Cycle alarms
06/2009 Overview of alarms
2-239
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Remedy: Check parameter _PROTVAL[].
61362 [Channel %1: ] Block %2: Cycle118: No. of values too large
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE118.
4th parameter for CYCLE118 is larger than 10.
Remedy: Reduce the 4th parameter (PAR4) of CYCLE118.
61363 [Channel %1: ] Block %2: Max. no. of value lines for recording exceeded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Maximum number of value lines exceeded.
Alarm triggerd by following cycle: CYCLE105.
Remedy: Reduce the number of value lines.
Check parameter _PROTFORM[4].
61364 [Channel %1: ] Block %2: Check distance from measuring point 1 to
measuring point2
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE998.
Parameter _ID is <= 0.
Remedy: Check parameter _ID.
61365 [Channel %1: ] Block %2: Check circular feed
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE979.
Parameter _RF is <= 0.
Remedy: Check parameter _RF.
61366 [Channel %1: ] Block %2: Direction of rotation for tool measurement with
rotating spindle not specified in _CM[5]
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE971.
Permissible values for data field _CM[5] in GUD6 block are 3 (corresponds to M3) or 4 (corresponds
to M4).
Remedy: Check parameter _CM[5] in GUD6.
61367 [Channel %1: ] Block %2: Parameters _SETV[0...3] or _SETV[4...7] are
identical
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE961.
Remedy: Specify different positions for the relevant points of _SETV[0...7] .
61368 [Channel %1: ] Block %2: Straights through parameter _SETV[0...3] or
_SETV[4...7]do not intersect
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE961.
Remedy: Specify different positions for the relevant points of _SETV[0...7] .
61369 [Channel %1: ] Block %2: Position of corner not clearly definable, check
parameter (_SETV[0...7])
Parameters: %1 = Channel number
%2 = Block number, label channel number