SIMATIC S7-400
Central processing units
SIPLUS Y-Link for S7-400H
6/53
Siemens ST 70 · 2013
6
Overview
Bus coupler for transition from a redundant PROFIBUS DP
master system to a single-channel PROFIBUS DP master
system
For connection of devices with only one PROFIBUS DP
interface to the redundant PROFIBUS DP master system of the
SIMATIC S7-400H
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific infor-
mation was added.
For technical documentation on SIPLUS, see:
www.siemens.com/siplus-extreme
Ordering data
Order No. Order No.
SIPLUS Y-Link for S7-400H SIPLUS S7 BUS MODULE
BM Y coupler
Order No. 6AG1 197-1LA11-4XA0 6AG1 654-7HY00-7XA0
Order No. based on 6ES7 197-1LA11-0XA0 6ES7 654-7HY00-0XA0
Ambient temperature range 0 °C … +60 °C -25 °C … +70 °C
Conformal coating
Coating of the printed circuit boards and the electronic components
Technical data The technical data of the standard product applies except for the ambient conditions.
Ambient conditions
Relative humidity
100%, condensation/frost permissible. No commissioning if condensation present.
Biologically active substances,
compliance with EN 60721-3-3
Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused
interfaces during operation!
Chemically active substances,
compliance with EN 60721-3-3
Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must
remain in place over the unused interfaces during operation!
Mechanically active substances,
compliance with EN 60721-3-3
Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during opera-
tion!
Air pressure (depending on the
highest positive temperature range
specified)
1 080 ... 795 hPa (-1 000 ... +2 000 m) see ambient temperature range
795 ... 658 hPa (+2 000 ... +3 500 m) derating 10 K
658 ... 540 hPa (+3 500 ... +5 000 m) derating 20 K
For use with STEP 7 from V5.4 or
PCS 7 from V7.0:
SIPLUS Y-Link for S7-400H 6AG1 197-1LA11-4XA0
(medial exposure)
for connecting single-channel
DP slaves to SIMATIC S7-400H;
consisting of
2 IM 153 interface modules,
1 Y-coupler,
1 BM IM/IM bus module,
1 BM Y-coupler bus module
Accessories
SIPLUS S7 BUS MODULE
BM Y-coupler
6AG1 654-7HY00-7XA0
(extended temperature range and
medial exposure)
Additional accessories See SIMATIC Y-Link,