TC65 Hardware Interface Description
Confidential / Released
s
TC65_HD_V02.000 Page 74 of 120 08.06.2006
3.18.2 Using the SYNC Pin to Control a Status LED
As an alternative to generating the synchronization signal, the SYNC pin can be configured
to drive a status LED that indicates different operating modes of the TC65 module. To take
advantage of this function the LED mode must be activated with the AT^SSYNC command
and the LED must be connected to the host application. The connected LED can be
operated in two different display modes (AT^SSYNC=1 or AT^SSYNC=2). For details please
refer to
[1].
Especially in the development and test phase of an application, system integrators are
advised to use the LED mode of the SYNC pin in order to evaluate their product design and
identify the source of errors.
To operate the LED a buffer, e.g. a transistor or gate,
must be included in your application. A sample circuit
is shown in
Figure 32. Power consumption in the LED
mode is the same as for the synchronization signal
mode. For details see
Table 26, SYNC pin.
Figure 32: LED Circuit (Example)