NCK alarms/ISO alarms
06/2007 Overview of alarms
2-119
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
14028 Channel %1 block %2 motion-synchronous action: Technology cycle
programmed with too many parameters
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Maximum number of transfer parameters for one technology cycle exceeded.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Change technology cycle
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14030 Channel %1 block %2 combine OSCILL and POSP during oscillation with
infeedmotion
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: When oscillating controlled by synchronized actions, the assignment of oscillating and infeed axis
(OSCILL) as well as the definition of the infeed (POSP) must be carried out in one NC block.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14033 Channel %1 block %2 involute: no end point programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No end point was programmed for the involute. This is either possible via direct programming with the
geometry axis identifiers or by specifying the angle between start and end vector.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14034 Channel %1 block %2 involute: angle of rotation too large
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: With programming of the angle of rotation (with AR) for involute interpolation, the maximum program-
mable angle of rotation is limited if the involute is moving towards the basic circle. The maximum value
is reached if the involute touches the basic circle. With
MD_INVOLUTE_AUTO_ANGLE_RESTRICTION = TRUE, each angle is accepted without an alarm;
if necessary, the angle is automatically limited during interpolation.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14035 Channel %1 block %2 involute: start point invalid
Parameters: %1 = Channel number
%2 = Block number, label