Overview of alarms 06/2009
Cycle alarms
2-226
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Alarm triggered by following cycle: CYCLE61
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Select another direction of machining.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61267 [Channel %1: ] Block %2: Plane infeed too large, residual corners remain
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In face milling, the plane infeed must not exceed 85%.
Alarm triggered by following cycle: CYCLE61
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Select a smaller plane infeed, as otherwise residual corners will be left over.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61268 [Channel %1: ] Block %2: Illegal machining direction, residual corners
are left over.
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In face milling, the machining direction does not match the selected delimitations.
Alarm triggered by following cycle: CYCLE61.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The machining direction must be selected to match the delimitations.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61269 [Channel %1: ] Block %2: External tool diameter too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Incorrect tool definition.
Alarm triggered by following cycle: CYCLE61.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check angle and diameter of the tool used.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61270 [Channel %1: ] Block %2: Chamfer width too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Chamfer width selected too small.
Alarm triggered by the following cycles: E_SP_CHA, F_SP_CHA.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Increase the chamfer width.