Industry Automation and Drive Technologies - SCE
TIA Training Document
Page 21 of 47 Module
E12
Status: 01/2010 Vision Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120
14. Then, drag the PROFINET IO System (100) module tier
<<?>>
toward the right, and from the
folder PROFINET IO add the SIMATIC VS100 module VS120 by dragging it to the tier.
If module VS120 should not be available for selection, it has to be added by a data carrier by
means of the menu “Options“ Install GSD files.
15. Double click on the inserted module and change the device name to VS120x120 and the IP
address to 192.168.0.120.
Przeglądanie stron 20