Introduction
System architecture
Automation systems
I/O modules
Input and output devices
Bus communication
Coupling with other systems
Appendix
AS 235, AS 235 H and
AS 235 K
Automation Systems
TELEPERM M
Catalog PLT 111 · 1999
REG. NO. 2613-04
The products and systems
described in this catalog are
marketed under application of
the quality management system
certified by DQS in accordance
with DIN EN ISO 9001 (certificate
register No.: 2613-04). The
DQS certificate is recognized in all
EQ Net countries (Reg. No.: 2613).
This catalog is no longer available in printed
form. However, it can still be used to obtain
information and for ordering spare parts.
Certain products from this catalog are no
longer available. Your Siemens partner will
offer appropriate substitutes wherever
possible.
Przeglądanie stron 0
1 2 3 4 5 6 ... 89 90

Podsumowanie treści

Strona 1 - TELEPERM M

sIntroductionSystem architecture Automation systems I/O modulesInput and output devicesBus communication Coupling with other systemsAppendixAS 235, AS

Strona 2

Siemens PLT 111 · 19992/4System architectureRedundancy with AS 235 HRedundancy with the AS 235 H automation systemVarious system characteristics must

Strona 3

Siemens PLT 111 · 19992/5System architectureConfiguringStandard function blocksStandard function blocksDedicated function blocks are present in the au

Strona 4

Siemens PLT 111 · 19992/6System architectureStandard function blocksConfiguringBlocks for processing withstandardized operation and monitoringType Des

Strona 5

Siemens PLT 111 · 19992/7System architectureConfiguringStandard function blocksDriver blocks for I/O modulesType Designation Function For modules with

Strona 6

Siemens PLT 111 · 19992/8System architectureStandard function blocksConfiguringDriver blocks for configurable TELEPERM ME I/O modulesDriver blocks for

Strona 7

Siemens PLT 111 · 19992/9System architectureConfiguringStandard function blocksOutput blocks for printer and process monitorOrganization blocksType De

Strona 8

Siemens PLT 111 · 19992/1 2/2 Performance characteristics2/4 Redundancy with AS 235 HConfiguring2/5 Standard function blocks2/10 User function blocks

Strona 9

Siemens PLT 111 · 19992/2System architecturePerformance characteristicsSystem architecturePerformance characteristicsThe AS 235, AS 235 H and AS 235 K

Strona 10 - System architecture

Siemens PLT 111 · 19992/3System architecturePerformance characteristicsSTEP MIn addition to the function blocks for binary processing, the AS 235/235

Strona 11

Siemens PLT 111 · 19992/4System architectureRedundancy with AS 235 HRedundancy with the AS 235 H automation systemVarious system characteristics must

Strona 12

Siemens PLT 111 · 19991/2TELEPERM MBrief descriptionIntroductionTELEPERM MTELEPERM M process control systemThe TELEPERM M process control system provi

Strona 13

Siemens PLT 111 · 19992/5System architectureConfiguringStandard function blocksStandard function blocksDedicated function blocks are present in the au

Strona 14

Siemens PLT 111 · 19992/6System architectureStandard function blocksConfiguringBlocks for processing withstandardized operation and monitoringType Des

Strona 15

Siemens PLT 111 · 19992/7System architectureConfiguringStandard function blocksDriver blocks for I/O modulesType Designation Function For modules with

Strona 16 - Siemens PLT 111 · 1999

Siemens PLT 111 · 19992/8System architectureStandard function blocksConfiguringDriver blocks for configurable TELEPERM ME I/O modulesDriver blocks for

Strona 17

Siemens PLT 111 · 19992/9System architectureConfiguringStandard function blocksOutput blocks for printer and process monitorOrganization blocksType De

Strona 18

Siemens PLT 111 · 19993/1 Automationsystems3/2 GeneralAS 2353/3 Basic cabinet3/6 Ordering data for basic cabinet3/7 Options for basic cabinet3/8 Exte

Strona 19

Siemens PLT 111 · 19993/2Automation systemsGeneralAutomation sys temsGeneralThe AS 235 automation system is available in three different ver-sions:• A

Strona 20

Siemens PLT 111 · 19993/3Automation systemsAS 235Basic cabinetAS 235 automation systemThe AS 235 automation system is the cabinet version of the range

Strona 21

Siemens PLT 111 · 19993/4Automation systemsBasic cabinetAS 235Standard I/O devicesThe standard I/O devices such as process monitor, process operation

Strona 22

Siemens PLT 111 · 19993/5Automation systemsAS 235Basic cabinetWhen ordering the extension units it is possible to select whether the extension unit EE

Strona 23

Siemens PLT 111 · 19991/3TELEPERM MIntroductionBrief descriptionFunctions of the AS 235 systemThe AS 235, AS 235 H and AS 235 K automation systems pro

Strona 24

Siemens PLT 111 · 19993/6Automation systemsOrdering data for basic cabinetAS 235With the standard ordering configuration, an additional connec-tion un

Strona 25 - Automation

Siemens PLT 111 · 19993/7Automation systemsAS 235Options for basic cabinetOrdering data Order No.Options for AS 235 basiccabinet Basic unitBackup batt

Strona 26 - Automation systems

Siemens PLT 111 · 19993/8Automation systemsExtension cabinetAS 235Extension cabinetDepending on the complexity of the automation task, the capac-ity o

Strona 27

Siemens PLT 111 · 19993/9Automation systemsAS 235 HBasic cabinetAS 235 H automation systemThe AS 235 H automation system is the high-availability cabi

Strona 28

Siemens PLT 111 · 19993/10Automation systemsBasic cabinetAS 235 HThe memory module with Error Detection and Correction EDC can correct a 1-bit error w

Strona 29

Siemens PLT 111 · 19993/11Automation systemsAS 235 HBasic cabinetStandard I/O devicesThe standard I/O devices such as process monitor, process operati

Strona 30

Siemens PLT 111 · 19993/12Automation systemsBasic cabinetAS 235 HRedundant process I/OsSome of the I/O modules are suitable for producing a redundant

Strona 31

Siemens PLT 111 · 19993/13Automation systemsAS 235 HBasic cabinetThe connection unit for a redundant AS 235 H basic unit com-prises:• 2 interface modu

Strona 32

Siemens PLT 111 · 19993/14Automation systemsOrdering data for basic cabinetAS 235 HOrdering dataAS 235 automation system,basic cabinet6DS2 131- - Basi

Strona 33

Siemens PLT 111 · 19993/15Automation systemsAS 235 HOptions for basic cabinetOrdering data Order No.Options for AS 235 H basiccabinet Basic unitRetrof

Strona 34

Siemens PLT 111 · 19991/4TELEPERM MSystem dataIntroductionGeneral system data1)Permissible ambient temperature• Modules– Operation– Δt/h– Δt/min– Tran

Strona 35

Siemens PLT 111 · 19993/16Automation systemsExtension cabinetAS 235 HOrdering data Order No.Options for AS 235 H basiccabinet (continued) Remote bus c

Strona 36

Siemens PLT 111 · 19993/17Automation systemsAS 235 HOrdering data for extension cabinetOrdering dataAS 235 H automationsystem,extension cabinet6DS2 13

Strona 37

Siemens PLT 111 · 19993/18Automation systemsBasic systemAS 235 KAS 235 K automation systemThe AS 235 K automation system is the compact version of the

Strona 38

Siemens PLT 111 · 19993/19Automation systemsAS 235 KBasic systemThe central processor divides the RAM and differentiates access operations to• the 1-M

Strona 39

Siemens PLT 111 · 19993/20Automation systemsOrdering data for AS 235 KAS 235 KMax. 2 interface modules N-V.24 inserted in one of the I/O slots in the

Strona 40

Siemens PLT 111 · 19993/21Automation systemsES 100 KES 100 K extension systemES 100 K extension systemUp to eight ES 100 K extension systems can be co

Strona 41

Siemens PLT 111 · 19993/22Automation systemsOrdering data for ES 100 KES 100 KHousingThe ES 100 K extension system is installed in a sheet-steel hous-

Strona 42

Siemens PLT 111 · 19993/23Automation systemsStandard cabinetsStandard cabinets and accessoriesStandard cabinets and accessoriesThe AS 235 and AS 235 H

Strona 43

Siemens PLT 111 · 19993/24Automation systemsOrdering data for system cabinet accessoriesStandard cabinetsOrdering data Order No.System cabinet accesso

Strona 44

Siemens PLT 111 · 19993/25Automation systemsStandard cabinetsPermissible thermal loadingPermissible thermal loading, configuring guidelinesStandard ca

Strona 45

Siemens PLT 111 · 19991/5TELEPERM MIntroductionSystem dataTechnical data of automation systemsCentral unitCentral processor MicroprogrammedArithmetic

Strona 46

Siemens PLT 111 · 19993/26Automation systemsStandard cabinets IP 20 without heat exchangerStandard cabinetsStandard cabinet with degree of protection

Strona 47

Siemens PLT 111 · 19993/27Automation systemsStandard cabinetsStandard cabinets IP 54 with heat exchangerStandard cabinets with degree of protection IP

Strona 48

Siemens PLT 111 · 19993/28Automation systemsProcess connection systemsProcess connection systemsProcess connection systemsProcess signal cables, infor

Strona 49

Siemens PLT 111 · 19993/29Automation systemsConnection diagramsStandard I/O devices to AS 235 / AS 235 KConnection diagrams for standard I/O devices t

Strona 50

Siemens PLT 111 · 19993/30Automation systemsConnection of personal computerConnection diagramsConnection of personal computerProcess monitor Process m

Strona 51

Siemens PLT 111 · 19993/31Automation systemsConnection diagramsConnection of process monitors andparallel monitorsConnection of process monitors and p

Strona 52

Siemens PLT 111 · 19993/32Automation systemsStandard I/O devices to AS 235 HConnection diagramsConnection diagrams for standard I/O devices to AS 235

Strona 53

Siemens PLT 111 · 19993/33Automation systemsConnection diagramsStandard I/O devices to AS 235 HProcess operationkeyboardProcess operationkeyboardConfi

Strona 54

Siemens PLT 111 · 19993/34Automation systemsSummary of connecting cablesConnection diagramsItem Connecting cableFromToPlug 1 Plug 2 Cable Max. cablele

Strona 55

Siemens PLT 111 · 19994/1 4/2 SummaryFunction modules4/5 Closed-loop control modules4/5 Calculation modulesSignal modules4/6 Analog input and output

Strona 56

Siemens PLT 111 · 19991/6TELEPERM MSystem dataIntroductionTechnical data of automation systems (continued)I/O modulesFunction modules/calculation mod-

Strona 57

Siemens PLT 111 · 19994/2I/O modulesSummaryI/O modulesSummaryThe I/O modules constitute the interface of the automation system to the process. I/O mod

Strona 58

Siemens PLT 111 · 19994/3I/O modulesSummaryConfigurable I/O modulesFunction modules generally have a configuration which is defined by their firmware

Strona 59

Siemens PLT 111 · 19994/4I/O modulesSummaryI/O modules from other systemsI/O modules from other systems can be operated on the I/O bus of an AS 235 au

Strona 60 - I/O modules

Siemens PLT 111 · 19994/5I/O modulesFunction modulesClosed-loop control modulesFunction modulesFunction modules have their own functions which are ind

Strona 61

Siemens PLT 111 · 19994/6I/O modulesAnalog input and output modulesSignal modulesSignal modulesAnalog input/output modules and binary input/output mod

Strona 62

Siemens PLT 111 · 19994/7I/O modulesSignal modulesBinary input and output modulesBinary input and output modulesThe following modules are available:•

Strona 63

Siemens PLT 111 · 19994/8I/O modulesProportioning counter module,metering pulse input moduleProportioning and counter modulesCounter modulesTwo counte

Strona 64

Siemens PLT 111 · 19994/9I/O modulesConfiguringModules which can be used on the I/O busModules which can be used on the I/O busThe following table doe

Strona 65

Siemens PLT 111 · 19994/10I/O modulesModules which can be used on the I/O busConfiguringDesignation Order No. ofmoduleRelease Re-marksAnalog calculati

Strona 66

Siemens PLT 111 · 19995/5Input and output devicesOperation unitPBT 65 process operation keyboardPBT 65 process operation keyboardThe PBT 65 process op

Strona 67

Siemens PLT 111 · 19992/1 2/2 Performance characteristics2/4 Redundancy with AS 235 HConfiguring2/5 Standard function blocks2/10 User function blocks

Strona 68

Siemens PLT 111 · 19995/8Input and output devicesConfiguring keyboardConfiguring unitConfiguring keyboardThe configuring keyboard is used to enter con

Strona 69 - Input and output devices

Siemens PLT 111 · 19995/9Input and output devicesConfiguring unitMini floppy disk unitMini floppy disk unitThe mini floppy disk unit is required for b

Strona 70

Siemens PLT 111 · 19996/1 6/2 Application6/2 Design6/5 Bus configurations6/6 Connecting cablesBuscommunicationThis catalog is out of date, see note o

Strona 71

Siemens PLT 111 · 19996/2Bus communicationApplicationBus communicationApplicationThe AS 235, AS 235 H and AS 235 K automation systems are connected to

Strona 72 - 6/2 Design

Siemens PLT 111 · 19996/3Bus communicationDesignIf e.g. automation systems are to be connected together via a local bus, the following are required fo

Strona 73 - Bus communication

Siemens PLT 111 · 19996/4Bus communicationDesignFig. 6/6 Connection of a redundant remote bus(AS 235 / AS 235 K/ AS 235 H)Redundant remote bus2 bus co

Strona 74

Siemens PLT 111 · 19996/5Bus communicationBus configurationsBus configurations, examplesApplication Other conditions Connecting cables20-m local busSm

Strona 75 - 1) Discontinued product

Siemens PLT 111 · 19996/6Bus communicationConnecting cablesConnecting cables for 20-m local busTo connect the interface modules for 20-m local bus to

Strona 76

Siemens PLT 111 · 19997/1 7/2 SummarySIMATIC S5expansion units7/3 Parallel coupling withS5-115U I/O modules7/5 Parallel coupling withS5-135U / 155U I

Strona 77

Siemens PLT 111 · 19997/2Coupling with other systemsSummaryCoupling with other systemsInterface modules for coupling with other systems,summarySummary

Strona 78 - Coupling with

Siemens PLT 111 · 19992/2System architecturePerformance characteristicsSystem architecturePerformance characteristicsThe AS 235, AS 235 H and AS 235 K

Strona 79 - Coupling with other systems

Siemens PLT 111 · 19997/3Coupling with other systemsSIMATIC S5 expansion unitsParallel coupling with S5-115U I/O modulesFig. 7/1 Coupling of automatio

Strona 80

Siemens PLT 111 · 19997/4Coupling with other systemsParallel coupling with S5-115U I/O modulesSIMATIC S5 expansion unitsSIMATIC S5-115U I/O modules ap

Strona 81

Siemens PLT 111 · 19997/5Coupling with other systemsSIMATIC S5 expansion unitsParallel coupling withS5-135U/155U I/O modulesFig. 7/2 Coupling of autom

Strona 82

Siemens PLT 111 · 19997/6Coupling with other systemsParallel coupling withS5-135U/155U I/O modulesSIMATIC S5 expansion unitsSIMATIC S5-135U/155U I/O m

Strona 83

Siemens PLT 111 · 19997/7Coupling with other systemsSIMATIC S5 expansion unitsInterface module for SIMATIC S5 expansion unitsInterface module for SIMA

Strona 84

Siemens PLT 111 · 19997/8Coupling with other systemsSerial couplingwith SIMATIC S5/S7 central controllersSIMATIC S5/S7 central controllersFig. 7/3 Cou

Strona 85

Siemens PLT 111 · 19997/9Coupling with other systemsSIMATIC S5/S7 central controllersInterface module forSIMATIC S5/S7 central controllersInterface mo

Strona 86

Siemens PLT 111 · 19997/10Coupling with other systemsSerial coupling with SIMATIC S5 I/OsSIMATIC S5 I/Os / ET 100UFig. 7/4 Coupling of automation syst

Strona 87

Siemens PLT 111 · 19997/11Coupling with other systemsSIMATIC S5 I/Os / ET 100USerial coupling with SIMATIC S5 I/OsET 100U I/O modules appropriate for

Strona 88

Siemens PLT 111 · 19997/12Coupling with other systemsInterface module for ET 100USIMATIC S5 I/Os / ET 100UInterface module for ET 100UThe interface mo

Strona 89

Siemens PLT 111 · 19992/3System architecturePerformance characteristicsSTEP MIn addition to the function blocks for binary processing, the AS 235/235

Strona 90 - Appendix

Siemens PLT 111 · 19998/2AppendixOrdering informationAppendixOrdering informationIndividual components/options and complete systemsWhen ordering, a di

Komentarze do niniejszej Instrukcji