Overview of alarms 06/2009
NCK alarms
2-22
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
4112 Servo cycle changed to %1 ms
Parameters: %1 = String (new servo cycle time)
Definitions: For PROFIBUS/PROFINET only:
MD10060 $POSCTRL_SYSCLOCK_TIME_RATIO has been modified because of the modified DP
cycle in the SDB (MD10050 $SYSCLOCK_CYCLE_TIME).
Reaction: Alarm display.
Remedy: MD10060 $MN_POSCTRL_SYSCLOCK_TIME_RATIO RATIO has been modified.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4113 Sysclock cycle changed to %1 ms
Parameters: %1 = String (new PLC cycle time)
Definitions: For PROFIBUS/PROFINET only:
MD10050 $SYSCLOCK_CYCLE_TIME has been modified because of the modified DP cycle in the
SDB.
Reaction: Alarm display.
Remedy: MD10050 $MN_SYSCLOCK_CYCLE_TIME has been modified.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4114 Error in DP cycle of the SDB
Parameters: %1 = String (new PLC cycle time)
Definitions: For PROFIBUS/PROFINET only:
The DP cycle in the SDB contains an error and cannot be set. The default value of
MD10050$MN_SYSCLOCK_CYCLE_TIME is set.
Reaction: Alarm display.
Remedy: Correct the SDB
Program Con-
tinuation:
Switch control OFF - ON.
4150 [Channel %1: ] Invalid M function subprogram call configured
Parameters: %1 = Channel number
Definitions: MD10715 $MN_M_NO_FCT_CYCLE[n] or MD10718 $MN_M_NO_FCT_CYCLE_PAR contains
invalid configuration data: An M function, which is occupied by the system and cannot be replaced by
a subprogram call has been specified in MD10715 $MN_M_NO_FCT_CYCLE[n] for the configuration
of the subprogram call via M function:
- M0 to M5,
- M17, M30,
- M19, M40 to M45,
- M function for selecting spindle/axis mode according to MD20094
$MC_SPIND_RIGID_TAPPING_M_NR (default: M70),
- M functions for nibbling/punching as configured in MD26008 $MC_NIBBLE_PUNCH_CODE if acti-
vated by MD26012 $MC_PUNCHNIB_ACTIVATION.
- Also M96 to M99 for applied external language (MD18800 $MN_MM_EXTERN_LANGUAGE).
MD10718 $MN_M_NO_FCT_CYCLE_PAR contains an invalid array index of MD10715
$MN_M_NO_FCT_CYCLE[n]. Currently, the values 0 to 9 are permissible. The affected machine data
is reset to the default value -1. This deactivates the function.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Configure an M function in MD10715 $MN_M_NO_FCT_CYCLE[n] that is not occupied by the sys-
tem, or configure a permissible array index in MD10718 $MN_M_NO_FCT_CYCLE_PAR.
Program Con-
tinuation:
Switch control OFF - ON.
Komentarze do niniejszej Instrukcji