Page 78 SITRANS LU01 – INSTRUCTION MANUAL 7ML19985BE02
Parameters
Advanced Shot Adjustment (P840 to P852)
P840 Short Shot Number
The number of short shots to be fired (and results averaged) per transmit pulse.
P841 Long Shot Number
Enter the number of long shots to be fired (and results averaged) per transmit pulse.
This value is automatically altered by Maximum Process Speed (P003).
P842 Short Shot Frequency
Adjust the short shot transmit pulse frequency (in kHz).
This feature is automatically altered when Transducer (P004) is altered.
Note: These parameters are for Siemens Milltronics service personnel only.
Values
Range: 0 to 100
Preset: 1
Related
P841 Long Shot Number
P842 Short Shot Frequency
P844 Short Shot Width
P850 Short Shot Bias
P851 Short Shot Floor
P852 Short Shot Range
Values
Range: 0 to 200
Preset: 5
Altered By P003 Maximum Process Speed
Related
P840 Short Shot Number
P843 Long Shot Frequency
P845 Long Shot Width
Values Range: 10 to 60 kHz
Altered By •P004 Transducer
Related
P840 Short Shot Number
P844 Short Shot Width
P850 Short Shot Bias
P851 Short Shot Floor
P852 Short Shot Range