
Cycle alarms
06/2007 Overview of alarms
2-275
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61101 Channel %1 block %2: Reference plane incorrectly defined
Parameters:
Definitions: Source (cycle):
CYCLE71
CYCLE22
CYCLE81 to CYCLE88
CYCLE840
CYCLE375T
SLOT1, SLOT2
POCKET3, POCKET4
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Either different values must be entered for the reference plane and the retraction plane if they are rel-
ative values or an absolute value must be entered for the depth.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61102 Channel %1 block %2: No spindle direction programmed
Parameters:
Definitions: Source (cycle):
CYCLE86
CYCLE88
CYCLE840
CYCLE370T to CYCLE374T, CYCLE376T
CYCLE383T to CYCLE385T
CYCLE381M, CYCLE383M, CYCLE384M, CYCLE387M
POCKET3, POCKET4
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Parameter SDIR (or SDR in CYCLE840) must be programmed.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61103 Channel %1 block %2: Number of holes is zero
Parameters:
Definitions: Source (cycle):
HOLES1
HOLES2
Remedy: No value has been programmed for the number of holes.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61104 Channel %1 block %2: Contour violation of grooves
Parameters:
Definitions: Source (cycle):
SLOT1
SLOT2
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Errors in parameterization of milling pattern in those parameters which define the position and shape
of slots/longitudinal holes on a circle
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Komentarze do niniejszej Instrukcji