Engineer programming via the keypad
This information should be available from the receiving station and is used to
identify users each time a call is made to the ARC
Description of the Remote Alarm Receiving Centre
The communication protocol to be used (SIA, Contact ID, Fast Format)
The first number to be dialled to contact the ARC
The second number to be dialled to contact the ARC; the system only
attempts to contact the ARC on this number if the first contact number did
not successfully connect
The modem (primary or back-up) to be used to communicate with the ARC
14.10.5 REMOTE MAINTENANCE
1. Scroll to REMOTE MAINT.>ENABLE REMOTE MAINT
3. Toggle between ENABLED and DISABLED.
4. Select the desired programming option shown in the table below.
Remote Maintenance ID. Must match that at SPC Pro (1 - 999999 ).
Password for Remote Maintenance. Must match that at SPC Pro.
Incoming Connection Settings. You can enable IN IP ENABLE to
allow incoming IP connections from the Remote Maintenance
server. If not enabled, only modem connections are possible. Enter
the IN TCP/IP PORT on which the panel listens to incoming IP
connections from the Remote Maintenance server.
Outgoing Connection Settings. Choose how to make outgoing
connections to the Remote Maintenance server from the options
DISABLED, OVER MODEM or OVER IP.
1. Scroll to TEST and press SELECT.
2. Scroll to the desired programming option.
14.11.1 BELL TEST
To perform a bell test:
1. Scroll to TEST > BELL TEST.
2. Press SELECT.
When BELL TEST is selected, the following options available: EXTERNAL
BELLS, STROBE, INTERNAL BELLS and BUZZER. When each of these
options is selected, the device sounds to verify it is operating correctly.