Distributed Use of SIMATIC FS600 Laser Scanner in
Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 22/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
Note
The cable outlet of the PC adapter at the laser scanner SIMATIC FS600
must face towards the direction of the detection zone. The PC adapter
should only be connected in the installation phase or for control
purposes.
4.3 LS4soft configuration and diagnostics software
The example below shows how to load the following file containing the
parameter set into the laser scanner SIMATIC FS600.
• as_fe_i_010_v10_code_plscanner.ls
This file is available as download to the safety functional example (as the
associated STEP 7 project)
No. Action Note
1
Install the LS4soft configuration and diagnostics software
on your PG/PC.
2 Switch the laser scanner SIMATIC FS600 on.
3 Start LS4soft.
4
Connect the COM interface of your PG/PC with the laser
scanner SIMATIC FS600 using the PC adapter.
The configuration data
currently located on the laser
scanner SIMATIC FS600 are
being loaded.
5
Log on as “Authorized User“ and enter the required
password. Ls4sig
A query that no individual
password has been specified
appears.
Confirm the dialog box.
6
Wait until the laser scanner SIMATIC FS600 has
determined all status information.
The “Determining status
information from scanner”
window closes automatically.
7 Click “Close” in the “Scanner status information” window.