Siemens DTU3005-B Instrukcja Operatora

Przeglądaj online lub pobierz Instrukcja Operatora dla Networking Siemens DTU3005-B. Siemens DTU3005-B Operator`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 141
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - DTU3005-B

DTU3005-BIntelligent Data Transfer Device for Connection to PLCs and Modbus NetworksOperator’s Manual

Strona 2

2 Installing the Software6 Siemens Energy & Automation, Inc.2 Installing the SoftwareThe DTU3005 Editor software can be installed fromthe DOS prom

Strona 3 - Table of Contents

Appendix E: Device Data Format96 Siemens Energy & Automation, Inc.Fault in the power system 49 ms since fault (-1 = no fault)General Trip for Fa

Strona 4

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 97Dist.: Fault detection phase L1,3,E 83 ms since fault (-1 = no occurance)Dist

Strona 5 - 1 Introduction

Appendix E: Device Data Format98 Siemens Energy & Automation, Inc.2 = Reset LEDs Unused3 = Activate Parameter Set A Unused4 = Activate Parameter

Strona 6

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 99E.13 Device Type: 7SA513Real-Time Device Data Stored in PLC (7SA513) Function

Strona 7

Appendix E: Device Data Format100 Siemens Energy & Automation, Inc.General Status Word 3216 Bit Contents15 AR: Auto-reclose is blocked (Valid)1

Strona 8

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 101Interrupted current:Phase L2 (I/In)27 ms since fault (-1 = no occurance)Inte

Strona 9

Appendix E: Device Data Format102 Siemens Energy & Automation, Inc.Trip by Breaker FailureProtection59 ms since fault (-1 = no occurance)Emerg.

Strona 10 - 2 Installing the Software

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 103Dist.: Time T3 (Zone Z3) expired 95 ms since fault (-1 = no occurance)Dist.:

Strona 11

Appendix E: Device Data Format104 Siemens Energy & Automation, Inc.5 = Activate Parameter Set C Unused6 = Activate Parameter Set D Unused10 = Ge

Strona 12 - 3 Starting the Software

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 105E.14 Device Type: 7SD511Real-Time Device Data Stored in PLC (7SD511) Functio

Strona 13

2 Installing the Software7 Siemens Energy & Automation, Inc.returns you to the DOS prompt as shown in theexample screen below.7. If you are runnin

Strona 14

Appendix E: Device Data Format106 Siemens Energy & Automation, Inc.Interrupted current:Phase L1 (I/In)15 High wordInterrupted current:Phase L2 (

Strona 15

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 107Emerg. O/C protection:Trip 3pole46 ms since fault (-1 = no occurance)General

Strona 16 - 4.1 Application Description

Appendix E: Device Data Format108 Siemens Energy & Automation, Inc.E.15 Device Type: 7SD512Real-Time Device Data Stored in PLC (7SD512) Function

Strona 17 - 4.3 PLC Setup—Port 1

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 109Fault Date/Time (y) 12 Year: YY (00…99)Interrupted current:Phase L1 (I/In)13

Strona 18

Appendix E: Device Data Format110 Siemens Energy & Automation, Inc.Emerg. O/C protection:Trip 1pole L244 ms since fault (-1 = no occurance)Emerg

Strona 19 - 4.4 Device Setup—Port 2

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 111E.16 Device Type: 7SJ511Real-Time Device Data Stored in PLC (7SJ511) Functio

Strona 20 - 4.5 Passthrough Setup—Port 3

Appendix E: Device Data Format112 Siemens Energy & Automation, Inc.General Status Word 3:217 Bit Contents14–15 Not Used13 Non-dir. ground O/C pr

Strona 21 - 4.6 Device List Setup

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 113O/C Fault Detection L1-L3 44 ms since fault (-1 = no occurance)O/C Fault Det

Strona 22

Appendix E: Device Data Format114 Siemens Energy & Automation, Inc.E.17 Device Type: 7SJ512Real-Time Device Data Stored in PLC (7SJ512) Function

Strona 23 - Registers

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 115General Status Word 3:215 Bit Contents15 Non-dir. ground O/C prot. is ACTIV

Strona 24

3 Starting the Software8 Siemens Energy & Automation, Inc.3 Starting the SoftwareTo start the DTU3005 Editor software, follow thesesteps:1. If you

Strona 25 - Registers by Device

Appendix E: Device Data Format116 Siemens Energy & Automation, Inc.General Status Word 6:218 Bit Contents14–15 Not Used13 59-Overvoltage protect

Strona 26

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 11751-Phase time element TRIP 45 ms since fault (-1 = no occurance)50NHS-Ground

Strona 27

Appendix E: Device Data Format118 Siemens Energy & Automation, Inc.E.18 Device Type: 7SJ531Real-Time Device Data Stored in PLC (7SJ531) Function

Strona 28

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 119General Status Word 3:218 Bit Contents15 Non-dir. phase O/C prot. is ACTIVE

Strona 29 - 4.9 Global Command Registers

Appendix E: Device Data Format120 Siemens Energy & Automation, Inc.General Status Word 6:221 Bit Contents15 DC-Q10 pos (Valid)14 DC-Q10 pos (Sta

Strona 30 - 4.11 Device Command Registers

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 121Interrupted current:Phase L3 (I/In)36 Low wordInterrupted current:Phase L3 (

Strona 31 - 4.12 Saving the Project File

Appendix E: Device Data Format122 Siemens Energy & Automation, Inc.O/C Fault Detection L2-E 73 ms since fault (-1 = no fault)O/C Fault Detection

Strona 32 - Master to Devices

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 123Device Command Data Retrieved From PLC (7SJ531)First Command Word (Command W

Strona 33

Appendix E: Device Data Format124 Siemens Energy & Automation, Inc.E.19 Device Type: 7SJ600Real-Time Device Data Stored in PLC (7SJ600) Function

Strona 34 - 5.3 Modbus Setup—Port 1

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 125General Status Word 4:210 Bit Contents2–15 Not Used1 Trip circuit supervisi

Strona 35 - Response Time-Out

3 Starting the SoftwareSiemens Energy & Automation, Inc. 93.2 Main MenuThe main menu is located on the top line of thescreen. In addition to th

Strona 36 - 5.4 Device Setup—Port 2

Appendix E: Device Data Format126 Siemens Energy & Automation, Inc.O/C protection I>> phase Trip 44 ms since fault (-1 = no occurance)O/C

Strona 37 - Modbus Master

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 127E.20 Device Type: 7UT512Real-Time Device Data Stored in PLC (7UT512) Functio

Strona 38 - Intermessage Time-Out

Appendix E: Device Data Format128 Siemens Energy & Automation, Inc.General Status Word 3:213 Bit Contents8–15 Not Used7 Differential protection

Strona 39 - 5.6 Device List Setup

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 129General Trip of Device 38 ms since fault (-1 = no occurance)Trip by thermal

Strona 40

Appendix E: Device Data Format130 Siemens Energy & Automation, Inc.E.21 Device Type: 7UT513Real-Time Device Data Stored in PLC (7UT513) Function

Strona 41

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 131General Status Word 3:213 Bit Contents12–15 Not Used11 Transformer tank pro

Strona 42

Appendix E: Device Data Format132 Siemens Energy & Automation, Inc.Restr. Curr. Of L3 at Trip(average DC)36 High wordRestr. Earth Flt.: Value D

Strona 43

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 133Device Command Data Retrieved From PLC (7UT513)First Command Word (Command W

Strona 44

Appendix F: Diagnostic Data Format134 Siemens Energy & Automation, Inc.F Diagnostic Data FormatWhen users select Diagnostic Information to be wr

Strona 45

Appendix G: WarrantySiemens Energy & Automation, Inc. 135GWarrantyICP PANEL-TEC, INC. warrants that all equipment pur-chased hereunder is warra

Strona 46

3 Starting the Software10 Siemens Energy & Automation, Inc.3. Type in a name for the project up to eight lettersand numbers in the Project Name: f

Strona 47 - 5.9 Global Command Registers

Appendix G: Warranty136 Siemens Energy & Automation, Inc.

Strona 48 - 5.12 Saving the Project File

Siemens Energy & Automation, Inc.Power Distribution Solutions3333 Old Milton ParkwayAlpharetta, GA 30005For Nearest Sales Office1.800.964.4114www.

Strona 49 - Port Expander

3 Starting the SoftwareSiemens Energy & Automation, Inc. 114. To select a project type, highlight the type andeither press Enter or click the l

Strona 50 - 6.1 Passthrough Setup—Port 1

4 Creating Project Files—PLC to Devices12 Siemens Energy & Automation, Inc.4 Creating Project Files—PLC to DevicesThis chapter covers configuratio

Strona 51

4 Creating Project Files—PLC to DevicesSiemens Energy & Automation, Inc. 13• Device Command Registers—allows you to indicatewhich PLC registers

Strona 52 - 6.3 Passthrough Setup—Port 3

4 Creating Project Files—PLC to Devices14 Siemens Energy & Automation, Inc.To select the PLC connected to port 1, highlight PLC Pro-tocol and pres

Strona 53 - 7 Transferring Project Files

4 Creating Project Files—PLC to DevicesSiemens Energy & Automation, Inc. 15program displays an entry box for the RTS delay time.Enter the time

Strona 54

SUMMARYThese instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in c

Strona 55

4 Creating Project Files—PLC to Devices16 Siemens Energy & Automation, Inc.Saving Port 2 Configuration InformationOnce you have entered all the co

Strona 56 - 8 Setting Options

4 Creating Project Files—PLC to DevicesSiemens Energy & Automation, Inc. 174.6 Device List SetupThe Device List menu item enables you to indica

Strona 57

4 Creating Project Files—PLC to Devices18 Siemens Energy & Automation, Inc.3. Select the device from the list by pressing Enter or thespacebar. Th

Strona 58

4 Creating Project Files—PLC to DevicesSiemens Energy & Automation, Inc. 196. Enter the beginning register number in the Real-TimeData Register

Strona 59

4 Creating Project Files—PLC to Devices20 Siemens Energy & Automation, Inc.4. Select a data register on the list and press Enter to seea list of a

Strona 60

4 Creating Project Files—PLC to DevicesSiemens Energy & Automation, Inc. 215. Select the data word (16 bit data) from the list andpress Enter.

Strona 61

4 Creating Project Files—PLC to Devices22 Siemens Energy & Automation, Inc.3. Select a data item and press Enter to see a list ofdevice real time

Strona 62 - Appendix A: Supported PLCs

4 Creating Project Files—PLC to DevicesSiemens Energy & Automation, Inc. 23To conserve registers when using VDEW devices, youshould set all unu

Strona 63

4 Creating Project Files—PLC to Devices24 Siemens Energy & Automation, Inc.The relevant status codes (Text #) are listed below.Table 4.1 7SJ600 Re

Strona 64

4 Creating Project Files—PLC to DevicesSiemens Energy & Automation, Inc. 25Once you are finished entering data, select Save to saveyour configu

Strona 65

Table of ContentsSiemens Energy & Automation, Inc. i1 Introduction ...11.1 Product Overview...

Strona 66 - Appendix B: Supported Devices

4 Creating Project Files—PLC to Devices26 Siemens Energy & Automation, Inc.parameter is used only with Allen-Bradley PLCs. Itspecifies the file nu

Strona 67 - C Installing the Hardware

4 Creating Project Files—PLC to DevicesSiemens Energy & Automation, Inc. 274. Enter the value for the Command Block Read Delay.This is the dela

Strona 68 - C.3 Connector Pinouts

5 Creating Project Files—Modbus Master to Devices28 Siemens Energy & Automation, Inc.5 Creating Project Files—Modbus Master to DevicesThis chapter

Strona 69 - D Cable Connection Diagrams

5 Creating Project Files—Modbus Master to DevicesSiemens Energy & Automation, Inc. 295.2 Configuring the Project FileOnce you have created or o

Strona 70 - DB-15 Male

5 Creating Project Files—Modbus Master to Devices30 Siemens Energy & Automation, Inc.5.3 Modbus Setup—Port 1You must have a Modbus Master to Devic

Strona 71 - Mini DIN

5 Creating Project Files—Modbus Master to DevicesSiemens Energy & Automation, Inc. 31Select either ASCII or RTU as your Modbus protocol,then pr

Strona 72 - Koyo 305

5 Creating Project Files—Modbus Master to Devices32 Siemens Energy & Automation, Inc.5.4 Device Setup—Port 2One or more Siemens devices may be con

Strona 73 - Mitsubishi

5 Creating Project Files—Modbus Master to DevicesSiemens Energy & Automation, Inc. 335.5 Modbus/Passthrough Setup—Port 3Port 3 can be used for

Strona 74 - DB-9 Male

5 Creating Project Files—Modbus Master to Devices34 Siemens Energy & Automation, Inc.Passthrough to Port 2 (SEAbus)If you select Passthrough to Po

Strona 75

5 Creating Project Files—Modbus Master to DevicesSiemens Energy & Automation, Inc. 355.6 Device List SetupThe device list menu item enables you

Strona 76

Table of Contentsii Siemens Energy & Automation, Inc.© Copyright 1999 Siemens Energy & Automation, Inc.SIEMENS is a registered trademark of Si

Strona 77

5 Creating Project Files—Modbus Master to Devices36 Siemens Energy & Automation, Inc.3. Select the device from the list by pressing Enteror the sp

Strona 78

5 Creating Project Files—Modbus Master to DevicesSiemens Energy & Automation, Inc. 37change the starting register to 10, the last registerwill

Strona 79

5 Creating Project Files—Modbus Master to Devices38 Siemens Energy & Automation, Inc.4. Select a data register on the list and press Enter tosee a

Strona 80 - T Series

5 Creating Project Files—Modbus Master to DevicesSiemens Energy & Automation, Inc. 395. Select the data word (16 bit data) from the list andpre

Strona 81 - EDevice Data Format

5 Creating Project Files—Modbus Master to Devices40 Siemens Energy & Automation, Inc.3. Select a data item and press Enter to see a list ofdevice

Strona 82 - –23 For Future Expansion

5 Creating Project Files—Modbus Master to DevicesSiemens Energy & Automation, Inc. 41To conserve registers when using VDEW devices, youshould s

Strona 83

5 Creating Project Files—Modbus Master to Devices42 Siemens Energy & Automation, Inc.The relevant status codes (Text #) are listed below.Table 5.1

Strona 84

5 Creating Project Files—Modbus Master to DevicesSiemens Energy & Automation, Inc. 43Once you are finished entering data, select Save tosave yo

Strona 85

5 Creating Project Files—Modbus Master to Devices44 Siemens Energy & Automation, Inc.register 40001, etc. Be sure that the registers youspecified

Strona 86

6 Creating Project Files—SEAbus Port ExpanderSiemens Energy & Automation, Inc. 456 Creating Project Files—SEAbus Port ExpanderThis chapter covers

Strona 87

1 IntroductionSiemens Energy & Automation, Inc. 11Introduction1.1 Product OverviewThe Panel-Tec DTU3005 is an intelligent, multiple-function data

Strona 88

6 Creating Project Files—SEAbus Port Expander46 Siemens Energy & Automation, Inc.6.1 Passthrough Setup—Port 1You must have a SEAbus Port Expander

Strona 89 - –25 For Future Expansion

6 Creating Project Files—SEAbus Port ExpanderSiemens Energy & Automation, Inc. 47When 2-wire communications are being used, RTSmust be looped bac

Strona 90 - Range or Contents

6 Creating Project Files—SEAbus Port Expander48 Siemens Energy & Automation, Inc.6.2 SEAbus Device Setup—Port 2One or more Siemens devices may be

Strona 91 - E.7 Device Type: SB-TL

7 Transferring Project FilesSiemens Energy & Automation, Inc. 497 Transferring Project FilesOnce you have configured and saved your project fil

Strona 92

7 Transferring Project Files50 Siemens Energy & Automation, Inc..Figure 7.1 Null Modem Cable connectionThe null modem cable will cross pins 2 an

Strona 93 - E.9 Device Type: ISGS

7 Transferring Project FilesSiemens Energy & Automation, Inc. 517.2 Uploading ProjectsSelect Upload project from DTU3005 from the Transfermenu,

Strona 94 - ISGS Operator’s Manual

8 Setting Options52 Siemens Energy & Automation, Inc.8 Setting OptionsThe Options menu allows you to configure settings forthe DTU3005 Editor so

Strona 95

8 Setting OptionsSiemens Energy & Automation, Inc. 532. The current directory path is shown in the Direc-tory Name field, and a graphical represe

Strona 96

8 Setting Options54 Siemens Energy & Automation, Inc.move up and down the directory tree. Press Enter,or select Ch Dir to see a list of all the

Strona 97 - E.11 Device Type: S7-I/O

8 Setting OptionsSiemens Energy & Automation, Inc. 552. To select the printer port, or to direct the printoutsto a file, use the Left and Right A

Strona 98 - E.12 Device Type: 7SA511

1 Introduction2 Siemens Energy & Automation, Inc.1.4.1 PLC to SEAbusThe basic configuration is a PLC attached to port 1 ofthe DTU3005, and the S

Strona 99

8 Setting Options56 Siemens Energy & Automation, Inc.2. If you have not previously saved your option set-tings, the following screen appears:3.

Strona 100

8 Setting OptionsSiemens Energy & Automation, Inc. 575. Select Ok to continue. The options settings willremain in effect the next time you run th

Strona 101

Appendix A: Supported PLCs58 Siemens Energy & Automation, Inc.ASupported PLCsApplication NotesA.1 Allen-Bradley PLC 5, SLC500 and MicroLogix PLCsR

Strona 102

Appendix A: Supported PLCsSiemens Energy & Automation, Inc. 59Note: The V-Memory word numbers in the abovetable are shown in octal. These numbers

Strona 103 - E.13 Device Type: 7SA513

Appendix A: Supported PLCs60 Siemens Energy & Automation, Inc.configured to do so by performing the following stepswhen configuring the PLC Port i

Strona 104

Appendix A: Supported PLCsSiemens Energy & Automation, Inc. 61p1 T0 0 (for PC COM Port 1)orp2 T0 0 (for PC COM Port 2)For example, if you are usi

Strona 105

Appendix B: Supported Devices62 Siemens Energy & Automation, Inc.BSupported DevicesThe following Siemens ACCESS devices are sup-ported by the DT

Strona 106

Appendix C: Installing the HardwareSiemens Energy & Automation, Inc. 63C Installing the HardwareThe DTU3005 device is a compact, low-power, sea

Strona 107

Appendix C: Installing the Hardware64 Siemens Energy & Automation, Inc.C.3 Connector PinoutsAll of the DTU3005B ports, 1 through 3, support both

Strona 108

Appendix D: Cable Connection DiagramsSiemens Energy & Automation, Inc. 65D Cable Connection DiagramsAllen Bradley PLC5Allen Bradley SLC5/03 &am

Strona 109 - E.14 Device Type: 7SD511

1 IntroductionSiemens Energy & Automation, Inc. 31.4.2 Modbus Master to SEAbusThe DTU3005 unit can be configured as a Modbus(RTU) slave. In this

Strona 110

Appendix D: Cable Connection Diagrams66 Siemens Energy & Automation, Inc.Allen Bradley MicrologixGE Fanuc 90/20, 30, 701142153164175186197208219

Strona 111

Appendix D: Cable Connection DiagramsSiemens Energy & Automation, Inc. 67Idec FA with Link AdapterIdec Micro-3111414221515331616441717551818661

Strona 112 - E.15 Device Type: 7SD512

Appendix D: Cable Connection Diagrams68 Siemens Energy & Automation, Inc.Koyo 205 (PLC Direct)Koyo 305 (PLC Direct)11421531641751861972082192210

Strona 113

Appendix D: Cable Connection DiagramsSiemens Energy & Automation, Inc. 69Koyo 405 (PLC Direct)Mitsubishi FX19210311 134612 14 15578114215316417

Strona 114

Appendix D: Cable Connection Diagrams70 Siemens Energy & Automation, Inc.Mitsubishi FXo/FXonModicon 984/Compact 98411421531641751861972082192210

Strona 115 - E.16 Device Type: 7SJ511

Appendix D: Cable Connection DiagramsSiemens Energy & Automation, Inc. 71Modicon Micro 984Omron 232 Host Link1142153164175186197208219221023112

Strona 116

Appendix D: Cable Connection Diagrams72 Siemens Energy & Automation, Inc.Omron C28HOmron CQM116273849511421531641751861972082192210231124122513D

Strona 117

Appendix D: Cable Connection DiagramsSiemens Energy & Automation, Inc. 73Siemens S7Simatic TI5 RS-232 Port1166227733884499551142153164175186197

Strona 118 - E.17 Device Type: 7SJ512

Appendix D: Cable Connection Diagrams74 Siemens Energy & Automation, Inc.Simatic TI5 RS-422 PortSquare D Model 100-700 PLC1627384951142153164175

Strona 119

Appendix D: Cable Connection DiagramsSiemens Energy & Automation, Inc. 75Square D TSX07Toshiba EX & M Series1142153164175186197208219221023

Strona 120

1 Introduction4 Siemens Energy & Automation, Inc.Figure 1.7 Connection to Modbus Master using a Multidrop CableMulti-Drop Modbus Master to SEAbu

Strona 121

Appendix D: Cable Connection Diagrams76 Siemens Energy & Automation, Inc.Toshiba T Series19210311 134612 14 155781142153164175186197208219221023

Strona 122 - E.18 Device Type: 7SJ531

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 77EDevice Data FormatThis appendix contains the real-time device data and comma

Strona 123

Appendix E: Device Data Format78 Siemens Energy & Automation, Inc.Control Parameters 18 Bit Contents7 Ground Fault Enable6 Service Factor (0 = 1

Strona 124

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 79E.2 Device Type: 4300 Power Meter Real-Time Device Data Stored in PLC (4300 P

Strona 125

Appendix E: Device Data Format80 Siemens Energy & Automation, Inc.E.3 Device Type: 4700 Power MeterReal-Time Device Data Stored in PLC (4700 Pow

Strona 126

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 81Device Command Data Retrieved From PLC (4700 Power Meter)First Command Word (

Strona 127

Appendix E: Device Data Format82 Siemens Energy & Automation, Inc.E.4 Device Type: 4720 Power MeterReal-Time Device Data Stored in PLC (4720 Pow

Strona 128 - E.19 Device Type: 7SJ600

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 83Device Command Data Retrieved From PLC (4720 Power Meter)First Command Word (

Strona 129

Appendix E: Device Data Format84 Siemens Energy & Automation, Inc.E.5 Device Type: Static Trip IIIReal-Time Device Data Stored in PLC (Static Tr

Strona 130

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 85Alarm Status 22 Bit Contents15 Overvoltage Setpoint14 Voltage Unbalance Setpo

Strona 131 - E.20 Device Type: 7UT512

1 IntroductionSiemens Energy & Automation, Inc. 51.4.3 SEAbus Port ExpanderThe DTU3005 can be used as a SEAbus port expanderfor ACCESS devices, a

Strona 132

Appendix E: Device Data Format86 Siemens Energy & Automation, Inc.E.6 Device Type: SensiTrip IIINote: No Commands from this device are supported

Strona 133

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 87E.7 Device Type: SB-TLNote: No Commands from this device are supported.Real-T

Strona 134 - E.21 Device Type: 7UT513

Appendix E: Device Data Format88 Siemens Energy & Automation, Inc.E.8 Device Type: Pulse Reading Meter (PRM)Real-Time Device Data Stored in PLC

Strona 135

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 89E.9 Device Type: ISGSReal-Time Device Data Stored in PLC (ISGS)Real-Time Data

Strona 136

Appendix E: Device Data Format90 Siemens Energy & Automation, Inc.Device Command Data Retrieved From PLC (ISGS Switchgear)First Command Word (Co

Strona 137

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 91E.10 Device Type: Sentron SB Energy Comm Trip UnitReal-Time Device Data Store

Strona 138 - F Diagnostic Data Format

Appendix E: Device Data Format92 Siemens Energy & Automation, Inc.Alarm Function StatusNote: When bit numbers arespecified, Bit 15 is thehighest

Strona 139 - Appendix G: Warranty

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 93E.11 Device Type: S7-I/OReal-Time Device Data Stored in PLC (S7-I/O) Function

Strona 140

Appendix E: Device Data Format94 Siemens Energy & Automation, Inc.E.12 Device Type: 7SA511Real-Time Device Data Stored in PLC (7SA511) Function

Strona 141

Appendix E: Device Data FormatSiemens Energy & Automation, Inc. 95General Status Word 3216 Bit Contents6–15 Not used5 Dist. teleprotection: Ca

Komentarze do niniejszej Instrukcji

Brak uwag