Distributed Use of SIMATIC FS600 Laser
Scanner in Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 10/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
Parameter set for the laser scanner SIMATIC FS600
The parameter set for the laser scanner SIMATIC FS600 contains the
configuration data for the safety functional example. How to load the
configuration data into the laser scanner SIMATIC FS600 is described in
chapter
4.3. The parameter set for the laser scanner SIMATIC FS600
includes zone pair 1 (detection zone 1, warning zone 1) and zone pair 2
(detection zone 2, warning zone 2). The picture below shows a screenshot
from the LS4soft configuration and diagnostics software. You see the two
zone pairs.
Note
The contours of the protection and warning zones used in the safety
functional example are rectangles. The LS4soft configuration and
diagnostics software also enables parameterizing other contours (e.g.
semi circles) as zone delimiters.