NCK alarms
06/2009 Overview of alarms
2-111
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
The macro definitions and cycle interfaces are also read in during the power-up procedure. If an error
occurs here, this is indicated by value = 4, or value = 5
6: Error creating 2 1/2 D protection zones during power up.
(Program) START:
Value
100: Error during synchronization preprocessing/main run
101: Error on selection of tool length compensation
102: Error on selection of transformation
103: Error on selection of synchronized spindle
104: Error on selection of work offset
Particularly when tool management is active, it is possible that a tool on the spindle or the toolholder
is disabled but still needs to be activated.
These tools are automatically activated on RESET. On START, machine data MD22562
$MC_TOOL_CHANGE_ERROR_MODE can be used to specify whether an alarm is to be generated
or an automatic bypass strategy selected.
If the parameter contains 3 values from 200 to 203, this means that an insufficient number of NC
blocks is available for NC block preparation on certain commands (ASUB start, overstore selection,
teach-in).
Remedy: Increase machine data MD28070 $MC_MM_NUM_BLOCKS_IN_PREP.
Reaction: Interpreter stop
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
If parameter %3= 0 -3:
If the alarm or alarms occur on RESET:
Check the settings of machine data MD20110 $MC_RESET_MODE_MASK,
MD20120 $MC_TOOL_RESET_VALUE, MD20121 $MC_TOOL_PRESEL_RESET_VALUE,
MD20122 $MC_TOOL_RESET_NAME (only if tool management is active),
MD20130 $MC_CUTTING_EDGE_RESET_VALUE, MD20132 $MC_SUMCORR_RESET_VALUE,
MD20126 $MC_TOOL_CARRIER_RESET_VALUE,
MD20150 $MC_GCODE_RESET_VALUES, MD20154 $MC_EXTERN_GCODE_RESET_VALUES,
MD20140 $MC_TRAFO_RESET_VALUE,
MD21330 $MC_COUPLE_RESET_MODE_1,
MD24002 $MC_CHBFRAME_RESET_MASK
If parameter %3= 100 - 104:
Check the setting of MD20112 $MC_START_MODE_MASK and the machine data specified under
'..._RESET_...'. If tool management is active, if necessary remove the tool stated in the associated
alarm from the toolholder/spindle and cancel the 'disabled' status.
If parameter %3= 4 or 5:
Check macro definitions in _N_DEF_DIR
Check cycle directories _N_CST_DIR and _N_CUS_DIR
If parameter %3= 6:
Alarm 18002 or 18003 was also issued. This alarm contains the number of the incorrectly defined pro-
tection zone and an identifier of what is incorrect about the protection zone. The system variables must
be appropriately corrected.
If Parameter %3= 200 bis 203:
Increase MD28070 $MC_MM_NUM_BLOCKS_IN_PREP.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14711 [Channel %1: ] Transformation selection not possible as axis %2 not
available
Parameters: %1 = Channel number
%2 = Axis name, spindle number
Definitions: Based on the configuration of machine data MD20110 $MC_RESET_MODE_MASK and MD20140
$MC_TRAFO_RESET_VALUE, a transformation shall be selected by performing a reset or control
ramp-up. However, this is not possible as axis %2 required for this is not available. Possible reason:
The axis was occupied by another channel or the PLC.
Reaction: Interface signals are set.