Cycle alarms
06/2007 Overview of alarms
2-307
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61357 Channel %1 Block %2: No resources free
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
Not enough NC memory space available.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Delete the files.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61369 Channel %1 block %2: Position of corner not clearly definable, check
parameter (_SETV[0...7])
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE961.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Define P1 and P2 or P3 and P4 in a way that the intersection of the straights determined by these
points is outside the sections formed by P1 and P2 or P3 and P4.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61501 Channel %1 block %2: Simulation is active
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycles: all grinding cycles
Remedy: Reset simulation
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61502 Channel %1 block %2: No tool offset active
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycles: all grinding cycles
Remedy: A tool number must be programmed
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61503 Channel %1 block %2: tool nose radius compensation left or right
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycles: CYCLE410, CYCLE411, CYCLE412,
CYCLE413, CYCLE414, CYCLE415, CYCLE416, CYCLE420
Remedy: A tool offset value has to be programmed
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61504 Channel %1 block %2: _KNG incorrect for setup
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program