11
Technical overviews
Controllers SPC4120 SPC5220 SPC5230 SPC6320 SPC6330
Hard-wired zones (max.)
8 to 32 8 to 128 8 to 512
Wireless zones (max.)
32 120 120
Programmable outputs (max.)
6 to 30 6 to 128 6 to 512
Number of areas (max.)
4 16 32
Number of doors (max.)
16 entry-exit/16 entry 32 entry-exit/64 entry
Number of users (max.)
32 256 512
Field bus
1 X-BUS interface (1 spur) 2 X-BUS interfaces (2 spurs or 1 loop) 2 X-BUS interfaces (2 spurs or 1 loop)
X-BUS devices (max.)
7
(3 expanders + 4 keypads)
48
(16 expanders + 16 keypads
+ 16 door expanders)
128
(64 expanders + 32 keypads
+ 32 door expanders)
Calendars
64 64
”Cause & Effect” programming
Yes Yes
Event memory
500 log events
10,000 intrusion and
10,000 access events
10,000 intrusion and
10,000 access events
Ethernet
On board
Embedded Web server
HTTPS HTTPS
Language
Single Multiple Multiple
Fast Programmer
Supported
Operating voltage
230 V AC, +10 to –15%, 50 Hz
Current consumption
Max. 100 mA (at 230 V AC) Max. 160 mA (at 230 V AC) Max. 200 mA (at 230 V AC)
Auxiliary power
1 output with max. 750 mA (at 12 V DC) on integrated PSU on controller PCB
Battery (optional)
Max. 7 Ah/12 V Max. 7 Ah/12 V Max. 17 Ah/12 V Max. 7 Ah/12 V Max. 17 Ah/12 V
Housing
Small metal enclosure
Small metal
enclosure
Hinged metal
enclosure
Small metal
enclosure
Hinged metal
enclosure
Security grade
EN 50131 Grade 2 EN 50131 Grade 2 EN 50131 Grade 3 EN 50131 Grade 2 EN 50131 Grade 3
Keypads SPCK420 SPCK421 SPCK422
Type
Wired LCD keypad Wired LCD keypad with card reader
Wired LCD keypad with integrated
wireless receiver
LCD display
2 x 16 characters
Card reader
125 kHz (EM4102 or compatible)
Frequency
868 MHz
Radio module
SiWay RF receiver
Operating voltage
9.5 – 14 VDC
Current consumption
Min. 55 mA (at 12 V DC)
Max. 90 mA (at 12 V DC)
Min. 90 mA (at 12 V DC)
Max. 110 mA (at 12 V DC)
Min. 65 mA (at 12 V DC)
Max. 95 mA (at 12 V DC)
Field bus
X-BUS on RS-485 (307 kb/s)
Housing
Plastic enclosure (ABS)
Security grade
EN 50131 Grades 2–3