BladeSys

Strona 165 - Maintenance Switch

Tape TypesMeaningProduct ID9840 cartridge tape drive mounted in an L700 tape libraryCT9840-19840 cartridge tape drive mounted in a 9710 tape libraryCT

Strona 166 - Memory Card (Blade Element)

MeaningProduct IDSuper DLT tabletop with ACLT5258ACLSTK 9490 cartridge driveT9490Virtual Tape Solution: Tributary Systems Inc. 2UVT5801Virtual Tape So

Strona 167

12 Managing a ServerNet ClusterA ServerNet cluster is a collection of NonStop servers connected together using the ServerNetprotocol. There are two ge

Strona 168 - Set Physical Location

Operating System...222Data Collection Services...

Strona 169 - Motherboard (CLIM)

In the View drop-down list, you can select different views of the ServerNet cluster:• The Physical view depicts the connections and resources within t

Strona 170 - NIC (CLIM)

• Updating firmware and configuration for the 6770 cluster switch. Perform the Firmware Updateand Configuration Update actions on the ServerNet II swi

Strona 171 - Optical Extender PIC

Updating ServerNet II Switch ConfigurationNOTE: You can change the configuration tag as part of the Update Configuration action. However,you normally

Strona 172 - PCI Riser

PortInternal RouterPortExternal Slot55273111Layer7427137248211281284383491113922933944Router Connections for Router Interconnect PICsPortInternal Rout

Strona 173 - Internal Loopback Test

13 Cluster ResourcesA ServerNet cluster is built using one of several topologies. The resource objects displayed in theOSM Service Connection for a cl

Strona 174

AttributesSwitch ModuleDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StateLogic

Strona 175

Midplane PhysicalWhether the primary power source is On or Off.Primary AC Power StateWhether the backup power source is On or Off.Backup AC Power Stat

Strona 176 - Power Supply

Responsive TestTests the connectivity of the switch module from the local node.Set LocatorAllows you to enter text to aid in locating or identifying t

Strona 177 - Power Supply 177

AttributesBladeClusterDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StateBladeC

Strona 178 - Removing the Power Supply

ServerNet Path Test on Y FabricRuns a path test on the Y fabric, checking the local node's connection to the BladeCluster by testingthe Y fabric

Strona 179 - Power Supply 179

Test Verify...232TRSA (Token Ring Serve

Strona 180 - Power Supply (Blade Element)

AttributesLogicalThe Expand node number of the local node.Expand Node NumberValue: 0 through 254The Expand name of the local node.Node NameThe positio

Strona 181 - Power Supply (FCDM)

Y Fabric Connection #2Identifies the Y2 port used for BladeCluster connectivity.Port NameX Fabric Connection #1Identifies the X1 port used for BladeCl

Strona 182 - Power Supply (IOAM)

Whether the switch is configured for operation on the X fabric or the Y fabric.Values: X, Y, or ClearFabric SettingVerification that the switch is ins

Strona 183 - Configure Power Source as UPS

The state of the backup SANMAN process.Values: Running, StoppedBackup Execution StateThe process ID of the backup SANMAN process. If the state of the

Strona 184

ServerNet Local NodeThis object represents the system within a ServerNet cluster to which you are currently logged on.Location in OSM tree: Under the

Strona 185 - Power Supply (VIO)

LogicalThe state of the connection from the local node to the remote node over theexternal ServerNet Y fabric.Up: At least one of the processors on th

Strona 186

AttributesSwitchDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StateLogicalA uni

Strona 187 - Processor Blade

SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK NONEBlink LED OnCauses the LED to start blinking.SCF Equivalent: SCF ALTER SWITCH $ZZ

Strona 188

AttributesDisplayed in the Attributes tab and Attributes dialog box only if the value issomething other than OK. ValuesService StatePhysicalThe state

Strona 189 - Processor Components

ActionsNone.Switch Logic BoardA circuit board that provides switching logic for the 6780 switch. The logic board connects to apanel on the front of th

Strona 190 - LSU Logic Board

ME FPGA...238ME Firmware...

Strona 191

ConfigurationA parameter used by SCF and the guided procedures that allows SANMANto select an appropriate switch configuration block (SCB) from the sw

Strona 192 - Processor Switch Module

FPGA UpdateLoads an FPGA code file from the local node to the switch logic board. For details, see the ServerNetCluster 6780 Planning and Installation

Strona 193

LogicalThe initial state of the component at the time of discovery.Enabled: The component is operational.Enabled StateDisabled: The component is prese

Strona 194 - Write LCD Line

Disabled: The component is present but not operational.Whether the power supply has a fault.Values: OK, FaultDevice StateActionsBlink LED OffTurns off

Strona 195

ActionsNode Responsive TestTests the connectivity on the external ServerNet fabric through this port.Switch Node PortOn the 6780 switch, an external t

Strona 196 - SAS Card (CLIM)

The initial state of the component at the time of discovery.Values: OK, FaultTransceiver Device StateWhether the transceiver is enabled.Enabled: The c

Strona 197 - SAS Disk Enclosure

UnknownWhether the PIC is installed and responding.Values: Present, Absent, UnknownPresenceNeighbor Switch PICThe neighbor switch and PIC to which thi

Strona 198

Connected to nodeConnected to switch with wrong numeric selectorConnected to switch with invalid configuration version identifierConnected to wrong po

Strona 199 - SCSI Controller

LogicalThe percentage of charge remaining in the UPS batteries.Estimated Charge RemainingThe amount of time remaining (in minutes) that the UPS batter

Strona 200

OSM and Guided Procedures Display ValueSupported Configuration Tags*TopologyMax 16 nodes, nodes 1-8 (0x10000)0x10000Split-starMax 16 nodes, nodes 9-16

Strona 201 - ServerNet PIC

Actions...255Replace...

Strona 202 - ServerNet Port

14 Updating ServerNet Cluster TopologyYou can update a ServerNet cluster to support more nodes or to expand the geographical limitsof the cluster.Thes

Strona 203

These three methods are supported for updating to the split-star or tri-star topology:• Merging two star topologies to create a split-star topology• M

Strona 204

11. Use OSM to monitor the connectivity on the X fabric for all the nodes and switches. Connectivityon the X fabric should be restored over time. Conf

Strona 205 - ServerNet Switch Board

Cable Connections Between Star GroupsUpdating to the Split-Star TopologyIf you are updating to the split-star topology, connect the cables as follows:

Strona 206

PortPIC SlotConnect to SwitchPortPIC SlotSwitch411X12/Y12411X11/Y11112X13/Y13112X11/Y11212X13/Y13212X11/Y11312X13/Y13312X11/Y11412X13/Y13412X11/Y11113

Strona 207 - Service Processor (SP)

PortPIC SlotConnect to SwitchPortPIC SlotSwitch22X2412X1412X2422X1423X2413X1413X2423X14Y Fabric Connections Between Two ZonesThis table lists the Y-fa

Strona 208 - SCSI Boot Code Firmware

PortPIC SlotConnect to SwitchPortPIC SlotSwitch22X2312X1312X3322X1323X2313X1313X3323X1322X2412X1412X3422X1423X2413X1413X3423X1422X3112X2123X3113X2122X

Strona 209 - Smart Array Controller (CLIM)

PortPIC SlotConnect to SwitchPortPIC SlotSwitch23Y3113Y2122Y3212Y2223Y3213Y2222Y3312Y2323Y3313Y2322Y3412Y2423Y3413Y24Cable Connections in a Layered To

Strona 210 - SNDA (ServerNet/DA)

IndexSymbols4PSE, 78actions, 78attributes, 786770 Switch Moduleabout, 254actions, 255attributes, 2556780 Switch Moduleabout, 255actions, 256attributes

Strona 211 - Storage Router

CLIM-Attached Disks, 102CLIMs, 133CLIMs (container object), 99Clusterabout, 262actions, 263attributes, 262cluster of Key Managers,cluster resourceslis

Strona 212

Actions...262ServerNet Cluster

Strona 213 - SWAN / SWAN2

about, 138attributes, 138FCSAabout, 138actions, 139, 235attributes, 139, 234removing and installing, 140FCSA FSACabout, 142actions, 143attributes, 142

Strona 214

Logical Processor State, 162MMaintenance PICabout, 165actions, 165attributes, 165Maintenance Switchabout, 165actions, 166attributes, 165managing a sys

Strona 215 - SWAN Battery

Read Core License File, 226Rediscover System, 226Rediscover System and ServerNet Cluster, 226Redundancy State, 163Register CLIMs with Key Managers (gu

Strona 216 - SWAN CLIP

about, 219actions, 220attributes, 219SWAN Pathabout, 220actions, 220attributes, 220SWAN Power Supply see SWAN PSSWAN PSabout, 221actions, 221attribute

Strona 217

VIO Logic Boardabout, 237actions, 238attributes, 237VIO Moduleabout, 239actions, 241VIO Power Supplyactions, 186Wwindowprinting, 51XX Fabric Responsiv

Strona 218 - SWAN LAN Logic Board (LANLB)

15 Register CLIMs with Key Managers Guided ProcedureOnline HelpIntroductionThe Register CLIMs with Key Managers Guided Procedure guides you through th

Strona 219 - SWAN Line

All CLIMs to be registered must be selected and moved from the upper to the lower list using theAdd or Add All buttons (the Ctrl key can be used to se

Strona 220 - SWAN Path

You can define up to three tiers by providing the IPv4 addresses for Key Managers that are allmembers of the same Key Manager Cluster. At least two Ke

Strona 221 - SWAN (Power Supply)

Upon clicking the Check connectivity to all Key Managers button, the guided procedure checks theconnectivity by attempting to log on to each Key Manag

Strona 222 - System Load Configuration

In the top portion of the dialog box, the CLIM Client Group Name box displays the name("NonStop") of the CLIM group created by the guided pr

Strona 223

ContentsWhat's New in This Guide...32About This Guide...

Strona 224 - 224 System Resources

Actions...269Switch Logic Boar

Strona 225 - System 225

Using the Select the Local CA Dialog BoxNOTE: The Select Local CA dialog box is displayed twice during the guided procedure if youchoose to have your

Strona 226 - 226 System Resources

Click Continue to proceed to the next step of the guided procedure: Selecting Certification Methodand Creating Client Certificates.Selecting Certifica

Strona 227 - System 227

• Creating Client Certificate Automatically – having the guided procedure create a clientcertificate for each CLIM automatically.• Using your own X.50

Strona 228 - Tape Collection

Upon clicking Create CLIM Client Certificates, the guided procedure starts the process of creatingthe client certificates, including a private key and

Strona 229

• The certificate must be added to the Default Trusted CA List in one of the Key Managers. Forinformation on how to do this, see the NonStop Volume Le

Strona 230 - Controller Path

indicated by red italic text). You can correct the error and repeat the validity check, or go onto step 5 to complete the registration process for the

Strona 231

After each registration attempt, the success or failure for each CLIM is reported in the far left column(a green check mark indicates success, a red &

Strona 232

Neighbor Switch PIC...276Actions...

Strona 233 - Unknown CRU

What's New in This GuideDescribes features available with OSM Service Connection version T0682 H02 ADL, including:• Support/requirement for Java

Strona 234 - VIO FCSA

Also new for H06.27/J06.16, OSM Low-Level Link (T0633 G07 ABS) adds a “Select to changeiLO Admin user's password” option in the Configure CLIM di

Strona 235

• A new Place Local Node in Service action on the BladeCluster object, to be used whenintentionally halting a system to prevent all other directly-con

Strona 236 - VIO G4SA

• Support for disk partitioning on both Hard Disk Drives (HDDs) and Solid State Disks (SDDs),including:◦ The Start Disk, Start Volume, Stop Disk, and

Strona 237 - VIO Logic Board

At H06.20/J06.09, OSM Service Connection (T0682 H02 ACC) added support for:• NonStop Volume Level Encryption, which provides a simple and secure metho

Strona 238 - Dump Memory

At H06.19/J06.08, OSM Service Connection (T0682 H02 ABX) added:• New actions on the System object to Configure BladeCluster and Clear External Cluster

Strona 239 - VIO Module

to include support for J06.03 and the components, as displayed by the OSM Service Connection,of an HP Integrity NonStop BladeSystem, including:• HP Bl

Strona 240

At H06.07, the OSM Service Connection Suite was updated to T0682 H02 AAU to provide supportfor:• An improved module-level Redundant Power Scrub test.

Strona 241

State Indicators...58Alarm Indicators..

Strona 242 - Common Attribute Values

About This GuideThe OSM Service Connection User's Guide is available as online help within the OSM ServiceConnection, and in the NonStop Technica

Strona 243 - Enabled State

Related ReadingSources of OSM-related information:• This manual, the OSM Service Connection User's Guide, is available in the NonStop TechnicalLi

Strona 244 - Power State

1 Introducing OSMThe OSM client components are installed on a PC workstation that serves as the system console.The OSM server components are installed

Strona 245 - Processor Type

For ObjectOSM ActionOSM Guided ProcedureFCDM or subcomponent (Fibre Channeldisk drive, FC-AL I/O module, EMU,power supply, and blower)ReplaceReplace F

Strona 246 - Service State

2 Preparing the OSM EnvironmentTo plan your network LAN configuration and connect your system console so it can communicatewith your NonStop server th

Strona 247 - Tape Types

3 Configuring OSMBefore using OSM applications to manage your system.• Configure the server using the OSM Low-Level Link (see Configuring the Server).

Strona 248 - Topology

Configuring the ServerYou must configure these server components using the OSM Low-Level Link:ToUse this dialog boxConfigure unique MSP IP addresses f

Strona 249 - BladeCluster Solution

For rack-integrated UPS units, OSM provides an orderly system shutdown in the event that a powerfailure exceeds the powerfail-delay time interval spec

Strona 250 - Monitoring a Cluster

4 Starting the OSM Service ConnectionYou can:• Launch an OSM Service Connection• OSM Service Connection Session Error Messages• Using OSM Bookmarks• V

Strona 251 - Updating Cluster Switches

NOTE: When using Secure Sockets Layer (SSL) to establish a secure connection to theNonStop server, OSM checks that the server certificate that meets a

Strona 252

Physical...78Logical...

Strona 253

You cannot run multiple sessions by:• Reusing a browser window used for a previous OSM Service Connection session• Selecting File > New to open a n

Strona 254 - 13 Cluster Resources

5 Using the Management WindowThe OSM Management window appears after system discovery. It displays OSM features andinformation about your local system

Strona 255 - 6780 Switch Module

Management Window ExampleInternet Explorer Menu BarThe Internet Explorer menu bar is not customized for the OSM application. For most OSM functions,us

Strona 256

to a menu option under the Tools menu. This topic describes the options available under eachOSM menu.CAUTION: Do not close the Management window when

Strona 257 - BladeCluster

the Logical Status view. If the icon turns yellow, select this LogicalStatus menu option to locate the problem and get details.While the Logical Statu

Strona 258

refers to the running of OSM incident analysis, which checks EMS event messages and createsalarms in OSM if certain conditions exist.Using the Physica

Strona 259 - External ServerNet Fabric

To display the Physical view of an enclosure:1. In the tree or Overview pane, click a group.2. From the View list, select Physical.Physical View of a

Strona 260

The unique number assigned to every component. If you know a component's partnumber and tracking ID, you can find its exact location in the syste

Strona 261 - Remote 6770 Switch

Interpreting Icons and ColorThe OSM Service Connection uses different icons and colors to indicate a change from normalstatus in a group or resource i

Strona 262 - ServerNet Cluster

State icons are also shown in the Physical viewof a cluster or system.Alarm IndicatorsIf the object has at least one alarm, an alarm icon appears:In t

Strona 263

Attributes...86Blade Element...

Strona 264 - ServerNet Remote Node

A potential or impending service-affecting fault was detected before any significanteffects are evident. For example, retriable errors exceeded a thre

Strona 265 - ServerNet II Switch

6 Viewing AlarmsWhen certain problem conditions exist on a system, OSM generates alarms on the objects in needof service or attention.Alarms can be vi

Strona 266

Viewing the Alarms Dialog BoxTo reach this dialog box, either:• Right-click any object in the tree pane or view panes and select Alarms.• Highlight an

Strona 267 - Switch Fan

Click Save. In the Save As dialog box, specify a file name and folder and click Save. The informationis saved as a text file.To reach this dialog box:

Strona 268 - Switch Group

7 Viewing AttributesEvery resource has attributes associated with it. You can view the attributes of a resource in thedetails pane of the Management w

Strona 269 - Switch Logic Board

Select, then right-click a problem attribute in either the Attributes tab or Attributes dialog box andclick either Permanent or Temporary suppression,

Strona 270

8 Performing ActionsYou can perform and monitor actions as follows:• Perform a specific action on a selected resource: Performing Actions on a Selecte

Strona 271 - Switch PIC

Behavior for the threeDefault Rolesis as follows:• NonStop Super ID – No changes can be made to this default role, in terms of membership orprivileges

Strona 272 - Switch Power Supply

in this dialog box. You can add members to the new role by clicking Add Member. Under Privileges,select the actions that can be performed by the membe

Strona 273 - Switch-to-Node PIC

Viewing Detailed Information About an Action1. In the Action Status list, select the action whose details you want to view.2. Click Details to display

Strona 275 - Switch-to-Switch PIC

4. Select the specific resources on which to perform the action:ToSelectMove all resources in the available resources list to the selected resources l

Strona 276 - Switch Port

Viewing Action DetailsThe Action Detail box provides a description of a selected action, the resource acted upon, andthe action status. The detail als

Strona 277 - UPS (6770 Switch Module)

6. Click Perform Action.As the firmware update is performed, its status appears to the left of the resource name in theselected resources list.A summa

Strona 278

Monitored Service LAN Devices objects do not have a Set Physical Location action; however, theRack Name and Offset values can be set by placement of t

Strona 279 - Port Connectivity Status

9 Viewing Summary ReportsYou can view a:• Problem Summary• Summary of Actions• Summary of Alarms• Resource SummaryViewing a Problem SummaryThe Problem

Strona 280 - Updating Star Topologies

The Alarm Summary dialog box provides this information about each alarm:• Alarm severity• Time and date the alarm occurred• Resource name• Description

Strona 281 - Updating Star Topologies 281

10 Managing a SystemA system consists of all the hardware components, software, and firmware that are managed bya single operating system.Using the OS

Strona 282

11 System ResourcesUsing OSM, you can monitor and maintain these system resources:Processor BladeFESAAlarm PanelProcessor ComponentsFiber (Blade Switc

Strona 283

VIO FCSAPower Supply (IOAM)FC Card (CLIM)VIO G4SAPower Supply (Processor Switch)FC-AL I/O ModuleVIO Logic BoardPower Supply (SAS Disk Enclosure)FCDMVI

Strona 284

Set LED StateTurns on or off the amber LED located on the 4PSE. The current state is indicated by the LED Stateattribute.Alarm Panel (Telco)For Telco

Strona 285

Logical...104Process Pair...

Strona 286

ActionsLink to Web InterfaceOpens a Web interface that provides detailed device configuration and information for the alarmpanel.RediscoverCauses OSM

Strona 287

Indication of whether the ATM adapter software is automatically dumped to the specifieddump file if the software abends abnormally.Automatic Dump Stat

Strona 288 - 288 Index

Test VerifyRuns all the firmware diagnostic tests on the CRU. This test takes about three minutes to finish. TheCRU must be in the Stopped state befor

Strona 289

BatteryThe battery customer-replaceable unit (CRU), located in Nonstop S-series processor or I/Oenclosures, is an assembly of 24 cells rated at 2.5 am

Strona 290 - 290 Index

Total Voltage SensorThe minimum voltage that the battery should maintain is 42 volts.If the battery's Total Voltage falls below 42 volts, an alar

Strona 291

The expected redundancy for all the processors in the complex. Set usingthe Set Processor Expected Redundancy action.Values: Simplex, Duplex, TriplexE

Strona 292 - 292 Index

• Two Blade Element Power Supply objects.• Fan Assembly objects to represent each fan in the Blade as follows: slots 16 through 19 forNS1000, slots 16

Strona 293

The version of the Disk Boot firmware currently running on the processorBlade Element.NOTE: Not applicable for NonStop NS14000 series and NS16000 seri

Strona 294 - 294 Index

Enable Blade Element ReintegrationAvailable for NonStop NS14000 series and NS16000 series servers only, this action enablesautomatic reintegration of

Strona 295 - Online Help

Retrieve Forward Progress LogRetrieves the Forward Progress Log (FPL), which is more detailed than the System Event Log.NOTE: This action can take up

Strona 296

Start Primary Path...111Start Volume...

Strona 297

following Reset, and perform the Reset to start running the new (non-BMC) firmware. Then you canupdate the other image, which was the Running image bu

Strona 298

Primitive State FirmwareThe version of the Primitive State firmware currently running on the processorBlade Element.Running VersionThe version of the

Strona 299

The difference, if any, between the current Running image and default BMCfirmware version. ValuesRunning Compare StateThe difference, if any, between

Strona 300

Location in OSM Tree: System > Group > FCDM Collection > FCDM > BlowerExample: Blower (111.211.1.97)AttributesBlowerDisplayed in the Attri

Strona 301

PhysicalA code that identifies the generation of the component. Hardware revision codes areused for tracking components.Hardware RevisionIdentifies th

Strona 302

• FC Card• Hard Disk• InfiniBand HCA Card (G6 CLIMs only)• Motherboard (G6 and Gen8 CLIMs only)• NIC• PCI Riser• Power Supply• Processor• SAS Card• Se

Strona 303

This attribute applies only to supported storage CLIMs (G5 and later), andindicates whether or not – at the time of discovery – the CLIM had beenRegis

Strona 304

The IPv4 address of the Integrated Lights Out (iLO) port on the CLIM. The IPaddress of the CLIM iLO is displayed only when SNMP is available; however,

Strona 305 - Registering CLIMs

The version of the firmware to be used for an iLO firmware update.Default File VersionThe version of the firmware running on the iLO.VersionROMVersion

Strona 306

Replace Hard DriveLaunches a guided procedure to make replacement of a CLIM hard disk drive more automated.This guided procedure can also be launched