Assigning device parameters
5.3 Configuration settings of the device
Industrial Thin Client ITC1200, ITC1500, ITC1900, ITC2200
50 Operating Instructions, 04/2013, A5E03474888-02
5.3.5 Connections
5.3.5.1 Basics
Introduction
Users can connect from the Thin Client to different servers. Example:
RDP Server 1: Access to office planning documents
VNC Server 2: Access to Office spreadsheets
Sm@rtServer 3: Access to WinCC messages at the plant
SINUMERIK Server 4: Access to a SINUMERIK plant screen
Web Server 5: Access to web-based content, for example, of an S7 controller
(PROFINET) or Intranet/Internet using the integrated web browser.
Note
Web connection and web browser
You can configure a web connection, for example, the server address, in the Connection
setting
s (Page 54). You configure the web browser its
elf, for example, its proxy settings,
in the Application settings (Page 64).
You can establish up to 5 such client-server connections at the same time. These
connections are specified mainly by the following parameters:
Connection type, e.g., "Sm@rtServer" or "RDP"
IP address of the server
Port of the server
The Industrial Thin Client then displays the server screen as a full screen.
This section shows how you configure client-server connections. The connection settings
can be found in the configuration settings in the Start menu "Configuration > Connections".