Assigning device parameters
5.4 Remote configuration of several devices
Industrial Thin Client ITC1200, ITC1500, ITC1900, ITC2200
72 Operating Instructions, 04/2013, A5E03474888-02
Editing configuration settings of several devices synchronously
1. Select one or more devices in the device window
. The configuration window then
displays the following:
One device selected: the same configuration settings as on the device (see "Opening
the config
uration (Page 35)"). You navigate via the submenu on the left.
S
everal devices selected: configuration settings in a table. You navigate via the tree
view on the left. Only one setting group is expanded at a time: each row contains a
setting, and the columns contain the selected devices.
Click in one cell, to change this setting for one device.
No device selected: the Home page.
2. Change any settings in the individual cells, for example, the screen brightness.
3. To edit the IP addresses of the selected devices at the same time, switch to the "IP" tab
(see section "Assigning the IP address (Page 76)"). If you change or dynamically
assign IP addresses, observe the notes in the section "Network settings (Page 46)".
4. Touch the "Sav
e" button in the toolbar
. If there are IP address conflicts, an error
message appears. Otherwise, the modified configuration files are transferred to the
selected devices as if the changes were made locally on the device.
Copy button
If you touch the "Change entire line" button in the toolbar , the last change is transferred
to the entire row and is coped to all cells of the row.
Example: You change the value in the "Subnet mask" cell of device "x". The "Change entire
line" button transfers the new value to all cells of the line: the same subnet mask appears for
all selected devices.
Restriction: The "Change right line" button transfers the new value to all cells located to the
right of the modified cell. The cells located to the left remain unchanged.