Engineer programming via the keypad
X-BUS
84
Siemens AB
A6V10276959
Security Products
18.11.2011
14.5.3 KEYPADS/EXPANDERS/DOOR CONTROLLERS
NOTICE
You must upgrade to version 1.1 of firmware before adding door controllers. With
earlier firmware versions, the door controllers are seen by the panel as normal I/O
expanders and doors must be added manually.
14.5.3.1 LOCATE
To locate a keypad/expander/door controller:
1. Scroll to KEYPADS, EXPANDER or DOOR CONTROLLER and press
SELECT.
2. Scroll to LOCATE and press SELECT.
3. Scroll to the expander/keypad/door controller to be located and press SELECT.
The selected device beeps and the LED flashes allowing Engineer to locate
it.
4. Press BACK to exit.
Locate keypads using the same menus and following the keypad choice
instead of expander.
14.5.3.2 MONITOR
To obtain an overview of the keypads/expanders/door controller connected to the
system:
1. Scroll to KEYPADS, EXPANDER or DOOR CONTROLLER and press
SELECT.
2. Scroll to MONITOR and press SELECT.
3. Scroll to desired Monitor programming option.
4. Press SELECT.
A list of detected keypads/expanders is displayed.
5. Scroll through the list and press SELECT on preferred expander/keypad/door
controller.
Parameters and details, if applicable, are displayed for editing as shown in
the table below.
6. Press BACK to exit.
STATUS
Online or offline
S/N
Serial number (used to track and identify)
VER
Firmware version
POWER
Power parameters: real-time voltage and current readings