61265 Channel %1 block %2: Too many restrictions, use rectangular pocket
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In face milling a maximum of only 3 sides can be delimited.
Alarm triggered by following cycle: CYCLE61
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Use pocket cycle.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61266 Channel %1 Block %2: Illegal machining direction
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In face milling, the delimitations and the direction of machining do not match.
Alarm triggered by following cycle: CYCLE61
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Select another direction of machining.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61267 Channel %1 Block %2: Plane infeed too large, residual corners remain
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In face milling, the plane infeed must not exceed 85%.
Alarm triggered by following cycle: CYCLE61
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Select a smaller plane infeed, as otherwise residual corners will be left over.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61268 Channel %1 block %2: Illegal machining direction, residual corners are
left over.
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In face milling, the machining direction does not match the selected delimitations.
Alarm triggered by following cycle: CYCLE61.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The machining direction must be selected to match the delimitations.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program