DPC31 HW
SchnittStellenCenter
DPC31 HW Description
Version V1.0 Page 19
Copyright (C) Siemens AG 2000. All rights reserved. 12/00
=1 The ‘New_GC_Command Int’ is generated for each receipt of a GC
message.
XAsyn/Syn: Setting the bus physics
=0 Asynchronous physics; the work clock pulse is fixed at 48 MHz (via PLL)
Baudrate: 9.6 kBd to 12 MBd (basic setting)
=1 Synchronous physics; the work clock pulse can be set: 2, 4, 8 or 16 MHz
Baudrate: fixed at 31.25 kBd
En_Change_Cfg_Buffer: Enable of the
buffer exchange (User_Cfg_Buffer for MAC_GCfg_Rbuffer)
=0 The buffers won’t be exchanged.
=1 With ‘User_Cfg_Ok Cmd’, the above-mentioned buffers are exchanged. The
exchange is confirmed with the interrupt ‘Get_Cfg_Buffer_Changed’ .
Syn_Clkin
1..0
: Setting the external clock pulse supply at Pin XTAL1_CLK (not via PLL). The internal
C31 processes with half the clock frequency!
=00 External clock = 2 MHz ⇒ Baudrates: 31.25 (not released!)
=01 External clock = 4 MHz ⇒ Baudrates: 31.25
=10 External clock = 8 MHz ⇒ Baudrates: 31.25
=11 External clock = 16 MHz ⇒ Baudrates: 31.25
Preamble
1..0
: For the syn. physics, the preamble length is parameterized in number of bytes.
=00 ⇒ 1 byte
=01 ⇒ 2 bytes
=10 ⇒ 4 bytes
=11 ⇒ 8 bytes