Primary Host Connection
If the primary path of this SWAN concentrator is connected to a CLIM, this
attribute is the name of the primary CLIM. If the primary path of this SWAN
Host Connection Point
concentrator is connected to a PIF, this attribute is the location of the SLSA
adapter containing the primary PIF.
Format:$ZZCIP.CLIM_Name, (Group, Module, Slot)
Example:$ZZCIP.C1002581, (110, 2, 4)
If the primary path of this SWAN concentrator is connected to a CLIM, this
attribute is the name of the Ethernet interface in the primary CLIM to which
Host Interface
the SWAN concentrator is connected. If the primary path of this SWAN
concentrator is connected to a PIF, this attribute is the name of the LIF
corresponding to the primary PIF to which the SWAN concentrator is
connected.
Format:CLIM_Name.Interface_Name, LIF $ZZLAN.LIF_Name
Example:C1002581.eth2, LIF $ZZLAN.LANA
Alternate Host Connection
If the alternate path of this SWAN concentrator is connected to a CLIM, this
attribute is the name of the alternate CLIM. If the alternate path of this SWAN
Host Connection Point
concentrator is connected to a PIF, this attribute is the location of the SLSA
adapter containing the alternate PIF.
Format:$ZZCIP.CLIM_Name, (Group, Module, Slot)
Example:$ZZCIP.C1002582, (110, 2, 4)
If the alternate path of this SWAN concentrator is connected to a CLIM, this
attribute is the name of the Ethernet interface in the alternate CLIM to which
Host Interface
the SWAN concentrator is connected. If the alternate path of this SWAN
concentrator is connected to a PIF, this attribute is the name of the LIF
corresponding to the alternate PIF to which the SWAN concentrator is
connected.
Format:CLIM_Name.Interface_Name, LIF $ZZLAN.LIF_Name
Example:C1002582.eth2, LIF $ZZLAN.LANB
Actions
Start
Starts the SWAN concentrator and its associated CLIPs. When the Start action completes, the
SWAN concentrator and its associated CLIPs are in the Started state.
In a multisystem configuration, this action also causes the current system to take control of the
associated CLIPs. If any of the CLIPs are currently controlled by another system, that system loses
control of those CLIPs.
Stop
Terminates operation of the SWAN concentrator and all associated SWAN CLIPs. When the Stop
action completes, the SWAN CRU and associated SWAN CLIPs are in the Stopped state.
Verify Logical Configuration
Verifies that the SWAN Concentrator CRU is properly configured. If not, an Incorrect Logical
Configuration alarm is generated on the CRU.
SWAN Battery
A subcomponent of the SWAN 2 CRU that provides backup power for 30 seconds in the event of
a power outage.
SWAN Battery 215
Komentarze do niniejszej Instrukcji