Siemens SIMATIC TI505 Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Bramy / kontrolery Siemens SIMATIC TI505. Siemens SIMATIC TI505 User guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Ethernet Driver Help

Simatic / TI 505Ethernet Driver Help© 2015 Kepware Technologies

Strona 2 - Table of Contents

Simatic/TI 505 Ethernet Driver HelpEach device has now been defined under its own channel. Inthis new configuration, a single path of execution isdedi

Strona 3 - Overview

Simatic/TI 505 Ethernet Driver HelpData Types DescriptionData Type DescriptionBoolean Single bitWord Unsigned 16-bit valuebit 0 is the low bitbit 15 i

Strona 4 - Device Setup

Simatic/TI 505 Ethernet Driver HelpAddress DescriptionsAddress specifications vary depending on the model in use. Select a link from the following lis

Strona 5 - Communications Parameters

Simatic/TI 505 Ethernet Driver HelpV-Word MemoryBCD DecimalV<address>B 1-167772151-16777214Short, Word,BCDLong, DWord,FloatRead/WriteV-Word Memo

Strona 6 - CAMP vs. Packed Task Code

Simatic/TI 505 Ethernet Driver HelpDWord, FloatSystem StatusBit AccessSTW<address>.<bit>STW<address>:<bit>STW<address>,&

Strona 7 - Addressing Options

Simatic/TI 505 Ethernet Driver HelpThis type of string is a Standard String with LoHi byte order except the string length is always the maximumbecause

Strona 8

Simatic/TI 505 Ethernet Driver HelpNote: All 10 characters are displayed with the null-terminated string "hello" padded with 5 spaces to fil

Strona 9

Simatic/TI 505 Ethernet Driver Help0 = Status is good.1 = Base is not present or has a problem.Bit 1, Base 15Bit 2, Base 14Bit 3, Base 13Bit 4, Base 1

Strona 10

Simatic/TI 505 Ethernet Driver HelpBit 9-12, Seconds - Tens digitBit 13-16, Seconds - Units digitSTW144 Bit 1-4, Seconds - Tenths digitBit 5-8, Second

Strona 11 - Data Types Description

Simatic/TI 505 Ethernet Driver Help1 = Error or single power supplySTW00177-00183 Not used x x x xSTW00184 Module Mismatch IndicatorBit 1, 1 = Module

Strona 12 - Common Data Type Addressing

Simatic/TI 505 Ethernet Driver HelpTable of ContentsTable of Contents 2Simatic / TI 505 Ethernet Driver Help 3Overview 3Device Setup 4Cable Diagrams 5

Strona 13

Simatic/TI 505 Ethernet Driver HelpSTW213 Bit 1-16 slave addresses 48-33STW214 Bit 1-16 slave addresses 64-49STW215 Bit 1-16 slave addresses 80-65STW2

Strona 14 - String Support

Simatic/TI 505 Ethernet Driver HelpChecksumSTW00243 Reserved N/A N/A N/A xSTW00244 Additional Control Status FlagsBit 1, Controller Mode 0 = Program M

Strona 15

Simatic/TI 505 Ethernet Driver HelpNote: The actual number of addresses available for of each type depends on the PLC's configuration. If the dri

Strona 16 - Status Words

Simatic/TI 505 Ethernet Driver HelpAlarm MSW AlarmC FlagsACFH<address> 1-65536 Word Read/WriteAlarm LSW AlarmC FlagsACFL<address> 1-65536

Strona 17

Simatic/TI 505 Ethernet Driver HelpP 15/16, 0/1 Not used, set to 0*Elements A and B are write-only triggers. Writing 1 to the triggers sets the mode.

Strona 18

Simatic/TI 505 Ethernet Driver Helpe 30/31, 1/2 Contains SF program number (if an SF program is scheduled to be called)f 31/32, 0/1 Contains SF progra

Strona 19

Simatic/TI 505 Ethernet Driver HelpLoop Raw Setpoint LSPR<address> 1-65536 Word Read/WriteLoop Raw Error LERRR<address> 1-65536 Word Read

Strona 20

Simatic/TI 505 Ethernet Driver HelpElement LVF bit DescriptionA 0/1, 15/16 1=Go to manual mode*B 1/2, 14/15 1=Go to auto mode*C 2/3, 13/14 1=Go to cas

Strona 21 - Alarm Addressing

Simatic/TI 505 Ethernet Driver HelpL 11/12,20/211=Auto-mode lockM 12/13,19/201=Cascade-mode lockN 13/14,18/191=Setpoint lockO 14/15,17/180=Output scal

Strona 22

Simatic/TI 505 Ethernet Driver Help12/13E 4/5,11/121=Wait. This bit is set during a soak period when the PV is not within a specifieddeviation from th

Strona 23 - AVF Bit Definitions

Simatic/TI 505 Ethernet Driver HelpSimatic / TI 505 Ethernet Driver HelpHelp version 1.037CONTENTSOverviewWhat is the Simatic / TI 505 Ethernet Driver

Strona 24 - ACF Bit Definitions

Simatic/TI 505 Ethernet Driver Helpenough addresses are found to fill the output buffer. The search will cycle through all address types (C then X/Yfo

Strona 25 - Loop Addressing

Simatic/TI 505 Ethernet Driver HelpError DescriptionsThe following messages may be generated. Click on the link for a description of the message.Addre

Strona 26 - LVF Bit Definitions

Simatic/TI 505 Ethernet Driver HelpData type <type> is not valid for device address <address>.Error Type:WarningPossible Cause:A tag addre

Strona 27 - LCF Bit Definitions

Simatic/TI 505 Ethernet Driver HelpSolution:Check network connections.Device <device name> detected a Task Code error <error> (tag <add

Strona 28 - LRSF Bit Definitions

Simatic/TI 505 Ethernet Driver HelpPossible Cause:The device is unable to receive the amount of write data sent in one request.Note:This error is used

Strona 29 - Find Forced Addressing

Simatic/TI 505 Ethernet Driver HelpPossible Cause:The version number of the Winsock DLL found on the system is less than 1.1.Solution:Upgrade Winsock

Strona 30 - Output Formats

Simatic/TI 505 Ethernet Driver HelpTask Code Error CodesCode Description02 Address out of range (other than ladder logic).03 Requested data not found.

Strona 31

Simatic/TI 505 Ethernet Driver HelpIndex5505 Protocol 6AACF Bit Definitions 24Address <address> is out of range for the specified device or regi

Strona 32

Simatic/TI 505 Ethernet Driver HelpFFind Forced Addressing 29Float 11LLCF Bit Definitions 27Long 11Loop Addressing 25LRSF Bit Definitions 28LVF Bit De

Strona 33

Simatic/TI 505 Ethernet Driver HelpWWinsock initialization failed (OS Error = n). 34Winsock V1.1 or higher must be installed to use the Simatic/TI 505

Strona 34

Simatic/TI 505 Ethernet Driver HelpDevice SetupSupported DevicesCTI Interface CardsCTI 2572, CTI 2572-A, and CP2572 Ethernet interface cards on TI ser

Strona 35 - Solution:

Simatic/TI 505 Ethernet Driver HelpCable DiagramsCommunications Parameterswww. kepware.com5

Strona 36 - Task Code Error Codes

Simatic/TI 505 Ethernet Driver HelpDescriptions of the parameters are as follows:l Port Number: This parameter specifies the port number that the remo

Strona 37

Simatic/TI 505 Ethernet Driver HelpFor applications where the data can be divided into large blocks, using CAMP memory transfer will result in themost

Strona 38

Simatic/TI 505 Ethernet Driver HelpBit Order for V, K, WX, WY and STWThis option is used to select the order in which bits will be presented to V, K,

Strona 39

Simatic/TI 505 Ethernet Driver HelpOptimizing Simatic / TI 505 Ethernet CommunicationsThe Simatic / TI 505 Ethernet driver has been designed to provid

Komentarze do niniejszej Instrukcji

Brak uwag