By adding a separate Alarm Receiving Centre (ARC) for each area defined on the
system and programming each area to report it’s own separate ARC receiver, the
system can approximate a multi-tenanted system in that a high degree of
autonomy is assigned to each area.
15.12.8 EDP Setup
The system has the facility to communicate information to the SPC Com server
remotely using Siemens ’s own protocol, the EDP (Enhanced Datagram Protocol).
By correctly configuring an EDP receiver on the system, it can be programmed to
automatically make data calls to the SPC Com server in a remote location
whenever events such as alarm activations, tampers, or arming/disarming occur.
The engineer can configure the system to make calls to the remote server via the
following routes:
PSTN (PSTN modem required)
GSM (GSM modem required)
Internet (Ethernet interface)
If using the PSTN network, ensure the PSTN modem is properly installed and
functioning correctly and that a functioning PSTN line is connected to the A, B
terminals on the PSTN modem.
If using the GSM network, ensure the GSM module is properly installed and
functioning correctly. An IP connection can be made across the internet to a server
with a fixed public IP address.
If an IP connection is required, ensure the Ethernet interface is correctly configured
(see page [➙ 116]) and that internet access is enabled at the router.
15.12.8.1 Adding an EDP Receiver