Siemens ET8 Series Instrukcje Operacyjne Strona 18

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 17
Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 18
5.1.2 Byte layout CLV61x Dual Port
The data storage area is set up in CDF600 mode as shown below:
The length of the data storage area is up to 128 bytes depending on the module selected.
Address
Inputs (Data CLV
PLC)
Output (Data PLC
CLV)
1
Binary status bits In
Binary Status Bits Out
2
ReceiveCount (counter)
ReceiveCountBack (counter)
3
TransmitCountBack (counter)
TransmitCount (counter)
4
ReceiveLength Lowbyte
TransmitLength Lowbyte
5
ReceiveLength Highbyte
TransmitLength Highbyte
6
ReceiveData, Byte 1
TransmitData, Byte 1
7
ReceiveData, Byte 2
TransmitData, Byte 2
n
ReceiveData, Byte n - 5
TransmitData, Byte n – 5
Przeglądanie stron 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 51 52

Komentarze do niniejszej Instrukcji

Brak uwag