DPC31 HW
SchnittStellenCenter
DPC31 HW Description
Version V1.0 Page 13
Copyright (C) Siemens AG 2000. All rights reserved. 12/00
Address Name Meaning (read access!)
0000h Int-Req-Reg
7..0
Interrupt Controller Register
0001h Int-Req-Reg
15..8
0002h Int-Req-Reg
23..16
0003h Int-Req-Reg
28..24
0004h Int-Reg
7..0
0005h Int-Reg
15..8
0006h Int-Reg
23..16
0007h Int-Reg
28..24
0008h
... Reserved
000Fh
0010h C31_Control Register
7..0
Refer to Chapter 4
0011h
... Reserved
001Fh
0020h SSC_Rcv-Buf
7..0
Receive buffer of the SSC interface
0021h SSC_Sts-Reg
3..0
Status register of the SSC interface
0022h SSC_Ctrl1-Reg
7..0
Control register of the SSC interface
0023h SSC_Ctrl2-Reg
2..0
Control register of the SSC interface
0024h
... Reserved
002Fh
0030h User_SSA_Ok Cmd
1..0
The user acknowledges the user SSA data of an SSA message
positively
0031h User_Prm_Ok Cmd
1..0
The user acknowledges the user parameter assignment data of a
prm message positively
0032h User_Prm_Not_Ok Cmd
1..0
The user acknowledges the user parameter assignment data of a
prm message negatively
0033h Reserved
0034h
0035h User_Cfg_Ok Cmd
1..0
The user acknowledges the configuring data of a CfG message
positively
0036h User_Cfg_Not_Ok-Cmd
1..0
The user acknowledges the configuring data of a Cfg message
negatively
0037h User_Diag_Read-Cmd The user makes a new diag buffer available
0038h User_Get_Cfg_Read-Cmd The user makes a new Get_Cfg buffer available
0039h User_New_Din-Cmd
1..0
The user makes a new Din buffer available
003Ah User_Din_Puffer-State
7..0
The user reads the current Din buffer assignment
003Bh User_New_Dout-Cmd
3..0
The user fetches the last Dout buffer from the N state
003Ch User_Dout_Puffer-State
7..0
The user reads the current Dout buffer assignment
003Dh
... Reserved
07FFh
Table 3.2-1:
Assignment of the Internal Register Cells for READ